GEORG FISCHER
pH and ORP electrodes are general purpose sensors ideal for a wide range of applications. These feature a patented reference design and uses the unique foul-proof patented DryLoc® connector. The large area PE reference junction and pathway is constructed to increase the total reference eff ectiveness and ensures long service life.
Â
The DryLoc® connector with corrosion resistant gold plated contacts readily connects the sensor to the mating 2751 pH/ORP Smart Sensor Electronics or the 2760 Preamplifi er. The robust PPS threaded sensor body and choice of fl at pH, bulb pH, or fl at ORP sensing elements allows a broad range of chemical and mechanical compatibility for a wide variety of applications.
Â
There are two optional pH sensing versions available, HF and LC. The HF version is for applications where traces of hydrofl uoric acid (2% or less) will attack standard pH glass. The LC version can be used for low conductivity fl uids 20 - 100 µS/cm nominal and below 20 µS/cm when mounted under controlled conditions.
Â
The quick temperature response is available in either a Pt1000 or 3 KΩ temperature sensor and allows compatibility with all pH/ORP instruments. The 2724- 2726 electrodes incorporate ¾ inch NPT or ISO 7/1-R 3/4 threads for installing into GF standard pipe-tees. They can also be mounted directly into standard fi ttings, DN15 to DN100 (½ to 4 inch)
pH and ORP electrodes are general purpose sensors ideal for a wide range of applications. These feature a patented reference design and uses the unique foul-proof patented DryLoc® connector. The large area PE reference junction and pathway is constructed to increase the total reference eff ectiveness and ensures long service life.
Â
The DryLoc® connector with corrosion resistant gold plated contacts readily connects the sensor to the mating 2751 pH/ORP Smart Sensor Electronics or the 2760 Preamplifi er. The robust PPS threaded sensor body and choice of fl at pH, bulb pH, or fl at ORP sensing elements allows a broad range of chemical and mechanical compatibility for a wide variety of applications.
Â
There are two optional pH sensing versions available, HF and LC. The HF version is for applications where traces of hydrofl uoric acid (2% or less) will attack standard pH glass. The LC version can be used for low conductivity fl uids 20 - 100 µS/cm nominal and below 20 µS/cm when mounted under controlled conditions.
Â
The quick temperature response is available in either a Pt1000 or 3 KΩ temperature sensor and allows compatibility with all pH/ORP instruments. The 2724- 2726 electrodes incorporate ¾ inch NPT or ISO 7/1-R 3/4 threads for installing into GF standard pipe-tees. They can also be mounted directly into standard fi ttings, DN15 to DN100 (½ to 4 inch)
OEM is pleased to announce a range of hydrogen-approved mechanical pressure switches, by Suco! Today, hydrogen plays a key role in climate-neutral energy generation and storage.
OEM Automatic proudly welcomes the addition of WIKA to its lineup. Wika Force brings a new dimension to the realm of force measurement. The integration of WIKA into the OEM Automatic pressure and flow range represents a significant advancement in force measurement technology!
Georg Fischer is a globally renowned provider of process automation systems and solutions for various industries. Join us as we delve into the advantages and opportunities that this new addition brings to you.
Using hydrogen as a source of energy is an emerging market. ESI have a selected range of pressure sensors that are hydrogen-compatible.
Automated machinery in the process and packaging industries is constantly developing. Find out how we can help to automate process and packaging machinery at OEM.
Zoedale Ltd has been fully integrated into OEM Automatic for a few months now, see what benefits this integration can bring to you.
|
|
|
|
|
||
---|---|---|---|---|---|---|
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
Parts | Price | ||
---|---|---|---|
![]()
2724 - pH electrode, PT1000, flat tip, 3/4in NPT thread, use with 2751
Art:
159001545
Copied
|
| ||
![]()
2724 - pH electrode, PT1000, flat tip, 3/4in ISO thread, use with 2751
Art:
159001546
Copied
|
| ||
![]()
2725 - ORP electrode, flat tip, 3/4in NPT thread, use with 2751
Art:
159001561
Copied
|
| ||
![]()
2725 - ORP electrode, flat tip, 3/4in ISO thread, use with 2751
Art:
159001562
Copied
|
| ||
![]()
2726 - pH electrode, PT1000, bulb tip, 3/4in NPT thread, use with 2751
Art:
159001553
Copied
|
| ||
![]()
2726 - pH electrode, PT1000, bulb tip, 3/4in ISO thread, use with 2751
Art:
159001554
Copied
|
| ||
![]()
2726 - pH electrode, PT1000, bulb tip, 3/4in NPT thread, HF resistant, use with 2751
Art:
159001549
Copied
|
| ||
2726 - pH electrode, PT1000, bulb tip, 3/4in ISO thread, HF resistant, use with 2751
Art:
159001550
Copied
|
| ||
2726 - pH electrode, PT1000, bulb tip, 3/4in NPT thread, low conductivity, use with 2751
Art:
159001557
Copied
|
| ||
![]()
2726 - pH electrode, PT1000, bulb tip, 3/4in ISO thread, low conductivity, use with 2751
Art:
159001558
Copied
|
|
Select a variant in the list