ANDERSON NEGELE
The Anderson-Negele FWS/FWA is a flow switch with an optional 4-20mA or frequency output (changeable on the sensor) to enable it to give not only a PNP switch point output but also a volumetric output when required (+/- 10% full scale accuracy on output). Using the ultrasonic Doppler principal for flow detection means that the FWS and FWA are completely independent of system temperature fluctuation, media conductivity and system pressure. There is also an LED to indicate the state of the switched output, which is freely scalable across the flow range of the sensor.
This product is ideal for dry pump running detection due to its fast reaction time, use in CIP/SIP systems with a high temperature version available as well, if required. The sensor is designed to operate at 140°C for 120 minutes continuously without issue and all media contacting materials are FDA compatible. An ideal lower cost FDA approved sensor where using a more expensive technology isn’t necessary and switching or “rough” flow volumes are all that is required.
Application Examples:
| Approvals | 3-A, FDA |
|---|---|
| Area of apllication | Food |
| Flow area max | 2.5 m/s |
| Flow area min | 0.1 m/s |
| IP class | IP67, IP69K |
| Material of sensor housing | Stainless steel 1.4305 |
| Material of wetted parts | PEEK, Stainless steel 316L |
| Pressure range max | 10 bar |
| Surface finish | 0.8 µm Ra |
|---|---|
| Temperature ambient from | -20 °C |
| Temperature ambient to | 60 °C |
| Temperature of media from | 0 °C |
| Temperature of media to | 100 °C |
| Weight | 485 g |
The Anderson-Negele FWS/FWA is a flow switch with an optional 4-20mA or frequency output (changeable on the sensor) to enable it to give not only a PNP switch point output but also a volumetric output when required (+/- 10% full scale accuracy on output). Using the ultrasonic Doppler principal for flow detection means that the FWS and FWA are completely independent of system temperature fluctuation, media conductivity and system pressure. There is also an LED to indicate the state of the switched output, which is freely scalable across the flow range of the sensor.
This product is ideal for dry pump running detection due to its fast reaction time, use in CIP/SIP systems with a high temperature version available as well, if required. The sensor is designed to operate at 140°C for 120 minutes continuously without issue and all media contacting materials are FDA compatible. An ideal lower cost FDA approved sensor where using a more expensive technology isn’t necessary and switching or “rough” flow volumes are all that is required.
Application Examples:
Please refer to the image below for ordering information.
You already added this product. Choose whether to increase quantity on the existing row or add the product as a new row.
OEM Automatic is pleased to welcome Mike Howells as Product Manager with the Pressure & Flow Division. With nearly 30 years of experience across the automation, process and valve industries, Mike brings a wealth of technical knowledge and product expertise to the business.
Robotics has revolutionised industry, enabling efficiency, higher production capacity and increased safety. For a robot solution to function optimally, the right components are required.
Whether you're looking to upgrade your current solution or secure a more robust float switch for your next project, Taurus delivers performance you can count on.
In this article, our application experts explain why hydrostatic level probes appear to lie, the most common failures, and how OEM, working with Aplisens, can help engineers prevent them.
A hydrostatic level probe measures liquid level indirectly, by sensing pressure at a known depth. When the application is suitable and the installation is done properly, hydrostatic level probes offer several clear benefits.
OEM Automatics water and wastewater application specialists have gathered all our solutions in one place. Our products are used in everything from small municipal water works to larger regional plants.