IDEM

IDEM - Non-contact safety switch SMC-F

A coded magnetic switch made of stainless steel with a small size and high tolerance, which is ideally suited for applications in the food and pharmaceutical industries. The switch has a standard spacing of fixing holes - 22 mm and is resistant to pressure washing. Mounting screws from the bottom makes the switch ideal for demanding food applications.

Read more
  • Stainless steel housing
  • Mounting screws from the bottom
  • For demanding food applications
  • Switching range - 14 mm
  • No dedicated controller

Selected variant

Available in several variants

Selected variant

Technical data

Approvals ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508
Cable length 2 m
Cable type PVC 6 or 8 core 6mm OD Conductors 0.25mm²
Coding Coded magnetic actuation
Conductor size 0.25 mm²
Contact rating max 24Vdc 0.2A
Contacts 2NC
Housing material Stainless steel 316
Integrated LED indication Yes
IP class IP69K, IP67
Mounting 2 x M4
MTTFd 866 years
Operating temperature -25..105°C
PFHd 8.71 X 10⁻¹¹
PL e acc. ISO13849-1
Recommended mounting gap 5 mm
SIL 3 acc. EN62061
Switching current min 10Vdc 1mA
Switching distance Sao 10mm close, Sar 20mm open
Switching frequency max 1.0Hz maximum

Product description

A coded magnetic switch made of stainless steel with a small size and high tolerance, which is ideally suited for applications in the food and pharmaceutical industries. The switch has a standard spacing of fixing holes - 22 mm and is resistant to pressure washing. Mounting screws from the bottom makes the switch ideal for demanding food applications.

Accessories

Related products

Add product as a new cart row

You already added this product. Choose whether to increase quantity on the existing row or add the product as a new row.

Related

Parts Approvals Cable length Contacts Operating temperature PL SIL Switching distance Price
ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508
2 m
2NC
-25..105°C
e acc. ISO13849-1
3 acc. EN62061
ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508
5 m
2NC
-25..105°C
e acc. ISO13849-1
3 acc. EN62061
ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508
10 m
2NC
-25..105°C
e acc. ISO13849-1
3 acc. EN62061
ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508
0.25 m
2NC
-25..105°C
e acc. ISO13849-1
3 acc. EN62061
ISO 13849-1, ISO 14119, EN60204-1, EN62061, EN60947-5-1, CE, cULus, TÜV, UL 508
2 m
2NC 1NO
-25°C - 105°C
up to PLe acc. ISO13849-1
14 mm
ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508
5 m
2NC 1NO
-25..105°C
e acc. ISO13849-1
3 acc. EN62061
ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508
10 m
2NC 1NO
-25..105°C
e acc. ISO13849-1
3 acc. EN62061
ISO 13849-1, ISO 14119, EN60204-1, EN62061, EN60947-5-1, CE, cULus, TÜV, UL 508
0.25 m
2NC 1NO
-25°C - 105°C
up to PLe acc. ISO13849-1
14 mm
ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508
2 m
3NC
-25..105°C
e acc. ISO13849-1
3 acc. EN62061
ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508
5 m
3NC
-25..105°C
e acc. ISO13849-1
3 acc. EN62061
ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508
10 m
3NC
-25..105°C
e acc. ISO13849-1
3 acc. EN62061
ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508
0.25 m
3NC
-25..105°C
e acc. ISO13849-1
3 acc. EN62061