TAKEX
The F80 amplifier has a large, clear display which facilitates the reading of incoming light. On this amplifier, you can choose whether you want long detection distances or a fast reaction time. Reading takes place with Teach In via the green button on the amplifier. You also have the option of manually changing the value on the amplifier to the level at which you want your output signal.
| Approvals | CE |
|---|---|
| Electrical connection | Embedded 2m cable |
| Function | Dark on / Light on |
| IP class | IP40 |
| Light type | Red LED |
| Light/dark switching | Yes |
| Output | PNP |
| Output current max | 0.1 A |
| Photocell technology | Fiber amblified |
|---|---|
| Power consumption max | 0.032 A |
| Reaction time | 0.19 ms |
| Temperature operational max | 55 °C |
| Temperature operational min | -25 °C |
| Voltage dc max | 24 V |
| Voltage dc min | 12 V |
Now let the object pass
With an object. Hold down the green button until you see SET.
Hold down the green button for 5 sec.
When Long or H-SP is displayed, release the button.
Without an object, hold down the green button for 3 sec
until you see SET and the green LED flashes. Release the button.
Hold down the green button for 5 sec.
When Long or H-SP is displayed, release the button.
With an object. Hold down the green button until you see SET.
With an object. Hold down the green button until you see SET.
Hold down the green button for a further 3 sec.
Release the button when you see Auto and the outer LEDs flash.
Without an object, hold down the green button for 3 sec until you see
SET and the green LED flashes. Release the button.
The F80 amplifier has a large, clear display which facilitates the reading of incoming light. On this amplifier, you can choose whether you want long detection distances or a fast reaction time. Reading takes place with Teach In via the green button on the amplifier. You also have the option of manually changing the value on the amplifier to the level at which you want your output signal.
We are pleased to announce that OEM Automatic Ltd has acquired Motion29 Ltd. Bringing together the expertise, products, and services of both organisations under both the OEM and Motion29 brands, strengthening our overall offering.
Discover how fault masking is compromising the safety of your workplace and find out how OEM Automatic can help you to prevent it completely. Creating a safe and secure work environment.
Learn more about Inxpect radar systems. The worlds first SIL 2/PL d certified, radar-based safety system for use around hazardous machinery.
Whether you're working with opaque materials or transparent items like glass or plastic, these sensors deliver reliable performance across a wide range of applications.
OEM Automatics Safety Experts guide you through the process of setting up your light curtains & barriers, to protect your people and equipment.
Ultra fast-acting fuse links engineered specifically to shield delicate semiconductor devices.