DUELCO

Duelco SSO-2010 Standstill monitor

The SSO-2010 can be used for standstill detection on all 3-phase, single phase and DC motors that generate a voltage when freewheeling.

 

Read more
  • Safety Category 4 (PLe)
  • 3 NO safety outputs + 1 NC safety output
  • 2 semiconductor monitoring outputs
  • 1 NO monitoring output
  • Delayed outputs (0 - 6 sec.)

Selected variant

Duelco SSO-2010 Standstill monitor

SSO-2010 Standstill Monitoring Relay 24Vdc

Art:

Selected variant

Technical data

Approvals BG, CE
Contact current max 5 A AC/DC
Contact voltage max 250 V AC/24 V DC
In compliance with EMC, LVD, MD
IP class connection IP20
IP class housing IP40
Motor voltage max 690 V
PL e
Power consumption 3 W
Safety category 4
Safety outputs NO 3
Signal output NC 1
Supply voltage 24 V DC
Temperature operational max 55 °C
Temperature operational min -25 °C
Tolerance ±10 %