• black icon of a bullhorn 30 years industry experience
  • black icon of three cubes Over 8,000 products in stock
  • Black icon of a clock Order by 16:00 and receive the next working day
IDEM

IDEM

IDEM Die-cast safety limit switches HLM

  • Heavy duty die-cast bodies (red)
  • Positive opening NC safety contact
  • High mechanical life over 5,000,000 cycles
  • Industry standard mounting
  • Large choice of actuator heads

Product description

IDEM’s HLM range of heavy duty Die Cast Safety Limit Switches have been designed to be mounted for position sensing of moving applications e.g. guard doors, conveyors, machine beds and elevators. They are available with an extensive range of actuator heads and can be supplied with either slow break or snap action contacts.

 

Operation

 

Operation of IDEM Safety Limit Switches is achieved by a sliding actuation of the moving object to cause deflection of the switch plungers, rollers or levers.

 

For safety applications it is important that the moving object does not pass completely over the switch actuators so as to either cause damage to the actuator or allow it to return to its original position.

Part numbers

Parts Price Actuator Annual usage Approvals ATEX approved Conduit entry Contacts Mechanical reliability B10d MTTFd Operating temperature
Short Roller Lever 8 cylcles per hour/24 hours per day/365 days ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 No M20 2NC 2NO 2.5x10⁶ operations at 100mA load 356 Years -25C +80C
Short Roller Lever 8 cylcles per hour/24 hours per day/365 days ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 No M20 2NC 2NO 2.5x10⁶ operations at 100mA load 356 Years -25C +80C
Short Roller Lever 8 cylcles per hour/24 hours per day/365 days ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 No 1/2"NPT 2NC 2NO 2.5x10⁶ operations at 100mA load 356 Years -25C +80C
Short Roller Lever 8 cylcles per hour/24 hours per day/365 days ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 No QC M23 2NC 2NO 2.5x10⁶ operations at 100mA load 356 Years -25C +80C
Short Roller Lever 8 cylcles per hour/24 hours per day/365 days ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 No M20 3 NC 1 NO 2.5x10⁶ operations at 100mA load 356 Years -25C +80C
Short Roller Lever 8 cylcles per hour/24 hours per day/365 days ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 No M20 3 NC 1 NO 2.5x10⁶ operations at 100mA load 356 Years -25C +80C
Short Roller Lever 8 cylcles per hour/24 hours per day/365 days ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 No 1/2"NPT 3 NC 1 NO 2.5x10⁶ operations at 100mA load 356 Years -25C +80C
Short Roller Lever 8 cylcles per hour/24 hours per day/365 days ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 No QC M23 3 NC 1 NO 2.5x10⁶ operations at 100mA load 356 Years -25C +80C
Short Roller Lever 8 cylcles per hour/24 hours per day/365 days ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 No M20 4NC 2.5x10⁶ operations at 100mA load 356 Years -25C +80C
Short Roller Lever 8 cylcles per hour/24 hours per day/365 days ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 No 1/2"NPT 4NC 2.5x10⁶ operations at 100mA load 356 Years -25C +80C
Short Roller Lever 8 cylcles per hour/24 hours per day/365 days ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 No QC M23 4NC 2.5x10⁶ operations at 100mA load 356 Years -25C +80C
Short Roller Lever 8 cylcles per hour/24 hours per day/365 days ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 No M20 1NC 1NO 2.5x10⁶ operations at 100mA load 356 Years -25C +80C
Short Roller Lever 8 cylcles per hour/24 hours per day/365 days ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 No 1/2"NPT 1NC 1NO 2.5x10⁶ operations at 100mA load 356 Years -25C +80C
Short Roller Lever 8 cylcles per hour/24 hours per day/365 days ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 No QC M23 1NC 1NO 2.5x10⁶ operations at 100mA load 356 Years -25C +80C
Short Roller Lever 8 cylcles per hour/24 hours per day/365 days ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 Yes 3m 4 core Ex 1NC 1NO 2.5x10⁶ operations at 100mA load 356 Years -25C +80C
Short Roller Lever 8 cylcles per hour/24 hours per day/365 days ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 Yes 3m 4 core Ex 2NC 2.5x10⁶ operations at 100mA load 356 Years -25C +80C
Short Roller Lever 8 cylcles per hour/24 hours per day/365 days ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 Yes 3m 8 core Ex 2NC 2NO 2.5x10⁶ operations at 100mA load 356 Years -25C +80C
Roller Plunger 8 cylcles per hour/24 hours per day/365 days ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 No M20 2NC 2NO 2.5x10⁶ operations at 100mA load 356 Years -25C +80C
Roller Plunger 8 cylcles per hour/24 hours per day/365 days ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 No M20 2NC 2NO 2.5x10⁶ operations at 100mA load 356 Years -25C +80C
Roller Plunger 8 cylcles per hour/24 hours per day/365 days ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 No 1/2"NPT 2NC 2NO 2.5x10⁶ operations at 100mA load 356 Years -25C +80C
Roller Plunger 8 cylcles per hour/24 hours per day/365 days ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 No QC M23 2NC 2NO 2.5x10⁶ operations at 100mA load 356 Years -25C +80C
Roller Plunger 8 cylcles per hour/24 hours per day/365 days ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 No M20 3 NC 1 NO 2.5x10⁶ operations at 100mA load 356 Years -25C +80C
Roller Plunger 8 cylcles per hour/24 hours per day/365 days ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 No 1/2"NPT 3 NC 1 NO 2.5x10⁶ operations at 100mA load 356 Years -25C +80C
Roller Plunger 8 cylcles per hour/24 hours per day/365 days ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 No QC M23 3 NC 1 NO 2.5x10⁶ operations at 100mA load 356 Years -25C +80C
Roller Plunger 8 cylcles per hour/24 hours per day/365 days ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 No M20 4NC 2.5x10⁶ operations at 100mA load 356 Years -25C +80C
Roller Plunger 8 cylcles per hour/24 hours per day/365 days ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 No 1/2"NPT 4NC 2.5x10⁶ operations at 100mA load 356 Years -25C +80C
Roller Plunger 8 cylcles per hour/24 hours per day/365 days ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 No QC M23 4NC 2.5x10⁶ operations at 100mA load 356 Years -25C +80C
Roller Plunger 8 cylcles per hour/24 hours per day/365 days ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 No M20 1NC 1NO 2.5x10⁶ operations at 100mA load 356 Years -25C +80C
Roller Plunger 8 cylcles per hour/24 hours per day/365 days ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 No 1/2"NPT 1NC 1NO 2.5x10⁶ operations at 100mA load 356 Years -25C +80C
Roller Plunger 8 cylcles per hour/24 hours per day/365 days ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 No QC M23 1NC 1NO 2.5x10⁶ operations at 100mA load 356 Years -25C +80C
Roller Plunger 8 cylcles per hour/24 hours per day/365 days ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 Yes 3m 4 core Ex 1NC 1NO 2.5x10⁶ operations at 100mA load 356 Years -25C +80C
Roller Plunger 8 cylcles per hour/24 hours per day/365 days ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 Yes 3m 4 core Ex 2NC 2.5x10⁶ operations at 100mA load 356 Years -25C +80C
Roller Plunger 8 cylcles per hour/24 hours per day/365 days ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 Yes 3m 8 core Ex 2NC 2NO 2.5x10⁶ operations at 100mA load 356 Years -25C +80C
Pin Plunger 8 cylcles per hour/24 hours per day/365 days ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 No M20 2NC 2NO 2.5x10⁶ operations at 100mA load 356 Years -25C +80C
Pin Plunger 8 cylcles per hour/24 hours per day/365 days ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 No 1/2"NPT 2NC 2NO 2.5x10⁶ operations at 100mA load 356 Years -25C +80C
Pin Plunger 8 cylcles per hour/24 hours per day/365 days ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 No QC M23 2NC 2NO 2.5x10⁶ operations at 100mA load 356 Years -25C +80C
Pin Plunger 8 cylcles per hour/24 hours per day/365 days ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 No M20 3 NC 1 NO 2.5x10⁶ operations at 100mA load 356 Years -25C +80C
Pin Plunger 8 cylcles per hour/24 hours per day/365 days ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 No 1/2"NPT 3 NC 1 NO 2.5x10⁶ operations at 100mA load 356 Years -25C +80C
Pin Plunger 8 cylcles per hour/24 hours per day/365 days ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 No QC M23 3 NC 1 NO 2.5x10⁶ operations at 100mA load 356 Years -25C +80C
Pin Plunger 8 cylcles per hour/24 hours per day/365 days ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 No M20 4NC 2.5x10⁶ operations at 100mA load 356 Years -25C +80C
Pin Plunger 8 cylcles per hour/24 hours per day/365 days ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 No 1/2"NPT 4NC 2.5x10⁶ operations at 100mA load 356 Years -25C +80C
Pin Plunger 8 cylcles per hour/24 hours per day/365 days ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 No QC M23 4NC 2.5x10⁶ operations at 100mA load 356 Years -25C +80C
Pin Plunger 8 cylcles per hour/24 hours per day/365 days ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 No M20 1NC 1NO 2.5x10⁶ operations at 100mA load 356 Years -25C +80C
ISO 13849-1, ISO 14119, EN60204-1, EN62061, EN60947-5-1, UL 508 Yes 3m 4 core Ex 1NC 1NO -25C +80C
ISO 13849-1, ISO 14119, EN60204-1, EN62061, EN60947-5-1, UL 508 Yes 3m 8 core Ex 2NC 2NO -25C +80C
ISO 13849-1, ISO 14119, EN60204-1, EN62061, EN60947-5-1, UL 508 Yes 3m 4 core Ex 1NC 1NO -25C +80C
ISO 13849-1, ISO 14119, EN60204-1, EN62061, EN60947-5-1, UL 508 Yes 3m 8 core Ex 2NC 2NO -25C +80C
ISO 13849-1, ISO 14119, EN60204-1, EN62061, EN60947-5-1, UL 508 Yes 3m 4 core Ex 1NC 1NO -25C +80C
ISO 13849-1, ISO 14119, EN60204-1, EN62061, EN60947-5-1, UL 508 Yes 3m 8 core Ex 2NC 2NO -25C +80C

Part

174001
HLM SRL M20 '2NC 2NO'

Technical data

Actuator Short Roller Lever
Annual usage 8 cylcles per hour/24 hours per day/365 days
Approvals ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508
ATEX approved No
Conduit entry M20
Contacts 2NC 2NO
Housing material Die cast metal
IP class IP67
Mechanical reliability B10d 2.5x10⁶ operations at 100mA load
MTTFd 356 Years
Operating temperature -25C +80C
PFHd 3.44 x 10⁻⁸
Rated insulation voltage 300Vac
Thermal current (lth) 10 A

Measurements and connections

Contact us

If you need any help, you can contact us in one of the following ways:

0116 284 9900

Send an e-mail

Use live chat