IDEM
IDEM’s HLM range of heavy duty Die Cast Safety Limit Switches have been designed to be mounted for position sensing of moving applications e.g. guard doors, conveyors, machine beds and elevators. They are available with an extensive range of actuator heads and can be supplied with either slow break or snap action contacts.
Operation
Operation of IDEM Safety Limit Switches is achieved by a sliding actuation of the moving object to cause deflection of the switch plungers, rollers or levers.
For safety applications it is important that the moving object does not pass completely over the switch actuators so as to either cause damage to the actuator or allow it to return to its original position.
|
Parts | Price | Actuator | Annual usage | Approvals | ATEX approved | Conduit entry | Contacts | Mechanical reliability B10d | MTTFd | Operating temperature |
---|---|---|---|---|---|---|---|---|---|---|---|
|
![]()
174001
HLM SRL M20 '2NC 2NO'
|
|
Short Roller Lever | 8 cylcles per hour/24 hours per day/365 days | ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 | No | M20 | 2NC 2NO | 2.5x10⁶ operations at 100mA load | 356 Years | -25C +80C |
|
![]()
174001-GC
HLM SRL M20 '2NC 2NO' - GOLD Contacts
|
|
Short Roller Lever | 8 cylcles per hour/24 hours per day/365 days | ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 | No | M20 | 2NC 2NO | 2.5x10⁶ operations at 100mA load | 356 Years | -25C +80C |
|
![]()
174002
HLM SRL ½NPT '2NC 2NO'
|
|
Short Roller Lever | 8 cylcles per hour/24 hours per day/365 days | ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 | No | 1/2"NPT | 2NC 2NO | 2.5x10⁶ operations at 100mA load | 356 Years | -25C +80C |
|
![]()
174003
HLM SRL QC-M23 '2NC 2NO'
|
|
Short Roller Lever | 8 cylcles per hour/24 hours per day/365 days | ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 | No | QC M23 | 2NC 2NO | 2.5x10⁶ operations at 100mA load | 356 Years | -25C +80C |
|
![]()
174004
HLM SRL M20 '3NC 1NO'
|
|
Short Roller Lever | 8 cylcles per hour/24 hours per day/365 days | ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 | No | M20 | 3 NC 1 NO | 2.5x10⁶ operations at 100mA load | 356 Years | -25C +80C |
|
![]()
174004-GC
HLM SRL M20 '3NC 1NO' - with GOLD contacts
|
|
Short Roller Lever | 8 cylcles per hour/24 hours per day/365 days | ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 | No | M20 | 3 NC 1 NO | 2.5x10⁶ operations at 100mA load | 356 Years | -25C +80C |
|
![]()
174005
HLM SRL ½NPT '3NC 1NO'
|
|
Short Roller Lever | 8 cylcles per hour/24 hours per day/365 days | ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 | No | 1/2"NPT | 3 NC 1 NO | 2.5x10⁶ operations at 100mA load | 356 Years | -25C +80C |
|
![]()
174006
HLM SRL QC-M23 '3NC 1NO'
|
|
Short Roller Lever | 8 cylcles per hour/24 hours per day/365 days | ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 | No | QC M23 | 3 NC 1 NO | 2.5x10⁶ operations at 100mA load | 356 Years | -25C +80C |
|
![]()
174007
HLM SRL M20 '4NC'
|
|
Short Roller Lever | 8 cylcles per hour/24 hours per day/365 days | ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 | No | M20 | 4NC | 2.5x10⁶ operations at 100mA load | 356 Years | -25C +80C |
|
![]()
174008
HLM SRL ½NPT '4NC'
|
|
Short Roller Lever | 8 cylcles per hour/24 hours per day/365 days | ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 | No | 1/2"NPT | 4NC | 2.5x10⁶ operations at 100mA load | 356 Years | -25C +80C |
|
![]()
174009
HLM SRL QC-M23 4NC
|
|
Short Roller Lever | 8 cylcles per hour/24 hours per day/365 days | ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 | No | QC M23 | 4NC | 2.5x10⁶ operations at 100mA load | 356 Years | -25C +80C |
|
![]()
174010
HLM SRL M20 '1NC 1NO' Snap
|
|
Short Roller Lever | 8 cylcles per hour/24 hours per day/365 days | ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 | No | M20 | 1NC 1NO | 2.5x10⁶ operations at 100mA load | 356 Years | -25C +80C |
|
![]()
174011
HLM SRL ½NPT 1NC 1NO Snap
|
|
Short Roller Lever | 8 cylcles per hour/24 hours per day/365 days | ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 | No | 1/2"NPT | 1NC 1NO | 2.5x10⁶ operations at 100mA load | 356 Years | -25C +80C |
|
![]()
174012
HLM SRL QC-M23 '1NC 1NO' Snap
|
|
Short Roller Lever | 8 cylcles per hour/24 hours per day/365 days | ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 | No | QC M23 | 1NC 1NO | 2.5x10⁶ operations at 100mA load | 356 Years | -25C +80C |
|
![]()
174013
HLM SRL EX '1NC 1NO'
|
|
Short Roller Lever | 8 cylcles per hour/24 hours per day/365 days | ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 | Yes | 3m 4 core Ex | 1NC 1NO | 2.5x10⁶ operations at 100mA load | 356 Years | -25C +80C |
|
![]()
174014
HLM SRL EX '2NC'
|
|
Short Roller Lever | 8 cylcles per hour/24 hours per day/365 days | ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 | Yes | 3m 4 core Ex | 2NC | 2.5x10⁶ operations at 100mA load | 356 Years | -25C +80C |
|
![]()
174015
HLM SRL EX '2NC 2NO'
|
|
Short Roller Lever | 8 cylcles per hour/24 hours per day/365 days | ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 | Yes | 3m 8 core Ex | 2NC 2NO | 2.5x10⁶ operations at 100mA load | 356 Years | -25C +80C |
|
![]()
174051
HLM Roller Plunger M20 '2NC 2NO'
|
|
Roller Plunger | 8 cylcles per hour/24 hours per day/365 days | ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 | No | M20 | 2NC 2NO | 2.5x10⁶ operations at 100mA load | 356 Years | -25C +80C |
|
![]()
174051-GC
HLM Roller Plunger M20 '2NC 2NO' c/w Gold contacts
|
|
Roller Plunger | 8 cylcles per hour/24 hours per day/365 days | ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 | No | M20 | 2NC 2NO | 2.5x10⁶ operations at 100mA load | 356 Years | -25C +80C |
|
![]()
174052
HLM Roller Plunger ½NPT '2NC 2NO'
|
|
Roller Plunger | 8 cylcles per hour/24 hours per day/365 days | ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 | No | 1/2"NPT | 2NC 2NO | 2.5x10⁶ operations at 100mA load | 356 Years | -25C +80C |
|
![]()
174053
HLM Roller Plunger QC-M23 '2NC 2NO'
|
|
Roller Plunger | 8 cylcles per hour/24 hours per day/365 days | ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 | No | QC M23 | 2NC 2NO | 2.5x10⁶ operations at 100mA load | 356 Years | -25C +80C |
|
![]()
174054
HLM Roller Plunger M20 '3NC 1NO'
|
|
Roller Plunger | 8 cylcles per hour/24 hours per day/365 days | ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 | No | M20 | 3 NC 1 NO | 2.5x10⁶ operations at 100mA load | 356 Years | -25C +80C |
|
![]()
174055
HLM Roller Plunger ½NPT '3NC 1NO'
|
|
Roller Plunger | 8 cylcles per hour/24 hours per day/365 days | ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 | No | 1/2"NPT | 3 NC 1 NO | 2.5x10⁶ operations at 100mA load | 356 Years | -25C +80C |
|
![]()
174056
HLM Roller Plunger QC-M23 '3NC 1NO'
|
|
Roller Plunger | 8 cylcles per hour/24 hours per day/365 days | ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 | No | QC M23 | 3 NC 1 NO | 2.5x10⁶ operations at 100mA load | 356 Years | -25C +80C |
|
![]()
174057
HLM Roller Plunger M20 '4NC'
|
|
Roller Plunger | 8 cylcles per hour/24 hours per day/365 days | ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 | No | M20 | 4NC | 2.5x10⁶ operations at 100mA load | 356 Years | -25C +80C |
|
![]()
174058
HLM Roller Plunger ½NPT '4NC'
|
|
Roller Plunger | 8 cylcles per hour/24 hours per day/365 days | ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 | No | 1/2"NPT | 4NC | 2.5x10⁶ operations at 100mA load | 356 Years | -25C +80C |
|
![]()
174059
HLM Roller Plunger QC-M23 '4NC'
|
|
Roller Plunger | 8 cylcles per hour/24 hours per day/365 days | ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 | No | QC M23 | 4NC | 2.5x10⁶ operations at 100mA load | 356 Years | -25C +80C |
|
![]()
174060
HLM Roller Plunger M20 '1NC 1NO' Snap
|
|
Roller Plunger | 8 cylcles per hour/24 hours per day/365 days | ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 | No | M20 | 1NC 1NO | 2.5x10⁶ operations at 100mA load | 356 Years | -25C +80C |
|
![]()
174061
HLM Roller Plunger ½NPT '1NC 1NO' Snap
|
|
Roller Plunger | 8 cylcles per hour/24 hours per day/365 days | ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 | No | 1/2"NPT | 1NC 1NO | 2.5x10⁶ operations at 100mA load | 356 Years | -25C +80C |
|
![]()
174062
HLM Roller Plunger QC-M23 '1NC 1NO' Snap
|
|
Roller Plunger | 8 cylcles per hour/24 hours per day/365 days | ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 | No | QC M23 | 1NC 1NO | 2.5x10⁶ operations at 100mA load | 356 Years | -25C +80C |
|
![]()
174063
HLM Roller Plunger EX '1NC 1NO'
|
|
Roller Plunger | 8 cylcles per hour/24 hours per day/365 days | ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 | Yes | 3m 4 core Ex | 1NC 1NO | 2.5x10⁶ operations at 100mA load | 356 Years | -25C +80C |
|
![]()
174064
HLM Roller Plunger EX '2NC'
|
|
Roller Plunger | 8 cylcles per hour/24 hours per day/365 days | ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 | Yes | 3m 4 core Ex | 2NC | 2.5x10⁶ operations at 100mA load | 356 Years | -25C +80C |
|
![]()
174065
HLM Roller Plunger EX '2NC 2NO'
|
|
Roller Plunger | 8 cylcles per hour/24 hours per day/365 days | ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 | Yes | 3m 8 core Ex | 2NC 2NO | 2.5x10⁶ operations at 100mA load | 356 Years | -25C +80C |
|
![]()
174101
HLM Pin Plunger M20 '2NC 2NO'
|
|
Pin Plunger | 8 cylcles per hour/24 hours per day/365 days | ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 | No | M20 | 2NC 2NO | 2.5x10⁶ operations at 100mA load | 356 Years | -25C +80C |
|
![]()
174102
HLM Pin Plunger ½NPT '2NC 2NO'
|
|
Pin Plunger | 8 cylcles per hour/24 hours per day/365 days | ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 | No | 1/2"NPT | 2NC 2NO | 2.5x10⁶ operations at 100mA load | 356 Years | -25C +80C |
|
![]()
174103
HLM Pin Plunger QC-M23 '2NC 2NO'
|
|
Pin Plunger | 8 cylcles per hour/24 hours per day/365 days | ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 | No | QC M23 | 2NC 2NO | 2.5x10⁶ operations at 100mA load | 356 Years | -25C +80C |
|
![]()
174104
HLM Pin Plunger M20 '3NC 1NO'
|
|
Pin Plunger | 8 cylcles per hour/24 hours per day/365 days | ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 | No | M20 | 3 NC 1 NO | 2.5x10⁶ operations at 100mA load | 356 Years | -25C +80C |
|
![]()
174105
HLM Pin Plunger ½NPT '3NC 1NO'
|
|
Pin Plunger | 8 cylcles per hour/24 hours per day/365 days | ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 | No | 1/2"NPT | 3 NC 1 NO | 2.5x10⁶ operations at 100mA load | 356 Years | -25C +80C |
|
![]()
174106
HLM Pin Plunger QC-M23 '3NC 1NO'
|
|
Pin Plunger | 8 cylcles per hour/24 hours per day/365 days | ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 | No | QC M23 | 3 NC 1 NO | 2.5x10⁶ operations at 100mA load | 356 Years | -25C +80C |
|
![]()
174107
HLM Pin Plunger M20 '4NC'
|
|
Pin Plunger | 8 cylcles per hour/24 hours per day/365 days | ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 | No | M20 | 4NC | 2.5x10⁶ operations at 100mA load | 356 Years | -25C +80C |
|
![]()
174108
HLM Pin Plunger ½NPT '4NC'
|
|
Pin Plunger | 8 cylcles per hour/24 hours per day/365 days | ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 | No | 1/2"NPT | 4NC | 2.5x10⁶ operations at 100mA load | 356 Years | -25C +80C |
|
![]()
174109
HLM Pin Plunger QC-M23 '4NC'
|
|
Pin Plunger | 8 cylcles per hour/24 hours per day/365 days | ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 | No | QC M23 | 4NC | 2.5x10⁶ operations at 100mA load | 356 Years | -25C +80C |
|
![]()
174110
HLM Pin Plunger M20 '1NC 1NO' snap
|
|
Pin Plunger | 8 cylcles per hour/24 hours per day/365 days | ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 | No | M20 | 1NC 1NO | 2.5x10⁶ operations at 100mA load | 356 Years | -25C +80C |
|
![]()
174113
HLM Pin Plunger EX '1NC 1NO'
|
|
ISO 13849-1, ISO 14119, EN60204-1, EN62061, EN60947-5-1, UL 508 | Yes | 3m 4 core Ex | 1NC 1NO | -25C +80C | ||||
|
![]()
174115
HLM Pin Plunger EX '2NC 2NO'
|
|
ISO 13849-1, ISO 14119, EN60204-1, EN62061, EN60947-5-1, UL 508 | Yes | 3m 8 core Ex | 2NC 2NO | -25C +80C | ||||
|
![]()
174163
HLM Spring Lever EX '1NC 1NO'
|
|
ISO 13849-1, ISO 14119, EN60204-1, EN62061, EN60947-5-1, UL 508 | Yes | 3m 4 core Ex | 1NC 1NO | -25C +80C | ||||
|
![]()
174165
HLM Spring Lever EX '2NC 2NO'
|
|
ISO 13849-1, ISO 14119, EN60204-1, EN62061, EN60947-5-1, UL 508 | Yes | 3m 8 core Ex | 2NC 2NO | -25C +80C | ||||
|
![]()
174313
HLM Adj Roller Lever EX '1NC 1NO'
|
|
ISO 13849-1, ISO 14119, EN60204-1, EN62061, EN60947-5-1, UL 508 | Yes | 3m 4 core Ex | 1NC 1NO | -25C +80C | ||||
|
![]()
174315
HLM Adj Roller Lever EX '2NC 2NO'
|
|
ISO 13849-1, ISO 14119, EN60204-1, EN62061, EN60947-5-1, UL 508 | Yes | 3m 8 core Ex | 2NC 2NO | -25C +80C |
Actuator | Short Roller Lever |
---|---|
Annual usage | 8 cylcles per hour/24 hours per day/365 days |
Approvals | ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 |
ATEX approved | No |
Conduit entry | M20 |
Contacts | 2NC 2NO |
Housing material | Die cast metal |
IP class | IP67 |
Mechanical reliability B10d | 2.5x10⁶ operations at 100mA load |
MTTFd | 356 Years |
Operating temperature | -25C +80C |
PFHd | 3.44 x 10⁻⁸ |
Rated insulation voltage | 300Vac |
Thermal current (lth) | 10 A |
If you need any help, you can contact us in one of the following ways:
Cookies help us improve your experience with us, so in order to be able to handle login information, offer you personalised content and for basic functionality of this website, we use some cookies.
We will never sell on any information about you.
You can accept all cookies or personalise your cookies preferences, you can also change your cookie preferences at any time by visiting our contact page.