• black icon of a bullhorn 30 years industry experience
  • black icon of three cubes Over 8,000 products in stock
  • Black icon of a clock Order by 16:00 and receive the next working day
DATALOGIC
DATALOGIC

Datalogic - SG2-B 50/90

  • Range up to 19m
  • Protection height 150-1800 mm
  • Type 2 (PLc SIL 2)
  • Suitable for detection or personnel in a dangerous area

Product description

SG2-B 50/90 is suitable for detection of personnel in a dangerous area (Ie. horizontal detection of a person standing in a dangerous area) with a range of up to 19 metres.

 

This Type 2 light curtain maintains level PLc according to the latest safety standards, EN ISO 13849-1 and EN 62061.

 

SG2-B 50/90 has basic functionality with two OSSD (PNP) safety outputs and manual reset.

 

 

Part numbers

Parts Price Number of beams Protection height Reaction time Resolution
9 300 mm 9 ms 50 mm
7 450 mm 10 ms 50 mm
17 600 mm 11 ms 50 mm
21 750 mm 12 ms 50 mm
25 900 mm 14 ms 50 mm
29 1050 mm 15 ms 50 mm
33 1200 mm 16 ms 50 mm
37 1350 mm 17 ms 50 mm
41 1500 mm 18 ms 50 mm
45 1650 mm 19 ms 50 mm
49 1800 mm 20 ms 50 mm
5 300 mm 9 ms 90 mm
7 450 mm 10 ms 90 mm
9 600 mm 11 ms 90 mm
11 750 mm 12 ms 90 mm
13 900 mm 13 ms 90 mm
15 1050 mm 14 ms 90 mm
17 1200 mm 15 ms 90 mm
19 1350 mm 16 ms 90 mm
21 1500 mm 17 ms 90 mm
23 1650 mm 18 ms 90 mm
25 1800 mm 19 ms 90 mm

Part

SG2-50-030-OO-X
957801120 Type 2 50mm Res 300mm Protection Height

Technical data

Additional features Reset, test
Approvals CE, cULus, TÜV
Cable connection receiver M12, 5-pole
Cable connection transmitter M12, 4-pole
Cable length max 50 m
Contact current max 0,5 A
DC 97,50 %
In compliance with EMC, LVD, MD
IP class IP65
LED indication 6 x LED
Material of body Aluminium
MTTFd 273 year(s)
Number of beams 9
Output 2xPNP
PL c (EN ISO 13849-1)
Power consumption Transmitter 2W, receiver 3,5W (without load)
Protection height 300 mm
Range 0,2-19 m
Reaction time 9 ms
Resolution 50 mm
Safe outputs 2 x OSSD
SIL 1 (EN IEC 62061)
Supply voltage 24 V DC, stabilized
T1 (Life time in years) 20
Temperature operational max 55 °C
Temperature operational min -10 °C
Type 2
Voltage tolerance ±20 %

Resource

Contact us

If you need any help, you can contact us in one of the following ways:

0116 284 9900

Send an e-mail

Use live chat