DATASENSING

Datalogic - SG4-Body compact base

Datalogic safety light curtain SG4-BODY COMPACT Base is made for body detection with a range of up to 50 meters. The safety light curtain is available as type 4, and maintains highest level PL e according to the latest safety standards, EN ISO 13849-1 and EN 62061.

SG4-BODY COMPACT Base has a compact housing with basic functions as integrated manual reset /automatic reset and input for monitoring of external contactors (EDM). Configurations will be made by DIP switches.

 

SG4-BODY COMPACT models are provided in 2 different versions: Base and Muting.

 

SG4-BODY COMPACT Base safety light curtain include two safe electronic short-circuit detection outputs (PNP). If potential free contacts are needed We can offer forexample Datalogic safety relay CSME. Safety light curtain supplied complete with standard bracket.

 

Datalogic has a 3 year warranty for safety light curtains.

Read more
  • Body protection (2, 3 and 4 beam), Type 4, PL e
  • Range 0.5-50 m
  • Protective height 500-800-900-1200 mm

Selected variant

Selected variant

Technical data

Additional features EDM, reset functions
Approvals CE, cULus, TÃœV
Cable connection receiver M12, 8-pole
Cable connection transmitter M12, 5-pole
Cable length max 50 m
Contact current max 0,5 A
Distance max 50 m
Function EDM, Manual/automatic restart
In compliance with EMC, LVD, MD
IP class IP65
Material of body Aluminium
Number of beams 2
Output 2xPNP
PL e (EN ISO 13849-1)
Power consumption Transmitter 1,6W. Receiver 4,2 W. (without load)
Protection height 500 mm
Range 0,5-50 m
Safe outputs 2 OSSD
SFF 0.98929999999999996
SIL 3 (EN IEC 61508)
Supply voltage 24 V DC, stabilized
Supply voltage 24 V DC
Temperature operational max 55 °C
Temperature operational min -10 °C
Type 4
Voltage tolerance ±20 %

Product description

Datalogic safety light curtain SG4-BODY COMPACT Base is made for body detection with a range of up to 50 meters. The safety light curtain is available as type 4, and maintains highest level PL e according to the latest safety standards, EN ISO 13849-1 and EN 62061.

SG4-BODY COMPACT Base has a compact housing with basic functions as integrated manual reset /automatic reset and input for monitoring of external contactors (EDM). Configurations will be made by DIP switches.

 

SG4-BODY COMPACT models are provided in 2 different versions: Base and Muting.

 

SG4-BODY COMPACT Base safety light curtain include two safe electronic short-circuit detection outputs (PNP). If potential free contacts are needed We can offer forexample Datalogic safety relay CSME. Safety light curtain supplied complete with standard bracket.

 

Datalogic has a 3 year warranty for safety light curtains.

Accessories

Related products

Related

Parts Additional features Approvals Cable connection receiver Cable connection transmitter DC Disconnection Distance max Function In compliance with MTTFd Number of beams Output Power consumption Protection field Protection height Resolution SFF Storage temperature max Storage temperature min Supply voltage T1 (Life time in years) Price
CE, TÜV
M12, 4-pole
M12, 4-pole
98,90%
16 ms
Automatic restart
384 year(s)
4
Transmitter max 0,9 W. Receiver 2,2 W (without load)
900 mm
315 mm
99,38%
70 °C
-25 °C
20
CE, TÜV
M12, 4-pole
M12, 4-pole
98,90%
16 ms
Automatic restart
384 year(s)
4
Transmitter max 0,9 W. Receiver 2,2 W (without load)
1200 mm
415 mm
99,38%
70 °C
-25 °C
20
EDM, reset functions
CE, cULus, TÜV
M12, 8-pole
M12, 5-pole
50 m
EDM, Manual/automatic restart
EMC, LVD, MD
2
2xPNP
Transmitter 1,6W. Receiver 4,2 W. (without load)
500 mm
0.98929999999999996
24 V DC
EDM, reset functions
CE, cULus, TÜV
M12, 8-pole
M12, 5-pole
50 m
EDM, Manual/automatic restart
EMC, LVD, MD
3
2xPNP
Transmitter 1,6W. Receiver 4,2 W. (without load)
800 mm
98,93 %
24 V DC
EDM, reset functions
CE, cULus, TÜV
M12, 8-pole
M12, 5-pole
50 m
EDM, Manual/automatic restart
EMC, LVD, MD
4
2xPNP
Transmitter 1,6W. Receiver 4,2 W. (without load)
900 mm
98,93 %
24 V DC
EDM, reset functions
CE, cULus, TÜV
M12, 8-pole
M12, 5-pole
50 m
EDM, Manual/automatic restart
EMC, LVD, MD
4
Transmitter 1,6W. Receiver 4,2 W. (without load)
1200 mm
98,93 %
24 V DC

Selected variant

Select a variant in the list

Contact us

If you need any help, you can contact us in one of the following ways:

phone 0116 284 9900

Send an e-mail Send an e-mail

comments Use live chat