• black icon of a bullhorn 30 years industry experience
  • black icon of three cubes Over 8,000 products in stock
  • Black icon of a clock Order by 16:00 and receive the next working day
GELBAU
GELBAU

Gelbau - Control unit 452.4/462.4

  • 2 NO+1 CO output
  • Safety category 3 in accordance with EN954-1
  • Automatic or manual reset
  • Available with variable supply voltage

Product description

Compact control unit with only 22.5 mm enclosure for the monitoring of sensing strips in dangerous applications. It is also suitable for use on motorised gates which, in line with the standard, must have relays conforming to safety category 3. A low current is transmitted from the control unit connectors (Z1 and Z2) through the sensing strip, and a closed circuit is formed via a resistor (8.2 kΩ). The control units outputs cut the power if anyone/anything presses the sensing strip and also following a short-circuit or open circuit.

Technical data

Supply voltage

24 V AC/DC, 230 V AC

Tolerance

-15 % to +10 %

Consumption (operation)

3 W

Relay outputs:

Safe

2 NO (single)

Signal

1 CO

Max. contact voltage

250 V AC/24 V DC

Max. contact current

4 A AC/2 A DC

Fuse outputs

4 A

Disconnection time

15 ms

Max. length of sensing strip

100 m

Max. cable length to the sensing strip

50 m (min. 0.5 m²)

Status indication

4xLED

Ingress protection class:

Terminal block

IP20

Enclosure

IP40

Ambient temperature

-20 °C to +55 °C

Installation

DIN rail

Mechanical service life

3x107

Safety category

3 in accordance with EN954-1

Standard

EN1760-2, ZH1/494

Conforming to

MD, LVD, EMC

Approvals

Ce-marking, TÜV



Technical characteristics

Depending on safety requirements

 

• Force guided contacts

 

• Internal/external redundancy

 

 

 

User benefits

Status indication

• Safety category 3 in accordance with EN954-1

 

• 2 NO and 1 CO output

Red colormark

Strip activated

• Contact load 4 A

Yellow colormark

Fault in the safety circuit

• LED status indication

Green colormark

Output activated

• Monitoring of external contactors

Green colormark

Output activated

 

Dimensions

(mm)

Size, control unit B412.0

 

Connection

452.4 (One input)

462.4 (Two inputs)

452.4

462.4

1. One sensing strip.
Manual reset.
Monitoring of external contactors.

4. Two sensing strips.
Manual reset.
Monitoring of external contactors.

 

 

452.4

462.4

2. One sensing strip.
Automatic reset.
Monitoring of external contactors.

5. Two sensing strips.
Automatic reset.
Monitoring of external contactors.

 

 

452.4

462.4

3. Two sensing strips.
Automatic reset.
Monitoring of external contactors.

6. Several sensing strips.
Automatic reset.
Monitoring of external contactors.

 

Order number

Order no.

Description

3004.5246

Control unit 452.4, 2 NO+1 CO, one input, cat. 3, 24 V DC, 22.5 mm

3004.5240

Control unit 452.4, 2 NO+1 CO, one input, cat. 3, 230 V AC, 22.5 mm

3004.6246

Control unit 462.4, 2 NO+1 CO, 2 inputs, cat. 3, 24 V DC, 22.5 mm

3004.6240

Control unit 452.4, 2 NO+1 CO, 2 inputs, cat. 3, 230 V AC, 22.5 mm

3004.5242

Control unit 452.4, 2 NO+1 CO, 1 input, variable voltage

3004.6242

Control unit 462.4, 2 NO+1 CO, 2 inputs, variable voltage

 

Part numbers

Parts Price Supply voltage
24 V DC
230 V AC
24 V DC
230 V AC

Part

Photo of 45246

3004.5246
Resistance Evaluator Cat3. 1 Input,2x NO,1x CO Cont. 24Vdc

Technical data

Approvals CE, TÜV NORD
Cable length to clip list max 50 m (min. 0,5 m2)
Contact current max 4 A AC/DC
Contact voltage max 250 V AC/24 V DC
Disconnection 15 ms
Fuse output 4 A
In compliance with EMC, LVD, MD
IP class connection IP20
IP class of housing IP40
Mounting DIN rail
PL e enl. SS-EN ISO 13849-1:2008
Power consumption 3 W
Supply voltage 24 V DC
Temperature ambient from -20 °C
Temperature ambient to 55 °C
Terminal strip length max 100 m
Tolerance max 10 %
Tolerance min -15 %