IDEM HLM-CBA/HLM-SS-CBA Tape convergence sensor explosion proof

  • Explosion proof
  • 2 types of lever rollers
  • Perfect for smaller conveyors
  • Small dimensions
  • Different contact configurations

Product description

The offer of tape cone detectors in the Mini IDEM version complements a wide range of cable switches used for emergency stop along conveyors. They are mounted along the conveyor belt and indicate the crookedness of the conveyor belt. We offer standard models (casting made of metal) and made of stainless steel. The rollers of these breakers can be of plastic or stainless steel.

Part numbers

Parts Price Actuator Conduit entry Contacts Housing material IP class Number of poles Weight
Plastic Roller 3m 4 core Ex 1NC 1NO Die cast metal IP67
Plastic Roller 3m 4 core Ex 2NC Die cast metal IP67
Plastic Roller 3m 8 core Ex 2NC 2NO Die cast metal IP67 8 700 g
Stainless Steel Roller 3m 4 core Ex 1NC 1NO Die cast metal IP67
Stainless Steel Roller 3m 4 core Ex 2NC Die cast metal IP67
Stainless Steel Roller 3m 8 core Ex 2NC 2NO Die cast metal IP67 8
Plastic roller 3m 4 core Ex 1NC 1NO Stainless steel 316 IP69K
Plastic roller 3m 4 core Ex 2NC Stainless steel 316 IP69K
Plastic roller 3m 8 core Ex 2NC 2NO Stainless steel 316 IP69K
Stainless steel roller 3m 4 core Ex 1NC 1NO Stainless steel 316 IP69K
Stainless steel roller 3m 4 core Ex 2NC Stainless steel 316 IP69K
Stainless steel roller 3m 8 core Ex 2NC 2NO Stainless steel 316 IP69K 8 920 g

Part

IDEM HLM-CBA tape convergence sensor

174413
HLM-CBA-EX switch c/w Plastic Roller 1NC 1NO

Technical data

Actuator Plastic Roller
Approvals ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508
ATEX approved Yes
Cable length 3 m
Conduit entry 3m 4 core Ex
Contacts 1NC 1NO
Electrical lifetime 100,000 cycle min. (at full load)
Housing material Die cast metal
Integrated LED indication No
IP class IP67
Mechanical reliability B10d 500,000 operations at 100mA load
Minimum current 5V 5mA DC
Mounting 4 x M5
Operating temperature -20°C...+60°C
Rated insulation voltage 300 V AC
Thermal current (lth) 10 A
Utilisation category AC15
Vibration IEC68-2-6 10-55Hz 0.35mm
Withstand voltage 2500 V AC