SENSECA

VALCO LCD Level Sensor

The principle operation of the LCD-S level switch is based on the moderate shutdown of a series of resistors and reed contacts. These are placed inside the guiding rod by a magnetic float. The only moving parts will be the float which moves along the measuring rod. You can program the sensor manually or via the “MYVALCO” app using NFC technology, available on Android® app store.

General specifications for continuous level sensor with display. Other specifications are selectable in the part number builder form below.

 

General specifications for LCD level sensor:

  • Local indicator 4 digit (9999)
  • Display and electrical connection are independently rotable 335°/343°
  • Analogue output switchable mA or V
  • Configured via NFC communication system through the APP
  • Integrated data logger + export file data .csv
  • Up to 6m length
  • Maximum working pressure 50 bar
  • Operating ambient temperature -30°C ... +55°C
  • Standard working temperature up to 105°C
  • Minimum degree of protection IP65

 

When requesting a quote or speaking to a member of our team please specify the meauring length and total length you would like as this is customisable, the data below is based on a total length of 500mm and measuring length of 450mm.

Need Help? Email our Pressure & Flow team or call us for more information 0116 284 9900.

Read more
  • Local indicator 4 digit (9999)
  • Integrated data logger + export file data .csv
  • Up to 6m length
  • Analogue output switchable mA or V
  • Configured via NFC communication system through "MYVALCO" APP

Selected variant

Available in several variants

Selected variant

Technical data

IP class IP65
Length overall 500 mm
Material of connection AISI 316
Material of float Stainless steel 316
Measuring length 450 mm
Measuring resolution 5
Pressure max 30 bar
Process connection 1" UNI 228/1
Specific gravity 0.75
Temperature operational max 105 °C

Product description

The principle operation of the LCD-S level switch is based on the moderate shutdown of a series of resistors and reed contacts. These are placed inside the guiding rod by a magnetic float. The only moving parts will be the float which moves along the measuring rod. You can program the sensor manually or via the “MYVALCO” app using NFC technology, available on Android® app store.

General specifications for continuous level sensor with display. Other specifications are selectable in the part number builder form below.

 

General specifications for LCD level sensor:

  • Local indicator 4 digit (9999)
  • Display and electrical connection are independently rotable 335°/343°
  • Analogue output switchable mA or V
  • Configured via NFC communication system through the APP
  • Integrated data logger + export file data .csv
  • Up to 6m length
  • Maximum working pressure 50 bar
  • Operating ambient temperature -30°C ... +55°C
  • Standard working temperature up to 105°C
  • Minimum degree of protection IP65

 

When requesting a quote or speaking to a member of our team please specify the meauring length and total length you would like as this is customisable, the data below is based on a total length of 500mm and measuring length of 450mm.

Need Help? Email our Pressure & Flow team or call us for more information 0116 284 9900.

Accessories

Related

water treatment plant tank- water and wastewater - OEM Automatic Solutions
Learning hub

Water & Wastewater Solutions

OEM Automatics water and wastewater application specialists have gathered all our solutions in one place. Our products are used in everything from small municipal water works to larger regional plants.

Selection of pumps - understanding velocity and why it matters when choosing a pump
Learning hub

understanding viscosity - And Why It Matters When Choosing A Pump

Whether you’re pumping water, chocolate, oil or peanut butter knowing the product’s viscosity is essential to selecting the right pump. Find out more about viscosity and which pump may be suitable for your application!

Tecnoplastic float switch
Product news

Float switches built to perform and ready to ship

Whether you're looking to upgrade your current solution or secure a more robust float switch for your next project, Taurus delivers performance you can count on.

groups of pressure switches and sensors with reservoir background - pressure sensors or switches
Learning hub

How do I know if I need a pressure switch or a pressure sensor?

When choosing between a pressure switch and a pressure sensor, the key lies in understanding your application. Our Pressure Monitoring experts breaks down the two devices for you.

SAMOA pumps
Product news

We offer air diaphragm pumps by SAMOA

Pumps are now officially part of our product offering! As we build our pump portfolio, we’re proud to announce that we are an official distributor of SAMOA Industrial, a well-established name in the fluid handling industry.

Barcode scanner technology: choosing the right technology for your application
Learning hub

Barcode Scanner Technology: Choosing The Right Technology For Your Application

OEM Automatic's barcode scanner experts have broken down barcode technology to help you choose the right scanner for your application!

Parts Measuring resolution Pressure max Process connection Specific gravity Price
5
30 bar
1" UNI 228/1
0.75
5
30 bar
1 1/4" UNI 228/1
0.75
5
30 bar
1 1/4" UNI 7/1
0.75
5
30 bar
1 1/4 NPT
0.75
5
30 bar
1 1/2" UNI 228/1
0.75
5
30 bar
1 1/2" UNI 7/1
0.75
5
30 bar
1 1/2 NPT
0.75
5
30 bar
FSHX Flange
0.75
5
10 bar
1" UNI 228/1
0.55
5
10 bar
1 1/4" UNI 228/1
0.55
5
10 bar
1 1/4" UNI 7/1
0.55
5
10 bar
1 1/4 NPT
0.55
5
10 bar
1 1/2" UNI 228/1
0.55
5
10 bar
1 1/2" UNI 7/1
0.55
5
10 bar
1 1/2 NPT
0.55
5
10 bar
FSHX Flange
0.55
20
15 bar
1 1/2" UNI 228/1
0.78
20
15 bar
2" UNI 228/1
0.78
20
15 bar
2" UNI 7/1
0.78
20
15 bar
2" NPT
0.78
5
50 bar
2" UNI 228/1
0.7
5
50 bar
2" UNI 7/1
0.7
5
50 bar
2" NPT
0.7
5
50 bar
DN65 Flange
0.7
10-20
40 bar
2" UNI 228/1
0.65
10-20
40 bar
2" UNI 7/1
0.65
10-20
40 bar
2" NPT
0.65
10-20
40 bar
DN65 Flange
0.65
10-20
15 bar
DN125 Flange
0.6

Selected variant

Select a variant in the list

Contact us
If you need any help, you can contact us in one of the following ways:
0116 284 9900
Send e-mail
Use live chat
Do you need help?
Logo

Cookie settings for OEM.CO.UK

Cookies help us improve your experience with us, so in order to be able to handle login information, offer you personalised content and for basic functionality of this website, we use some cookies.

We will never sell on any information about you. 

You can accept all cookies or personalise your cookies preferences, you can also change your cookie preferences at any time by visiting our contact page.

Necessary Cookies

These cookies are necessary for the website to work and can not be turned off in our systems. They are usually used only in response to actions you have taken in connection with a service request, for example when setting personal preferences, logging in or filling out a form.

Analysis and measurement cookies

These cookies allow us to count the number of visits and traffic sources so that we can measure and improve our website performance. They help us know which pages are more or less popular and how visitors navigate around the site. The information that these cookies collect is aggregated and therefore completely anonymous. If you do not allow these cookies, we do not know when you have visited our website.

Marketing cookies

These cookies can be added by our partners. They can use them to create a profile of you, based on your interests, to show you more relevant information. They do not store any personal information - only information about your browser and device. If you do not accept these cookies, you will have a more general and less customized user experience.