ESI

ESI - PR3200 - Differential Pressure Sensor

The PR3200 differential pressure transmitter has two titanium alloy Silicon-on-Sapphire sensors, this offers a high performance with the true wet/wet operation. This is suitable for all liquids and gases compatible with stainless steel and titanium. Applications for this range include flow measurement for orifice plates and mass flow meters, plus static differential pressure measurement and control in combustion chambers.  They can also be used for condition monitoring and filter monitoring in high pressure hydraulic systems or for any other application on liquid or gas requiring dependable differential pressure measurement.

 

There are optional ATEX and IECEx approved versions of the PR3200 available for explosion protection for flammable gases (zone0), dusts (zone 20) and mining areas (group I M1).

 

Read more
  • Silicon-on-sapphire sensor technology
  • Wide range of pressure ranges from ultra-low to 200barDP
  • wet/wet OR dry/dry OPERATION
  • Durable designs for industrial and commercial installations

Selected variant

Available in several variants

Selected variant

Technical data

Ambient temperature -20..85°C
Approvals CE, IEC
Electrical connection DIN A 43650
EMC EN61000-6-4, EN61000-6-2
Linearity ≤±0.3% BSFL
Material of wetted parts Titanium alloy, Stainless steel AISI 304
Media temperature -20..85°C
Output 4-20 mA
Overpressure protection 0.75 bar
Pressure range max 0.5 bar
Pressure range min 0 bar
Pressure reference Differential
Process connection G1/4
Sensor technology Silicon-on-Sapphire
Storage temperature 5..40°C
Supply voltage 10-36 V DC

Measurements and connections

Product description

The PR3200 differential pressure transmitter has two titanium alloy Silicon-on-Sapphire sensors, this offers a high performance with the true wet/wet operation. This is suitable for all liquids and gases compatible with stainless steel and titanium. Applications for this range include flow measurement for orifice plates and mass flow meters, plus static differential pressure measurement and control in combustion chambers.  They can also be used for condition monitoring and filter monitoring in high pressure hydraulic systems or for any other application on liquid or gas requiring dependable differential pressure measurement.

 

There are optional ATEX and IECEx approved versions of the PR3200 available for explosion protection for flammable gases (zone0), dusts (zone 20) and mining areas (group I M1).

 

Accessories

Related

water treatment plant tank- water and wastewater - OEM Automatic Solutions
Learning hub

Water & Wastewater Solutions

OEM Automatics water and wastewater application specialists have gathered all our solutions in one place. Our products are used in everything from small municipal water works to larger regional plants.

groups of pressure switches and sensors with reservoir background - pressure sensors or switches
Learning hub

How do I know if I need a pressure switch or a pressure sensor?

When choosing between a pressure switch and a pressure sensor, the key lies in understanding your application. Our Pressure Monitoring experts breaks down the two devices for you.

suco pressure switches
Blog Learning hub

Select the pressure switch for you a step by step guide

When selecting a SUCO mechanical pressure switch, it's essential to consider several key factors...

Why hydrostatic level probes lie and how to stop it
Learning hub

Why hydrostatic level probes lie and how to stop it

In this article, our application experts explain why hydrostatic level probes appear to lie, the most common failures, and how OEM, working with Aplisens, can help engineers prevent them.

Aplisens what is hydrostatic level monitoring
Learning hub

What is hydrostatic level monitoring?

A hydrostatic level probe measures liquid level indirectly, by sensing pressure at a known depth. When the application is suitable and the installation is done properly, hydrostatic level probes offer several clear benefits.

Selection of pumps - understanding velocity and why it matters when choosing a pump
Learning hub

understanding viscosity - And Why It Matters When Choosing A Pump

Whether you’re pumping water, chocolate, oil or peanut butter knowing the product’s viscosity is essential to selecting the right pump. Find out more about viscosity and which pump may be suitable for your application!

Parts ATEX approved EX approvals Overpressure protection Pressure range max Price
0.75 bar
0.5 bar
1.5 bar
1 bar
15 bar
10 bar
75 bar
50 bar
150 bar
100 bar
300 bar
200 bar
Yes
Ex II 1 D Ex ia IIIC T135 °C Da, Ex II 1 G Ex ia IIC T4 Ga, Ex I M 1 Ex ia I Ma
0.75 bar
0.5 bar
Yes
Ex II 1 D Ex ia IIIC T135 °C Da, Ex II 1 G Ex ia IIC T4 Ga, Ex I M 1 Ex ia I Ma
1.5 bar
1 bar
Yes
Ex II 1 D Ex ia IIIC T135 °C Da, Ex II 1 G Ex ia IIC T4 Ga, Ex I M 1 Ex ia I Ma
15 bar
10 bar
Yes
Ex II 1 D Ex ia IIIC T135 °C Da, Ex II 1 G Ex ia IIC T4 Ga, Ex I M 1 Ex ia I Ma
75 bar
50 bar
Yes
Ex II 1 D Ex ia IIIC T135 °C Da, Ex II 1 G Ex ia IIC T4 Ga, Ex I M 1 Ex ia I Ma
150 bar
100 bar
Yes
Ex II 1 D Ex ia IIIC T135 °C Da, Ex II 1 G Ex ia IIC T4 Ga, Ex I M 1 Ex ia I Ma
300 bar
200 bar

Selected variant