APLISENS
The SGE-25 hydrostatic level probe measures liquid levels, based on a simple relationship between the height of the liquid column and the resulting hydrostatic pressure. The pressure measurement is carried out on the level of the separating diaphragm of the immersed probe and is related to atmospheric pressure through a capillary in the cable. The active sensing element is a piezoresistant silicon sensor separated from the medium by an isolating diaphragm. The electronic amplifier, which works in combination with the sensor, and is meant to standardize the signal, is additionally equipped with an overvoltage protection circuit, which protects the probe from damage caused by induced interference from atmospheric discharges or from associated heavy current engineering appliances.
Â
If there is a possibility of turbulence in the tank (for example, because of the mixer operating mixers or a turbulent inflow), the probe should be installed inside a screening tube (e.g. made of PVC). If the probe is to be lowered deeper than 100m, the cable should be hanged at steel lifting rope. Cleaning the probe diaphragm by mechanical means is strictly prohibited.
Â
Options include Exia, DNV approval, cable options, output options and Pt100 sensor.
Â
Applications include tanks, deep wells, waste water, oil/fuel etc
Cable length | 10 m |
---|---|
Deviation max | 0,6 % |
IP class | IP68 |
Manufacturer part no. | SGE-25//0-1mH20/4-20mA/PU/L=10 |
Material | Stainless steel |
Material cable | PUR |
Material of body | Stainless steel 316L |
Material of wetted parts | Hastelloy C, Stainless Steel SIS2350 (316L) |
Measurement technology | Pressure |
Mounting | Submersible |
---|---|
Pressure range max | 1 mH2O |
Pressure range min | 0 mH2O |
Signal type | 4-20 mA |
Supply voltage dc max | 36 V DC |
Supply voltage dc min | 8 V DC |
Temperature of media from | -25 °C |
Temperature of media to | 40 °C |
The SGE-25 hydrostatic level probe measures liquid levels, based on a simple relationship between the height of the liquid column and the resulting hydrostatic pressure. The pressure measurement is carried out on the level of the separating diaphragm of the immersed probe and is related to atmospheric pressure through a capillary in the cable. The active sensing element is a piezoresistant silicon sensor separated from the medium by an isolating diaphragm. The electronic amplifier, which works in combination with the sensor, and is meant to standardize the signal, is additionally equipped with an overvoltage protection circuit, which protects the probe from damage caused by induced interference from atmospheric discharges or from associated heavy current engineering appliances.
Â
If there is a possibility of turbulence in the tank (for example, because of the mixer operating mixers or a turbulent inflow), the probe should be installed inside a screening tube (e.g. made of PVC). If the probe is to be lowered deeper than 100m, the cable should be hanged at steel lifting rope. Cleaning the probe diaphragm by mechanical means is strictly prohibited.
Â
Options include Exia, DNV approval, cable options, output options and Pt100 sensor.
Â
Applications include tanks, deep wells, waste water, oil/fuel etc
OEM Automatics water and wastewater application specialists have gathered all our solutions in one place. Our products are used in everything from small municipal water works to larger regional plants.
Whether you’re pumping water, chocolate, oil or peanut butter knowing the product’s viscosity is essential to selecting the right pump. Find out more about viscosity and which pump may be suitable for your application!
Whether you're looking to upgrade your current solution or secure a more robust float switch for your next project, Taurus delivers performance you can count on.
When choosing between a pressure switch and a pressure sensor, the key lies in understanding your application. Our Pressure Monitoring experts breaks down the two devices for you.
Pumps are now officially part of our product offering! As we build our pump portfolio, we’re proud to announce that we are an official distributor of SAMOA Industrial, a well-established name in the fluid handling industry.
OEM Automatic's barcode scanner experts have broken down barcode technology to help you choose the right scanner for your application!
|
|
|
|
|
||
---|---|---|---|---|---|---|
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
Parts | Cable length | Deviation max | Manufacturer part no. | Pressure range max | Price | ||
---|---|---|---|---|---|---|---|
![]()
0..1mH2O, 4-20mA, 10m PU cable
Art:
SGE250001.000
Copied
|
10 m
|
0,6 %
|
SGE-25//0-1mH20/4-20mA/PU/L=10
|
1 mH2O
|
| ||
![]()
0..1mH2O, 4-20mA, 5m PU cable
Art:
SGE250001.001
Copied
|
5 m
|
0,6 %
|
SGE25/0-1mH2O/4-20mA/5m PUR
|
1 mH2O
|
| ||
![]()
0..2mH2O, 4-20mA, 10m PU cable
Art:
SGE250002.000
Copied
|
10 m
|
0,6 %
|
SGE-25//0-2[m]//PU/L=10
|
2 mH2O
|
| ||
![]()
0..2,5mH2O, 4-20mA, 10m PU cable
Art:
SGE2502.5.000
Copied
|
10 m
|
0,6 %
|
SGE25/0-2,5mH2O/4-20mA/10m PUR
|
2.5 mH2O
|
| ||
![]()
0..4mH2O, 4-20mA, 10m PU cable
Art:
SGE250004.000
Copied
|
10 m
|
0,3 %
|
SGE25/0-4mH2O/4-20mA/10m PUR
|
4 mH2O
|
| ||
![]()
0..6mH2O, 4-20mA, 10m PU cable
Art:
SGE250006.000
Copied
|
10 m
|
0,3 %
|
SGE25/0-6mH2O/4-20mA/10m PUR
|
6 mH2O
|
| ||
![]()
0..10mH2O, 4-20mA, 10m PU cable
Art:
SGE250010.000
Copied
|
10 m
|
0,2 %
|
SGE25/0-10mH2O/4-20mA/10m PUR
|
10 mH2O
|
| ||
![]()
0..10mH2O, 4-20mA, 20m PU cable
Art:
SGE250010.003
Copied
|
20 m
|
0,2 %
|
SGE25/0-10mH2O/4-20mA/20m PUR
|
10 mH2O
|
|
Select a variant in the list