CROUZET CONTROL
Chronos 2 series timer relays for DIN rail mounting with screw terminal connections and these versions have 2 x relay outputs with 8A rated changeover contacts in a 22.5mm wide housing.
Time range is adjustable (in sub ranges) from 0.1 sec to 100 hours using a selector switch and potentiometer on the front face of the device.
The most common supply voltage requirements are covered by the standard units but there are also special versions that offer additional supply voltage options if required.
Some units are single function and some are multi function with the required timing function set by a selector switch on the front face of the device. The available timing functions are defined by a set of letter codes that is common across the whole Crouzet range.
Approvals | CE, Lloyd´s, RoHS, UL |
---|---|
Breaking capacity | 2000 VA / 80W |
Cable area with sleeve | 2 x 1,5 mm² |
Cable area without sleeve | 2 x 2,5 mm² |
Close delay | 30 ms |
Electrical lifetime | 105 operations 8A 250V (resistive load) |
Function | A, Ac, At, B, Bw, C, D, Di, H, Ht |
IP class connection | IP20 |
IP class front | IP50 |
Mechanical life expectancy | 10 x 10⁶ operations |
Mounting | DIN rail |
Mounting | TS35 DIN Rail |
Multi-function | Yes |
Output | Relay 2 pole C/O |
---|---|
Power consumption | 0,6 W |
Relay output | 2 pole C/O |
Repeatability | 0,5 % |
Response time off | 120 ms |
Storage temperature max | 60 °C |
Storage temperature min | -30 °C |
Supply voltage | 12-240V AC/DC |
Switching current max | 8 A |
Temperature operational max | 60 °C |
Temperature operational min | -20 °C |
Time range | 0,1-1s, 1-10s, 6-60s, 1-10min, 6-60min, 1-10h, 10-100h |
Chronos 2 series timer relays for DIN rail mounting with screw terminal connections and these versions have 2 x relay outputs with 8A rated changeover contacts in a 22.5mm wide housing.
Time range is adjustable (in sub ranges) from 0.1 sec to 100 hours using a selector switch and potentiometer on the front face of the device.
The most common supply voltage requirements are covered by the standard units but there are also special versions that offer additional supply voltage options if required.
Some units are single function and some are multi function with the required timing function set by a selector switch on the front face of the device. The available timing functions are defined by a set of letter codes that is common across the whole Crouzet range.
This blog talks all things DC circuit protection including the key components: electronic circuit breakers, fuses and current monitoring devices. As well as how to choose the right protection.
Did you get a chance to visit IATECH at The Leicester Marriott Hotel? We had over 33 exhibitors and 8 fantastic Tech Talks throughout the day, Read all about the day, here.
To help experience the capabilities of Z+F machines first-hand, we provide an in-depth demonstration and workshop. These sessions will show the machines in action and allow you to understand their features and gain valuable insight into their operation and benefits.
We are thrilled to announce the launch of IATECH, THe Industrial Automation Technology expo at Leicester Marriott Hotel on 23rd October. The ultimate platform for showcasing our extensive product range and broad business areas, featuring over 50 leading suppliers under one roof!
The specialist vehicle industry can include automotive and EV, heavy vehicles such as agriculture and rail, and marine. This email takes you through some of the various products we offer for specialist vehicle applications.
This blog post delves into the key components, current trends, and best practices in power distribution, illustrating the significant impact these systems have on our daily operations and long-term energy strategies.
|
|
|
|
|
||
---|---|---|---|---|---|---|
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
Parts | Function | Multi-function | Output | Relay output | Supply voltage | Time range | Price | ||
---|---|---|---|---|---|---|---|---|---|
Timer RU2R3 Multifunction 2 x Relay 12-240V ac/dc
Art:
88866303
Copied
|
A, Ac, At, B, Bw, C, D, Di, H, Ht
|
Yes
|
Relay 2 pole C/O
|
2 pole C/O
|
12-240V AC/DC
|
0,1-1s, 1-10s, 6-60s, 1-10min, 6-60min, 1-10h, 10-100h
|
| ||
Timer RU2R1 Multifunction 2 x Relay 24V dc / 24-240V ac
Art:
88866305
Copied
|
A, Ac, At, B, Bw, C, D, Di, H, Ht
|
Yes
|
Relay 2 pole C/O
|
2 pole C/O
|
24V DC / 24-240V AC
|
0,1-1s, 1-10s, 6-60s, 1-10min, 6-60min, 1-10h, 10-100h
|
| ||
Timer RX2R1 Multifunction 2 x Relay 24V dc / 24-240V ac
Art:
88866385
Copied
|
Ad, Ah, N - Safe-guard, O, P, Pt, TL, Tt, W
|
Yes
|
Relay 2 pole C/O
|
2 pole C/O
|
24V DC / 24-240V AC
|
0,1-1s, 1-10s, 6-60s, 1-10min, 6-60min, 1-10h, 10-100h
|
| ||
Timer RA2R1 Delay Off 2 x Relay 24V dc / 24-240V ac
Art:
88866215
Copied
|
A, At
|
No
|
Relay 2 pole C/O
|
2 pole C/O
|
24V DC / 24-240V AC
|
0,1-1s, 1-10s, 6-60s, 1-10min, 6-60min, 1-10h, 10-100h
|
| ||
Timer TK2R1 True Delay Off 24V dc
Art:
88865265
Copied
|
K
|
No
|
Relay 2 pole C/O
|
2 pole C/O
|
24V DC / 24-240V AC
|
0,6-160 s
|
| ||
Timer RQR1 Star Delta 2 x Relay 24V dc / 24-240V ac
Art:
88866175
Copied
|
Q
|
No
|
Relay 1 pole C/O
|
1 pole C/O
|
24V DC / 24-240V AC
|
0,1-1s, 1-10s, 6-60s, 1-10min, 6-60min, 1-10h, 10-100h / 20-140ms
|
| ||
Timer RQR6 Star Delta 2 x Relay 230-240V ac / 380-440V ac
Art:
88866176
Copied
|
Q
|
No
|
Relay 1 pole C/O
|
1 pole C/O
|
230-240V AC / 380-440V AC
|
0,1-1s, 1-10s, 6-60s, 1-10min, 6-60min, 1-10h, 10-100h / 20-140ms
|
|