CONTA-CLIP
The DLI, DLIS range of installation terminals enable the ability to distribute power in a small footprint and gives the ability to disconnect the neutral connections.
Â
To comply to VDE 100 (IEC 364) and VDE 0108, which stipulates the requirement that a circuit's association must be clearly detectable.
Â
It is also required that an insulation test can be performed on each terminal without disconnecting the Neutral wire from the terminal blocks.
Â
This is a specific requirement for public buildings such as hospitals, schools, airports, office buildings and institutions.
Â
The terminals support the use of 10 x 3 busbar and is positioned on the outside of the terminals, the bar is held in place using the HP support plates. A sliding contact that contacts both sides of the busbar is used to connect and disconnect from the busbar.
Â
This sliding contact permits functional testing independent of the operational mode.
Â
Â
General data |
|
---|---|
Rated wire cross section | 2.5 mm² |
Colour | Beige |
Rated voltage IEC | 400 V |
Rated current IEC | 24 A |
Mounting | TS 35 |
Rated impulse voltage | 4 kV |
Overvoltage category | III |
Contamination degree | 3 |
Dimensions |
|
Length | 90.5 mm |
Width | 6 mm |
Height TS 35/7.5 | 53 mm |
Connection data |
|
Connections | 4 |
Special connections | Busbar 10 x 3mm |
Plug gauge acc. EN 60 947-1 | A3 |
Cross connect channels | 2 Â |
Cross section single wire from | 0.2 mm² |
Cross section single wire to | 4 mm² |
Cross section stranded wire from | 0.2 mm² |
Cross section stranded wire to | 4 mm² |
*Invisible Heading* |
|
---|---|
Cross section stranded with ferrule from | 0.2 mm² |
Cross section stranded with ferrule to | 2.5 mm² |
Rated wire cross section from (AWG) | 22 |
Rated wire cross section to (AWG) | 14 |
Stripping length | 8 mm |
Screw size | M 2,5 |
Screw type | Slotted |
Torque min | 0.4 |
Torque max | 0.8 |
Materials |
|
Insulation material | Polyamide 6.6 |
Flammability class | UL94-V2 |
Operating temperature from | -40 °C |
Operating temperature to | 105 °C |
Additional data |
|
Tariff code | 85369010 |
Country of origin | CZ |
Weight | 26.8 g |
Pack size | 50 Â |
Type of terminal | Screw Terminals, DIN Rail terminals |
The DLI, DLIS range of installation terminals enable the ability to distribute power in a small footprint and gives the ability to disconnect the neutral connections.
Â
To comply to VDE 100 (IEC 364) and VDE 0108, which stipulates the requirement that a circuit's association must be clearly detectable.
Â
It is also required that an insulation test can be performed on each terminal without disconnecting the Neutral wire from the terminal blocks.
Â
This is a specific requirement for public buildings such as hospitals, schools, airports, office buildings and institutions.
Â
The terminals support the use of 10 x 3 busbar and is positioned on the outside of the terminals, the bar is held in place using the HP support plates. A sliding contact that contacts both sides of the busbar is used to connect and disconnect from the busbar.
Â
This sliding contact permits functional testing independent of the operational mode.
Â
Â
This innovative push-in connection system enables time savings of up to 50%, whether you're wiring control panels or managing complex installations
Solar energy has become a pillar of the global energy transition. The experts at OEM Automatic have broken down the role of photovoltaic fuses and their contribution to solar systems, as well as, how to choose the right solution for you.
Ultra fast-acting fuse links engineered specifically to shield delicate semiconductor devices.
Do you need reliable protection for measuring and control equipment? DEHN YellowLine delivers voltage surge protection tailored for building, measuring, and control systems
Choosing the right circuit breaker is important for protecting DC circuits. Two primary forms of protection are MCBs and ECBs. The experts at OEM Automatic breakdown the two circuit breakers for you!
New signal lights from Auer Signal are now available! The first products to be launched in this series are the Smart Dot 50 in the Basic and Standard versions, as well as the Smart Indicator 50 in the Basic version.Â
|
|
|
|
|
||
---|---|---|---|---|---|---|
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
Parts | Rated wire cross section | Colour | Rated voltage IEC | Rated current IEC | Mounting | Rated impulse voltage | Overvoltage category | Contamination degree | Approvals | Additional information | Length | Width | Height TS 35/7.5 | Connections | Special connections | Plug gauge acc. EN 60 947-1 | Cross connect channels | Cross section single wire from | Cross section single wire to | Cross section stranded wire from | Cross section stranded wire to | Cross section stranded with ferrule from | Cross section stranded with ferrule to | Rated wire cross section from (AWG) | Rated wire cross section to (AWG) | Stripping length | Screw size | Screw type | Torque min | Torque max | Insulation material | Flammability class | Operating temperature from | Operating temperature to | CSA test standard | CSAus test standard | EAC test standard | KEMA KEUR test standard | Tariff code | Country of origin | Weight | Pack size | Type of terminal | Price | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]()
DLIS 2.5 PE/L/NT, 2.5mm² installation terminal, PE, live, neutral, busbar
Art:
1410.2
Copied
|
2.5 mm²
|
Beige
|
400 V
|
24 A
|
TS 35
|
4 kV
|
III
|
3
|
|
|
90.5 mm
|
6 mm
|
53 mm
|
4
|
Busbar 10 x 3mm
|
A3
|
2
|
0.2 mm²
|
4 mm²
|
0.2 mm²
|
4 mm²
|
0.2 mm²
|
2.5 mm²
|
22
|
14
|
8 mm
|
M 2,5
|
Slotted
|
0.4
|
0.8
|
Polyamide 6.6
|
UL94-V2
|
-40 °C
|
105 °C
|
|
|
|
|
85369010
|
CZ
|
26.8 g
|
50
|
Screw Terminals, DIN Rail terminals
|
| ||
![]()
DLIS 2.5 PE/L/N, 2.5mm² installation terminal, PE, live, neutral
Art:
1411.2
Copied
|
2.5 mm²
|
Beige
|
400 V
|
24 A
|
TS 35
|
4 kV
|
III
|
3
|
|
|
90.5 mm
|
6 mm
|
53 mm
|
5
|
|
A3
|
2
|
0.2 mm²
|
4 mm²
|
0.2 mm²
|
4 mm²
|
0.2 mm²
|
2.5 mm²
|
22
|
14
|
8 mm
|
M 2,5
|
Slotted
|
0.4
|
0.8
|
Polyamide 6.6
|
UL94-V2
|
-40 °C
|
105 °C
|
|
|
|
|
85369010
|
CZ
|
24.08 g
|
50
|
Screw Terminals, DIN Rail terminals
|
| ||
![]()
DLIS 2.5 PE/L/L, 2.5mm² installation terminal, PE, live, live
Art:
1412.2
Copied
|
2.5 mm²
|
Beige
|
400 V
|
24 A
|
TS 35
|
4 kV
|
III
|
3
|
|
|
90.5 mm
|
6 mm
|
53 mm
|
5
|
|
A3
|
2
|
0.2 mm²
|
4 mm²
|
0.2 mm²
|
4 mm²
|
0.2 mm²
|
2.5 mm²
|
22
|
14
|
8 mm
|
M 2,5
|
Slotted
|
0.4
|
0.8
|
Polyamide 6.6
|
UL94-V2
|
-40 °C
|
105 °C
|
|
|
|
|
85369010
|
CZ
|
24.08 g
|
50
|
Screw Terminals, DIN Rail terminals
|
| ||
![]()
DLIS 2.5 L/N, 2.5mm² installation terminal, live, neutral
Art:
1413.2
Copied
|
2.5 mm²
|
Beige
|
400 V
|
24 A
|
TS 35
|
4 kV
|
III
|
3
|
|
|
90.5 mm
|
6 mm
|
53 mm
|
4
|
|
A3
|
2
|
0.2 mm²
|
4 mm²
|
0.2 mm²
|
4 mm²
|
0.2 mm²
|
2.5 mm²
|
22
|
14
|
8 mm
|
M 2,5
|
Slotted
|
0.4
|
0.8
|
Polyamide 6.6
|
UL94-V2
|
-40 °C
|
105 °C
|
|
|
|
|
85369010
|
DE
|
14.04 g
|
50
|
Screw Terminals, DIN Rail terminals
|
| ||
![]()
DLIS 2.5 L/L, 2.5mm² installation terminal, live, live
Art:
1414.2
Copied
|
2.5 mm²
|
Beige
|
400 V
|
24 A
|
TS 35
|
4 kV
|
III
|
3
|
|
|
90.5 mm
|
6 mm
|
53 mm
|
4
|
|
A3
|
2
|
0.2 mm²
|
4 mm²
|
0.2 mm²
|
4 mm²
|
0.2 mm²
|
2.5 mm²
|
22
|
14
|
8 mm
|
M 2,5
|
Slotted
|
0.4
|
0.8
|
Polyamide 6.6
|
UL94-V2
|
-40 °C
|
105 °C
|
|
|
|
|
85369010
|
CZ
|
14.04 g
|
50
|
Screw Terminals, DIN Rail terminals
|
| ||
![]()
DLIS 2.5 N, 2.5mm² installation terminal, neutral
Art:
1415.2
Copied
|
2.5 mm²
|
Beige
|
400 V
|
24 A
|
TS 35
|
4 kV
|
III
|
3
|
|
|
90.5 mm
|
6 mm
|
53 mm
|
2
|
|
A3
|
1
|
0.2 mm²
|
4 mm²
|
0.2 mm²
|
4 mm²
|
0.2 mm²
|
2.5 mm²
|
22
|
14
|
8 mm
|
M 2,5
|
Slotted
|
0.4
|
0.8
|
Polyamide 6.6
|
UL94-V2
|
-40 °C
|
105 °C
|
|
|
|
|
85369010
|
DE
|
10.76 g
|
50
|
Screw Terminals, DIN Rail terminals
|
| ||
![]()
DLIS 2.5 L, 2.5mm² installation terminal, live
Art:
1416.2
Copied
|
2.5 mm²
|
Beige
|
400 V
|
24 A
|
TS 35
|
4 kV
|
III
|
3
|
|
|
90.5 mm
|
6 mm
|
53 mm
|
2
|
|
A3
|
1
|
0.2 mm²
|
4 mm²
|
0.2 mm²
|
4 mm²
|
0.2 mm²
|
2.5 mm²
|
22
|
14
|
8 mm
|
M 2,5
|
Slotted
|
0.4
|
0.8
|
Polyamide 6.6
|
UL94-V2
|
-40 °C
|
105 °C
|
|
|
|
|
85369010
|
DE
|
10.76 g
|
50
|
Screw Terminals, DIN Rail terminals
|
| ||
![]()
DLI 2,5 PE/L/NT, 2.5mm² installation terminal, PE, live, neutral, slide
Art:
1417.2
Copied
|
2.5 mm²
|
Beige
|
400 V
|
24 A
|
TS 35
|
4 kV
|
III
|
3
|
EAC
|
|
90.5 mm
|
6 mm
|
53 mm
|
5
|
|
A3
|
3
|
0.2 mm²
|
4 mm²
|
0.2 mm²
|
4 mm²
|
0.2 mm²
|
2.5 mm²
|
22
|
14
|
8 mm
|
M 2,5
|
Slotted
|
0.4
|
0.8
|
Polyamide 6.6
|
UL94-V2
|
-40 °C
|
105 °C
|
|
|
TR ZU 004/2011
|
|
85369010
|
DE
|
28.76 g
|
50
|
|
| ||
![]()
DLI 2,5 PE/L/N, 2.5mm² installation terminal, PE, live, neutral,
Art:
1418.2
Copied
|
2.5 mm²
|
Beige
|
400 V
|
24 A
|
TS 35
|
4 kV
|
III
|
3
|
CSA, CSA US, KEMA KUR, EAC
|
|
90.5 mm
|
6 mm
|
53 mm
|
5
|
|
A3
|
3
|
0.2 mm²
|
4 mm²
|
0.2 mm²
|
4 mm²
|
0.2 mm²
|
2.5 mm²
|
22
|
14
|
8 mm
|
M 2,5
|
Slotted
|
0.4
|
0.8
|
Polyamide 6.6
|
UL94-V2
|
-40 °C
|
105 °C
|
C22.2 No 158
|
UL 1059
|
TR ZU 004/2011
|
EN 60947-7-1:2009, EN 60947-7-2:2009
|
85369010
|
DE
|
26.08 g
|
50
|
|
| ||
![]()
DLI 2.5 PE/L/L, 2.5mm² installation terminal, PE, live, live
Art:
1419.2
Copied
|
2.5 mm²
|
Beige
|
400 V
|
24 A
|
TS 35
|
4 kV
|
III
|
3
|
CSA, CSA US, KEMA KUR, EAC
|
|
90.5 mm
|
6 mm
|
53 mm
|
5
|
|
A3
|
3
|
0.2 mm²
|
4 mm²
|
0.2 mm²
|
4 mm²
|
0.2 mm²
|
2.5 mm²
|
22
|
14
|
8 mm
|
M 2,5
|
Slotted
|
0.4
|
0.8
|
Polyamide 6.6
|
UL94-V2
|
-40 °C
|
105 °C
|
C22.2 No 158
|
UL 1059
|
TR ZU 004/2011
|
EN 60947-7-1:2009, EN 60947-7-2:2009
|
85369010
|
CZ
|
26.08 g
|
50
|
Screw Terminals, DIN Rail terminals
|
| ||
![]()
DLI 2,5 L/N, 2.5mm² installation terminal, live, neutral
Art:
1420.2
Copied
|
2.5 mm²
|
Beige
|
400 V
|
24 A
|
TS 35
|
4 kV
|
III
|
3
|
CSA, CSA US, KEMA KUR, EAC
|
|
90.5 mm
|
6 mm
|
53 mm
|
4
|
|
A3
|
3
|
0.2 mm²
|
4 mm²
|
0.2 mm²
|
4 mm²
|
0.2 mm²
|
2.5 mm²
|
22
|
14
|
8 mm
|
M 2,5
|
Slotted
|
0.4
|
0.8
|
Polyamide 6.6
|
UL94-V2
|
-40 °C
|
105 °C
|
C22.2 No 158
|
UL 1059
|
TR ZU 004/2011
|
EN 60947-7-1:2009
|
85369010
|
DE
|
16.08 g
|
50
|
|
| ||
![]()
DLI 2,5 L/L, 2.5mm² installation terminal, live, live
Art:
1421.2
Copied
|
2.5 mm²
|
Beige
|
400 V
|
24 A
|
TS 35
|
4 kV
|
III
|
3
|
CSA, CSA US, KEMA KUR, EAC
|
|
90.5 mm
|
6 mm
|
53 mm
|
4
|
|
A3
|
3
|
0.2 mm²
|
4 mm²
|
0.2 mm²
|
4 mm²
|
0.2 mm²
|
2.5 mm²
|
22
|
14
|
8 mm
|
M 2,5
|
Slotted
|
0.4
|
0.8
|
Polyamide 6.6
|
UL94-V2
|
-40 °C
|
105 °C
|
C22.2 No 158
|
UL 1059
|
TR ZU 004/2011
|
EN 60947-7-1:2009
|
85369010
|
DE
|
16.08 g
|
50
|
|
| ||
![]()
DLI 2,5 N, 2.5mm² installation terminal, neutral
Art:
1422.2
Copied
|
2.5 mm²
|
Beige
|
400 V
|
24 A
|
TS 35
|
4 kV
|
III
|
3
|
CSA, CSA US, EAC
|
|
90.5 mm
|
6 mm
|
53 mm
|
2
|
|
A3
|
2
|
0.2 mm²
|
4 mm²
|
0.2 mm²
|
4 mm²
|
0.2 mm²
|
2.5 mm²
|
22
|
14
|
8 mm
|
M 2,5
|
Slotted
|
0.4
|
0.8
|
Polyamide 6.6
|
UL94-V2
|
-40 °C
|
105 °C
|
C22.2 No 158
|
UL 1059
|
TR ZU 004/2011
|
|
85369010
|
DE
|
12.12 g
|
50
|
|
| ||
![]()
DLI 2,5 L, 2.5mm² installation terminal, live
Art:
1423.2
Copied
|
2.5 mm²
|
Beige
|
400 V
|
24 A
|
TS 35
|
4 kV
|
III
|
3
|
CSA, CSA US, EAC
|
|
90.5 mm
|
6 mm
|
53 mm
|
2
|
|
A3
|
2
|
0.2 mm²
|
4 mm²
|
0.2 mm²
|
4 mm²
|
0.2 mm²
|
2.5 mm²
|
22
|
14
|
8 mm
|
M 2,5
|
Slotted
|
0.4
|
0.8
|
Polyamide 6.6
|
UL94-V2
|
-40 °C
|
105 °C
|
C22.2 No 158
|
UL 1059
|
TR ZU 004/2011
|
|
85369010
|
DE
|
12.12 g
|
50
|
|
| ||
![]()
DLIS 2.5 B-W, 2.5mm² installation 3-phase terminal block
Art:
1446.2
Copied
|
2.5 mm²
|
Beige
|
400 V
|
24 A
|
TS 35
|
4 kV
|
III
|
3
|
|
block for AC application
|
90.5 mm
|
18 mm
|
53 mm
|
12
|
Busbar 10 x 3mm
|
A3
|
|
0.2 mm²
|
4 mm²
|
0.2 mm²
|
4 mm²
|
0.2 mm²
|
2.5 mm²
|
22
|
14
|
8 mm
|
M 2,5
|
Slotted
|
0.4
|
0.8
|
Polyamide 6.6
|
UL94-V2
|
-40 °C
|
105 °C
|
|
|
|
|
85369010
|
DE
|
80.43 g
|
16
|
Screw Terminals, DIN Rail terminals
|
| ||
![]()
DLIS 2.5 B-D, 2.5mm² installation 3-phase terminal block
Art:
1447.2
Copied
|
2.5 mm²
|
Beige
|
400 V
|
24 A
|
TS 35
|
4 kV
|
III
|
3
|
|
block for 3-phase application
|
90.5 mm
|
12 mm
|
53 mm
|
8
|
Busbar 10 x 3mm
|
A3
|
|
0.2 mm²
|
4 mm²
|
0.2 mm²
|
4 mm²
|
0.2 mm²
|
2.5 mm²
|
22
|
14
|
8 mm
|
M 2,5
|
Slotted
|
0.4
|
0.8
|
Polyamide 6.6
|
UL94-V2
|
-40 °C
|
105 °C
|
|
|
|
|
85369010
|
DE
|
41.44 g
|
25
|
Screw Terminals, DIN Rail terminals
|
| ||
![]()
DLI 2,5 B-W, 2.5mm² installation terminal block, slide
Art:
1448.2
Copied
|
2.5 mm²
|
Beige
|
400 V
|
24 A
|
TS 35
|
4 kV
|
III
|
3
|
EAC
|
block for AC application
|
90.5 mm
|
18 mm
|
53 mm
|
15
|
|
A3
|
3
|
0.2 mm²
|
4 mm²
|
0.2 mm²
|
4 mm²
|
0.2 mm²
|
2.5 mm²
|
22
|
14
|
8 mm
|
M 2,5
|
Slotted
|
0.4
|
0.8
|
Polyamide 6.6
|
UL94-V2
|
-40 °C
|
105 °C
|
|
|
TR ZU 004/2011
|
|
85369010
|
DE
|
86.25 g
|
16
|
|
| ||
![]()
DLI 2,5 B-D, 2.5mm² installation 3-phase terminal block, slide
Art:
1449.2
Copied
|
2.5 mm²
|
Beige
|
400 V
|
24 A
|
TS 35
|
4 kV
|
III
|
3
|
EAC
|
block for 3-phase application
|
90.5 mm
|
12 mm
|
53 mm
|
9
|
|
A3
|
|
0.2 mm²
|
4 mm²
|
0.2 mm²
|
4 mm²
|
0.2 mm²
|
2.5 mm²
|
22
|
14
|
8 mm
|
M 2,5
|
Slotted
|
0.4
|
0.8
|
Polyamide 6.6
|
UL94-V2
|
-40 °C
|
105 °C
|
|
|
TR ZU 004/2011
|
|
85369010
|
DE
|
44.63 g
|
25
|
|
| ||
![]()
DLI 2,5 D, 2.5mm² installation terminal, live
Art:
1490.2
Copied
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
![]()
DLIS 2.5 B-3L/3N/3PE, 2.5mm² installation terminal block, 3 x PE, 3 x live, 3 x neutral
Art:
2715.2
Copied
|
2.5 mm²
|
Beige
|
400 V
|
24 A
|
TS 35
|
4 kV
|
III
|
3
|
|
block for AC application
|
90.5 mm
|
18 mm
|
53 mm
|
15
|
|
A3
|
2
|
0.2 mm²
|
4 mm²
|
0.2 mm²
|
4 mm²
|
0.2 mm²
|
2.5 mm²
|
22
|
14
|
8 mm
|
M 2,5
|
Slotted
|
0.4
|
0.8
|
Polyamide 6.6
|
UL94-V2
|
-40 °C
|
105 °C
|
|
|
|
|
85369010
|
DE
|
69.27 g
|
16
|
Screw Terminals, DIN Rail terminals
|
| ||
![]()
DLIS 2.5 B-3L/N/PE, 2.5mm² installation terminal block, PE, 3 x live, neutral
Art:
2716.2
Copied
|
2.5 mm²
|
Beige
|
400 V
|
24 A
|
TS 35
|
4 kV
|
III
|
3
|
|
block for 3-phase application
|
90.5 mm
|
18 mm
|
53 mm
|
9
|
|
A3
|
2
|
0.2 mm²
|
4 mm²
|
0.2 mm²
|
4 mm²
|
0.2 mm²
|
2.5 mm²
|
22
|
14
|
8 mm
|
M 2,5
|
Slotted
|
0.4
|
0.8
|
Polyamide 6.6
|
UL94-V2
|
-40 °C
|
105 °C
|
|
|
|
|
85369010
|
DE
|
48.04 g
|
25
|
Screw Terminals, DIN Rail terminals
|
| ||
![]()
DLIS 2.5 B-6L, 2.5mm² installation terminal block, 6 x live
Art:
2717.2
Copied
|
2.5 mm²
|
Beige
|
400 V
|
24 A
|
TS 35
|
4 kV
|
III
|
3
|
|
|
90.5 mm
|
18 mm
|
53 mm
|
12
|
|
A3
|
2
|
0.2 mm²
|
4 mm²
|
0.2 mm²
|
4 mm²
|
0.2 mm²
|
2.5 mm²
|
22
|
14
|
8 mm
|
M 2,5
|
Slotted
|
0.4
|
0.8
|
Polyamide 6.6
|
UL94-V2
|
-40 °C
|
105 °C
|
|
|
|
|
85369010
|
DE
|
42.23 g
|
16
|
Screw Terminals, DIN Rail terminals
|
| ||
![]()
DLIS 2.5 B-6L/3PE, 2.5mm² installation terminal block, 3 x PE, 3 x live
Art:
2718.2
Copied
|
2.5 mm²
|
Beige
|
400 V
|
24 A
|
TS 35
|
4 kV
|
III
|
3
|
|
|
90.5 mm
|
18 mm
|
53 mm
|
15
|
|
A3
|
2
|
0.2 mm²
|
4 mm²
|
0.2 mm²
|
4 mm²
|
0.2 mm²
|
2.5 mm²
|
22
|
14
|
8 mm
|
M 2,5
|
Slotted
|
0.4
|
0.8
|
Polyamide 6.6
|
UL94-V2
|
-40 °C
|
105 °C
|
|
|
|
|
85369010
|
DE
|
72.23 g
|
16
|
Screw Terminals, DIN Rail terminals
|
|
Select a variant in the list