CONTA-CLIP
With a width of just 5 and 6 mm, the PRKD series of Push In Double level terminlas are available in various versions for cross- sections 2.5 mm² and 4 mm² cable sizes
The Push-in spring opens automatically when the wire is inserted giving a secure contact with the busbar. The integrated insulated orange pusher can be used to open the clamp to release the wire or to insert stranded wire without ferrules.
Linked SV versions and colour coded options offers a flexible and compact connection system where space is at a premium.
General data |
|
|---|---|
| Rated wire cross section | 2.5 mm² |
| Colour | Grey |
| Rated voltage IEC | 500 V |
| Rated current IEC | 22 A |
| Mounting | Mounting rail TS 35/7.5 |
| Rated impulse voltage | 6 kV |
| Overvoltage category | III |
| Contamination degree | 3 |
Dimensions |
|
| Length | 68.7 mm |
| Width | 5.1 mm |
| Height TS 35/7.5 | 47.2 mm |
| Height | 45.7 mm |
Connection data |
|
| Connections | 2 x 2 |
| Number of levels | 2 |
| Plug gauge acc. EN 60 947-1 | A3 |
| Cross connect channels | 2 |
| Cross section single wire from | 0.14 mm² |
| Cross section single wire to | 4 mm² |
*Invisible Heading* |
|
|---|---|
| Cross section stranded wire from | 0.14 mm² |
| Cross section stranded wire to | 2.5 mm² |
| Cross section stranded with ferrule from | 0.14 mm² |
| Cross section stranded with ferrule to | 2.5 mm² |
| Rated wire cross section from | 26 AWG |
| Rated wire cross section to | 12 AWG |
| Stripping length | 10 mm |
Materials |
|
| Insulation material | Polyamide 6.6 |
| Flammability class | UL94-V0 |
| Operating temperature from | -40 °C |
| Operating temperature to | 120 °C |
Additional data |
|
| Tariff code | 85369010 |
| Country of origin | CZ |
| Weight | 10.31 g |
| Pack size | 50 |
| Number of terminals per level | 2 |
With a width of just 5 and 6 mm, the PRKD series of Push In Double level terminlas are available in various versions for cross- sections 2.5 mm² and 4 mm² cable sizes
The Push-in spring opens automatically when the wire is inserted giving a secure contact with the busbar. The integrated insulated orange pusher can be used to open the clamp to release the wire or to insert stranded wire without ferrules.
Linked SV versions and colour coded options offers a flexible and compact connection system where space is at a premium.
You already added this product. Choose whether to increase quantity on the existing row or add the product as a new row.
Robotics has revolutionised industry, enabling efficiency, higher production capacity and increased safety. For a robot solution to function optimally, the right components are required.
Discover why colour brilliance matters in industrial signalling. Improve safety, reduce misinterpretation and ensure clear machine status in any environment.
Have you ever wondered if there's any difference between cable coils and cable reels?
Our cable experts take you through the advantages of using cable coils.
What tri-rated cable are you currently using? Does the product or service you receive leave you wanting more? It’s time to ask the question. Because now, you’ve got options.
This innovative push-in connection system enables time savings of up to 50%, whether you're wiring control panels or managing complex installations
Solar energy has become a pillar of the global energy transition. The experts at OEM Automatic have broken down the role of photovoltaic fuses and their contribution to solar systems, as well as, how to choose the right solution for you.
|
|
|
|
|
|
||
|---|---|---|---|---|---|---|
|
|
|
|
|
|
||
|
|
|
|
|
|
||
|
|
|
|
|
|
||
|
|
|
|
|
|
||
|
|
|
|
|
|
||
|
|
|
|
|
|
| Parts | Rated wire cross section | Colour | Rated voltage IEC | Rated current IEC | Overvoltage category | Additional information | Length | Width | Height TS 35/7.5 | Height | Connections | Plug gauge acc. EN 60 947-1 | Cross section single wire from | Cross section single wire to | Cross section stranded wire from | Cross section stranded wire to | Cross section stranded with ferrule from | Cross section stranded with ferrule to | Rated wire cross section from | Rated wire cross section to | Stripping length | Flammability class | Country of origin | Weight | Number of terminals per level | Price | ||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
PRKD 2.5 Grey, 2.5mm² double deck terminal
Art:
27036.6
Copied
|
2.5 mm²
|
Grey
|
500 V
|
22 A
|
III
|
|
68.7 mm
|
5.1 mm
|
47.2 mm
|
45.7 mm
|
2 x 2
|
A3
|
0.14 mm²
|
4 mm²
|
0.14 mm²
|
2.5 mm²
|
0.14 mm²
|
2.5 mm²
|
26 AWG
|
12 AWG
|
10 mm
|
UL94-V0
|
CZ
|
10.31 g
|
2
|
|
||
|
PRKD 2.5/SV Blue, 2.5mm² linked double deck terminal
Art:
27038.5
Copied
|
2.5 mm²
|
Blue
|
500 V
|
22 A
|
III
|
connected vertically
|
68.7 mm
|
5.1 mm
|
47.2 mm
|
45.7 mm
|
4
|
A3
|
0.14 mm²
|
4 mm²
|
0.14 mm²
|
2.5 mm²
|
0.14 mm²
|
2.5 mm²
|
26 AWG
|
12 AWG
|
10 mm
|
UL94-V0
|
CZ
|
10.53 g
|
2
|
|
||
|
PRKD 2.5/SV Orange, 2.5mm² linked double deck terminal
Art:
27038.3
Copied
|
2.5 mm²
|
Orange
|
500 V
|
22 A
|
III
|
connected vertically
|
68.7 mm
|
5.1 mm
|
47.2 mm
|
45.7 mm
|
4
|
A3
|
0.14 mm²
|
4 mm²
|
0.14 mm²
|
2.5 mm²
|
0.14 mm²
|
2.5 mm²
|
26 AWG
|
12 AWG
|
10 mm
|
UL94-V0
|
CZ
|
10.53 g
|
2
|
|
||
|
PRKD 2.5 Blue, 2.5mm² double deck terminal
Art:
27036.5
Copied
|
2.5 mm²
|
Blue
|
500 V
|
22 A
|
III
|
|
68.7 mm
|
5.1 mm
|
47.2 mm
|
45.7 mm
|
2 x 2
|
A3
|
0.14 mm²
|
4 mm²
|
0.14 mm²
|
2.5 mm²
|
0.14 mm²
|
2.5 mm²
|
26 AWG
|
12 AWG
|
10 mm
|
UL94-V0
|
CZ
|
10.31 g
|
2
|
|
||
|
PRKD 2.5/SV Grey, 2.5mm² linked double deck terminal
Art:
27038.6
Copied
|
2.5 mm²
|
Grey
|
500 V
|
22 A
|
III
|
connected vertically
|
68.7 mm
|
5.1 mm
|
47.2 mm
|
45.7 mm
|
4
|
A3
|
0.14 mm²
|
4 mm²
|
0.14 mm²
|
2.5 mm²
|
0.14 mm²
|
2.5 mm²
|
26 AWG
|
12 AWG
|
10 mm
|
UL94-V0
|
CZ
|
10.53 g
|
2
|
|
||
|
PRKD 2.5 Orange, 2.5mm² double deck terminal
Art:
27036.3
Copied
|
2.5 mm²
|
Orange
|
500 V
|
22 A
|
III
|
|
68.7 mm
|
5.1 mm
|
47.2 mm
|
45.7 mm
|
2 x 2
|
A3
|
0.14 mm²
|
4 mm²
|
0.14 mm²
|
2.5 mm²
|
0.14 mm²
|
2.5 mm²
|
26 AWG
|
12 AWG
|
10 mm
|
UL94-V0
|
CZ
|
10.31 g
|
2
|
|
||
|
PSLD 2.5, Snap on 2.5mm² linked double deck earth terminal
Art:
27037.2
Copied
|
2.5 mm²
|
Yellow/green
|
|
|
III
|
connected vertically
|
68.7 mm
|
5.1 mm
|
47.2 mm
|
45.7 mm
|
4
|
A3
|
0.14 mm²
|
4 mm²
|
0.14 mm²
|
2.5 mm²
|
0.14 mm²
|
2.5 mm²
|
26 AWG
|
12 AWG
|
10 mm
|
UL94-V0
|
CZ
|
13.87 g
|
2
|
|
||
|
PRKD 2.5/PE/L Grey, 2.5mm² double deck terminal, PE, Live
Art:
27051.6
Copied
|
2.5 mm²
|
Grey
|
500 V
|
22 A
|
III
|
|
68.7 mm
|
5.1 mm
|
47.2 mm
|
45.7 mm
|
2 x 2
|
A3
|
0.14 mm²
|
4 mm²
|
0.14 mm²
|
2.5 mm²
|
0.14 mm²
|
2.5 mm²
|
26 AWG
|
12 AWG
|
10 mm
|
UL94-V0
|
CZ
|
13.65 g
|
2
|
|
||
|
PRKD 2.5/PE/N Grey, 2.5mm² double deck terminal, PE, Neutral
Art:
27052.6
Copied
|
2.5 mm²
|
Grey
|
500 V
|
22 A
|
III
|
|
68.7 mm
|
5.1 mm
|
47.2 mm
|
45.7 mm
|
2 x 2
|
A3
|
0.14 mm²
|
4 mm²
|
0.14 mm²
|
2.5 mm²
|
0.14 mm²
|
2.5 mm²
|
26 AWG
|
12 AWG
|
10 mm
|
UL94-V0
|
CZ
|
13.65 g
|
2
|
|
||
|
PRKD 4 Grey, 4mm² Double deck terminal
Art:
27070.6
Copied
|
4 mm²
|
Grey
|
500 V
|
28 A
|
III
|
|
83 mm
|
6.1 mm
|
47.5 mm
|
47.5 mm
|
2 x 2
|
A4
|
0.34 mm²
|
6 mm²
|
0.34 mm²
|
6 mm²
|
0.34 mm²
|
4 mm²
|
22 AWG
|
10 AWG
|
12 mm
|
UL94-V0
|
CZ
|
14.99 g
|
2
|
|
||
|
PRKD 4 Blue, 4mm² Double deck terminal
Art:
27070.5
Copied
|
4 mm²
|
Blue
|
500 V
|
28 A
|
III
|
|
83 mm
|
6.1 mm
|
47.5 mm
|
47.5 mm
|
2 x 2
|
A4
|
0.34 mm²
|
6 mm²
|
0.34 mm²
|
6 mm²
|
0.34 mm²
|
4 mm²
|
22 AWG
|
10 AWG
|
12 mm
|
UL94-V0
|
CZ
|
14.99 g
|
2
|
|
||
|
PRKD 4/3A Grey, 4mm² Double deck terminal, 1 in 2 out
Art:
27073.6
Copied
|
4 mm²
|
Grey
|
500 V
|
28 A
|
III
|
|
103 mm
|
6.1 mm
|
47.5 mm
|
47.5 mm
|
2 x 3
|
A4
|
0.34 mm²
|
6 mm²
|
0.34 mm²
|
6 mm²
|
0.34 mm²
|
4 mm²
|
22 AWG
|
10 AWG
|
12 mm
|
UL94-V0
|
CZ
|
18 g
|
2
|
|
||
|
PRKD 4/3A Blue, 4mm² Double deck terminal, 1 in 2 out
Art:
27073.5
Copied
|
4 mm²
|
Blue
|
500 V
|
28 A
|
III
|
|
103 mm
|
6.1 mm
|
47.5 mm
|
47.5 mm
|
2 x 3
|
A4
|
0.34 mm²
|
6 mm²
|
0.34 mm²
|
6 mm²
|
0.34 mm²
|
4 mm²
|
22 AWG
|
10 AWG
|
12 mm
|
UL94-V0
|
CZ
|
18 g
|
2
|
|
||
|
PSLD 4, Snap on 4mm² linked double deck earth terminal 4 connections
Art:
27071.2
Copied
|
4 mm²
|
Green/yellow
|
500 V
|
22 A
|
3
|
|
75.7 mm
|
6.1 mm
|
50.3 mm
|
48.8 mm
|
2x2
|
A4
|
0.5 mm²
|
6 mm²
|
0.5 mm²
|
4 mm²
|
0.5 mm²
|
4 mm²
|
20 AWG
|
10 AWG
|
12 mm
|
V-0
|
DE
|
18.94 g
|
2
|
|
||
|
PSLD 4/3A, Snap on 4mm² linked double deck earth terminal, 6 connections
Art:
27074.2
Copied
|
4 mm²
|
Green/yellow
|
500 V
|
22 A
|
3
|
|
103 mm
|
6.1 mm
|
50.3 mm
|
48.8 mm
|
3x2
|
A4
|
0.5 mm²
|
6 mm²
|
0.5 mm²
|
4 mm²
|
0.5 mm²
|
4 mm²
|
20 AWG
|
10 AWG
|
12 mm
|
V-0
|
DE
|
25.07 g
|
3
|
|
Select a variant in the list