CONTA-CLIP
The FNT neutral disconnect terminals feature an integral mounting post for attaching the 10x3-mm neutral busbar.
No additional plates or fixings are required, Â as a secure contact to the busbar is made using the
no-screw slider for the neutral conductor.
With the FSLI protective earth terminals, the PE potential is connected via the PE foot (which contacts the DIN rail on both sides).
Solid wires and flexible wires with wire-end ferrules can be inserted into the connection mechanism without the need for tools.
The pressure spring opens automatically when the wire is inserted; this ensures a secure contact with the busbar.
A standard screwdriver can be used to open the clamp for release and for the insertion of stranded wire without ferrules.
This range can also be combined with the FDLIS three-level installation terminal range.
The one-level terminals – FRKI, FSLI, and FNT – can be used in combination with the three-level FDLIS installation terminals, as the height of the neutral busbar is identical in both versions.
Where the neutral busbar is not being used with the 16mm terminals, there is the FRK16 in the standard range, this has a central din rail mounting foot and provides a symmetrical layout.
Â
General data |
|
---|---|
Rated wire cross section | 4 mm² |
Colour | Beige |
Rated voltage IEC | 800 V |
Rated current IEC | 32 A |
Mounting | TS 35 |
Rated impulse voltage | 8 kV |
Overvoltage category | III |
Contamination degree | 3 |
Approvals | CSA, CSA US, KEMA KUR, EAC |
Dimensions |
|
Length | 52.5 mm |
Width | 5.1 mm |
Height TS 35/7.5 | 38.5 mm |
Height | 37.5 mm |
Connection data |
|
Connections | 2 |
Number of levels | 1 Â |
Plug gauge acc. EN 60 947-1 | A4 |
Cross connect channels | 2 Â |
Cross section single wire from | 0.5 mm² |
Cross section single wire to | 6 mm² |
Cross section stranded wire from | 0.6 mm² |
Cross section stranded wire to | 6 mm² |
Cross section stranded with ferrule from | 0.5 mm² |
*Invisible Heading* |
|
---|---|
Cross section stranded with ferrule to | 4 mm² |
Rated wire cross section from (AWG) | 20 |
Rated wire cross section to (AWG) | 10 |
Stripping length | 12 mm |
Materials |
|
Insulation material | Polyamide 6.6 |
Flammability class | UL94-V0 |
Operating temperature from | -40 °C |
Operating temperature to | 120 °C |
Approvals |
|
Rated voltage CSA | 600 V |
Rated current CSA | 28 A |
CSA test standard | C22.2 No 158 |
Rated voltage CSAus | 600 V |
Rated current CSAus | 28 A |
CSAus test standard | UL 1059 |
EAC test standard | TR ZU 004/2011 |
KEMA KEUR test standard | EN 60947-7-1:2009 |
Additional data |
|
Tariff code | 85369010 |
Country of origin | BG |
Weight | 8.25 g |
Pack size | 100 Â |
The FNT neutral disconnect terminals feature an integral mounting post for attaching the 10x3-mm neutral busbar.
No additional plates or fixings are required, Â as a secure contact to the busbar is made using the
no-screw slider for the neutral conductor.
With the FSLI protective earth terminals, the PE potential is connected via the PE foot (which contacts the DIN rail on both sides).
Solid wires and flexible wires with wire-end ferrules can be inserted into the connection mechanism without the need for tools.
The pressure spring opens automatically when the wire is inserted; this ensures a secure contact with the busbar.
A standard screwdriver can be used to open the clamp for release and for the insertion of stranded wire without ferrules.
This range can also be combined with the FDLIS three-level installation terminal range.
The one-level terminals – FRKI, FSLI, and FNT – can be used in combination with the three-level FDLIS installation terminals, as the height of the neutral busbar is identical in both versions.
Where the neutral busbar is not being used with the 16mm terminals, there is the FRK16 in the standard range, this has a central din rail mounting foot and provides a symmetrical layout.
Â
This innovative push-in connection system enables time savings of up to 50%, whether you're wiring control panels or managing complex installations
Solar energy has become a pillar of the global energy transition. The experts at OEM Automatic have broken down the role of photovoltaic fuses and their contribution to solar systems, as well as, how to choose the right solution for you.
Ultra fast-acting fuse links engineered specifically to shield delicate semiconductor devices.
Do you need reliable protection for measuring and control equipment? DEHN YellowLine delivers voltage surge protection tailored for building, measuring, and control systems
Choosing the right circuit breaker is important for protecting DC circuits. Two primary forms of protection are MCBs and ECBs. The experts at OEM Automatic breakdown the two circuit breakers for you!
New signal lights from Auer Signal are now available! The first products to be launched in this series are the Smart Dot 50 in the Basic and Standard versions, as well as the Smart Indicator 50 in the Basic version.Â
|
|
|
|
|
||
---|---|---|---|---|---|---|
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
Parts | Rated wire cross section | Colour | Rated voltage IEC | Rated current IEC | Rated impulse voltage | Approvals | Length | Width | Height TS 35/7.5 | Height | Connections | Plug gauge acc. EN 60 947-1 | Cross connect channels | Cross section single wire from | Cross section single wire to | Cross section stranded wire from | Cross section stranded wire to | Cross section stranded with ferrule from | Cross section stranded with ferrule to | Rated wire cross section from (AWG) | Rated wire cross section to (AWG) | Stripping length | Rated voltage UL | Rated current UL | UL test standard | Rated voltage CSA | Rated current CSA | CSA test standard | Rated voltage CSAus | Rated current CSAus | CSAus test standard | Rated voltage cUL | Rated current cUL | cUL test standard | EAC test standard | KEMA KEUR test standard | Country of origin | Weight | Pack size | Price | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]()
FRKI 2.5-4 Beige, 4mm² Installation feed through, push-in
Art:
3276.2
Copied
|
4 mm²
|
Beige
|
800 V
|
32 A
|
8 kV
|
CSA, CSA US, KEMA KUR, EAC
|
52.5 mm
|
5.1 mm
|
38.5 mm
|
37.5 mm
|
2
|
A4
|
2
|
0.5 mm²
|
6 mm²
|
0.6 mm²
|
6 mm²
|
0.5 mm²
|
4 mm²
|
20
|
10
|
12 mm
|
|
|
|
600 V
|
28 A
|
C22.2 No 158
|
600 V
|
28 A
|
UL 1059
|
|
|
|
TR ZU 004/2011
|
EN 60947-7-1:2009
|
BG
|
8.25 g
|
100
|
| ||
![]()
FRKI 2.5-4 Blue, 4mm² Installation feed through, push-in
Art:
3276.5
Copied
|
4 mm²
|
Blue
|
800 V
|
32 A
|
8 kV
|
CSA, CSA US, KEMA KUR, EAC
|
52.5 mm
|
5.1 mm
|
38.5 mm
|
37.5 mm
|
2
|
A4
|
2
|
0.5 mm²
|
6 mm²
|
0.6 mm²
|
6 mm²
|
0.5 mm²
|
4 mm²
|
20
|
10
|
12 mm
|
|
|
|
600 V
|
28 A
|
C22.2 No 158
|
600 V
|
28 A
|
UL 1059
|
|
|
|
TR ZU 004/2011
|
EN 60947-7-1:2009
|
BG
|
8.25 g
|
100
|
| ||
![]()
FRKI 2.5-4 Orange, 4mm² Installation feed through, push-in
Art:
3276.3
Copied
|
4 mm²
|
Orange
|
800 V
|
32 A
|
8 kV
|
CSA, CSA US, KEMA KUR, EAC
|
52.5 mm
|
5.1 mm
|
38.5 mm
|
37.5 mm
|
2
|
A4
|
2
|
0.5 mm²
|
6 mm²
|
0.6 mm²
|
6 mm²
|
0.5 mm²
|
4 mm²
|
20
|
10
|
12 mm
|
|
|
|
600 V
|
28 A
|
C22.2 No 158
|
600 V
|
28 A
|
UL 1059
|
|
|
|
TR ZU 004/2011
|
EN 60947-7-1:2009
|
BG
|
8.25 g
|
100
|
| ||
![]()
FSLI 2,5-4 GNYE
Art:
3279.2
Copied
|
4 mm²
|
Green/yellow
|
|
|
|
CSA, CSA US, KEMA KUR, EAC
|
52.5 mm
|
5.1 mm
|
38.5 mm
|
37.5 mm
|
2
|
A4
|
1
|
0.5 mm²
|
6 mm²
|
0.6 mm²
|
6 mm²
|
0.5 mm²
|
4 mm²
|
20
|
10
|
12 mm
|
|
|
|
|
|
C22.2 No 158
|
|
|
UL 1059
|
|
|
|
TR ZU 004/2011
|
EN 60947-7-2:2009
|
BG
|
11.25 g
|
100
|
| ||
![]()
FNT 2,5-4 BU
Art:
3273.5
Copied
|
4 mm²
|
Blue
|
250 V
|
32 A
|
8 kV
|
KEMA KUR
|
64 mm
|
5.1 mm
|
42.5 mm
|
41.5 mm
|
1
|
A4
|
1
|
0.5 mm²
|
6 mm²
|
0.6 mm²
|
6 mm²
|
0.5 mm²
|
4 mm²
|
20
|
10
|
12 mm
|
|
|
|
|
|
|
|
|
|
|
|
|
|
EN 60947-7-1:2009
|
BG
|
9.25 g
|
100
|
| ||
![]()
FRKI 6-10 Beige, 10mm² Installation feed through, push-in
Art:
3277.2
Copied
|
10 mm²
|
Beige
|
800 V
|
57 A
|
8 kV
|
CSA, CSA US, KEMA KUR, EAC
|
56.5 mm
|
8.1 mm
|
40.5 mm
|
39.8 mm
|
2
|
A5
|
2
|
1.5 mm²
|
10 mm²
|
1.5 mm²
|
10 mm²
|
1.5 mm²
|
10 mm²
|
22
|
10
|
12 mm
|
|
|
|
600 V
|
44 A
|
C22.2 No 158
|
600 V
|
44 A
|
UL 1059
|
|
|
|
TR ZU 004/2011
|
EN 60947-7-1:2009
|
BG
|
14.25 g
|
100
|
| ||
![]()
FRKI 6-10 Blue, 10mm² Installation feed through, push-in
Art:
3277.5
Copied
|
10 mm²
|
Blue
|
800 V
|
57 A
|
8 kV
|
CSA, CSA US, KEMA KUR, EAC
|
56.5 mm
|
8.1 mm
|
40.5 mm
|
39.8 mm
|
2
|
A5
|
2
|
1.5 mm²
|
10 mm²
|
1.5 mm²
|
10 mm²
|
1.5 mm²
|
10 mm²
|
22
|
10
|
12 mm
|
|
|
|
600 V
|
44 A
|
C22.2 No 158
|
600 V
|
44 A
|
UL 1059
|
|
|
|
TR ZU 004/2011
|
EN 60947-7-1:2009
|
BG
|
14.25 g
|
100
|
| ||
![]()
FRKI 6-10 Orange, 10mm² Installation feed through, push-in
Art:
3277.3
Copied
|
10 mm²
|
Orange
|
800 V
|
57 A
|
8 kV
|
CSA, CSA US, KEMA KUR, EAC
|
56.5 mm
|
8.1 mm
|
40.5 mm
|
39.8 mm
|
2
|
A5
|
2
|
1.5 mm²
|
10 mm²
|
1.5 mm²
|
10 mm²
|
1.5 mm²
|
10 mm²
|
22
|
10
|
12 mm
|
|
|
|
600 V
|
44 A
|
C22.2 No 158
|
600 V
|
44 A
|
UL 1059
|
|
|
|
TR ZU 004/2011
|
EN 60947-7-1:2009
|
BG
|
14.25 g
|
100
|
| ||
![]()
FRKI 6-10 RD
Art:
3277.9
Copied
|
10 mm²
|
Red
|
800 V
|
57 A
|
8 kV
|
CSA, CSA US, KEMA KUR, EAC
|
56.5 mm
|
8.1 mm
|
40.5 mm
|
39.8 mm
|
2
|
A5
|
2
|
1.5 mm²
|
10 mm²
|
1.5 mm²
|
10 mm²
|
1.5 mm²
|
10 mm²
|
22
|
10
|
12 mm
|
|
|
|
600 V
|
44 A
|
C22.2 No 158
|
600 V
|
44 A
|
UL 1059
|
|
|
|
TR ZU 004/2011
|
EN 60947-7-1:2009
|
CZ
|
14.25 g
|
100
|
| ||
![]()
FSLI 6-10 GNYE
Art:
3280.2
Copied
|
10 mm²
|
Green/yellow
|
|
|
|
CSA, CSA US, KEMA KUR, EAC
|
56.5 mm
|
8.1 mm
|
40.5 mm
|
39.8 mm
|
2
|
A5
|
1
|
1.5 mm²
|
10 mm²
|
1.5 mm²
|
10 mm²
|
1.5 mm²
|
10 mm²
|
22
|
10
|
12 mm
|
|
|
|
|
|
C22.2 No 158
|
|
|
UL 1059
|
|
|
|
TR ZU 004/2011
|
EN 60947-7-2:2009
|
BG
|
20.25 g
|
100
|
| ||
![]()
FNT 6-10 BU
Art:
3274.5
Copied
|
10 mm²
|
Blue
|
250 V
|
57 A
|
8 kV
|
KEMA KUR
|
67.5 mm
|
8.1 mm
|
40.5 mm
|
39.8 mm
|
1
|
A5
|
1
|
1.5 mm²
|
10 mm²
|
1.5 mm²
|
10 mm²
|
1.5 mm²
|
10 mm²
|
22
|
10
|
12 mm
|
|
|
|
|
|
|
|
|
|
|
|
|
|
EN 60947-7-1:2009
|
BG
|
16.25 g
|
100
|
| ||
![]()
FRKI 6-10/3A BG
Art:
3216.2
Copied
|
10 mm²
|
Beige
|
800 V
|
57 A
|
8 kV
|
EAC
|
82.4 mm
|
8.1 mm
|
39.8 mm
|
|
3
|
A3
|
2
|
1.5 mm²
|
10 mm²
|
1.5 mm²
|
10 mm²
|
1.5 mm²
|
10 mm²
|
16
|
8
|
12 mm
|
600 V
|
44 A
|
UL 1059
|
|
|
|
|
|
|
44 V
|
600 A
|
C22.2 No 158
|
TR ZU 004/2011
|
EN 60947-7-1:2009
|
BG
|
27.09 g
|
50
|
| ||
![]()
FRKI 6-10/3A BU
Art:
3216.5
Copied
|
10 mm²
|
Blue
|
800 V
|
57 A
|
8 kV
|
EAC
|
82.4 mm
|
8.1 mm
|
39.8 mm
|
|
3
|
A3
|
2
|
1.5 mm²
|
10 mm²
|
1.5 mm²
|
10 mm²
|
1.5 mm²
|
10 mm²
|
16
|
8
|
12 mm
|
600 V
|
44 A
|
UL 1059
|
|
|
|
|
|
|
44 V
|
600 A
|
C22.2 No 158
|
TR ZU 004/2011
|
EN 60947-7-1:2009
|
BG
|
27.09 g
|
50
|
| ||
![]()
FRKI 6-10/3A OG
Art:
3216.3
Copied
|
10 mm²
|
Orange
|
800 V
|
57 A
|
8 kV
|
EAC
|
82.4 mm
|
8.1 mm
|
39.8 mm
|
|
3
|
A3
|
2
|
1.5 mm²
|
10 mm²
|
1.5 mm²
|
10 mm²
|
1.5 mm²
|
10 mm²
|
16
|
8
|
12 mm
|
600 V
|
44 A
|
UL 1059
|
|
|
|
|
|
|
44 V
|
600 A
|
C22.2 No 158
|
TR ZU 004/2011
|
EN 60947-7-1:2009
|
BG
|
27.09 g
|
50
|
| ||
![]()
FSLI 6-10/3A GNYE
Art:
3217.2
Copied
|
10 mm²
|
Green/yellow
|
|
|
|
EAC
|
82.4 mm
|
8.1 mm
|
39.8 mm
|
|
3
|
A3
|
2
|
1.5 mm²
|
10 mm²
|
1.5 mm²
|
10 mm²
|
1.5 mm²
|
10 mm²
|
16
|
8
|
12 mm
|
|
|
UL 1059
|
|
|
|
|
|
|
|
|
C22.2 No 158
|
TR ZU 004/2011
|
EN 60947-7-2:2009
|
BG
|
33.87 g
|
50
|
| ||
![]()
FRKI 16/2A BG
Art:
3278.2
Copied
|
16 mm²
|
Beige
|
1000 V
|
76 A
|
8 kV
|
EAC
|
72.4 mm
|
12.1 mm
|
49 mm
|
48 mm
|
2
|
A7
|
2
|
2.5 mm²
|
25 mm²
|
2.5 mm²
|
25 mm²
|
2.5 mm²
|
16 mm²
|
14
|
4
|
18 mm
|
600 V
|
75 A
|
UL 1059
|
|
|
|
|
|
|
75 V
|
600 A
|
C22.2 No 158
|
TR ZU 004/2011
|
EN 60947-7-1:2009
|
CZ
|
17.8 g
|
50
|
| ||
![]()
FRKI 16/2A BU
Art:
3278.5
Copied
|
16 mm²
|
Blue
|
1000 V
|
76 A
|
8 kV
|
EAC
|
72.4 mm
|
12.1 mm
|
49 mm
|
48 mm
|
2
|
A7
|
2
|
2.5 mm²
|
25 mm²
|
2.5 mm²
|
25 mm²
|
2.5 mm²
|
16 mm²
|
14
|
4
|
18 mm
|
600 V
|
75 A
|
UL 1059
|
|
|
|
|
|
|
75 V
|
600 A
|
C22.2 No 158
|
TR ZU 004/2011
|
EN 60947-7-1:2009
|
CZ
|
17.8 g
|
50
|
| ||
![]()
FRKI 16/2A OG
Art:
3278.3
Copied
|
16 mm²
|
Orange
|
1000 V
|
76 A
|
8 kV
|
EAC
|
72.4 mm
|
12.1 mm
|
49 mm
|
48 mm
|
2
|
A7
|
2
|
2.5 mm²
|
25 mm²
|
2.5 mm²
|
25 mm²
|
2.5 mm²
|
16 mm²
|
14
|
4
|
18 mm
|
600 V
|
75 A
|
UL 1059
|
|
|
|
|
|
|
75 V
|
600 A
|
C22.2 No 158
|
TR ZU 004/2011
|
EN 60947-7-1:2009
|
CZ
|
17.8 g
|
50
|
| ||
![]()
FSLI 16/2A GNYE
Art:
3281.2
Copied
|
16 mm²
|
Green/yellow
|
|
|
|
EAC
|
72.4 mm
|
12.1 mm
|
49 mm
|
48 mm
|
2
|
A7
|
1
|
2.5 mm²
|
25 mm²
|
2.5 mm²
|
25 mm²
|
2.5 mm²
|
16 mm²
|
14
|
4
|
18 mm
|
|
|
UL 1059
|
|
|
|
|
|
|
|
|
C22.2 No 158
|
TR ZU 004/2011
|
EN 60947-7-2:2009
|
CZ
|
44.7 g
|
50
|
|