CONTA-CLIP
 The FDLIS series is a compact terminal designed for the distribution of power.
Â
The range consists of six different blocks that can be used in single or 3 phase installation of up to 32A
Solid wires or stranded cables with ferrules can be directly inserted into the terminals without the need of any tools.
These blocks include a version that connects directly to the din rail for the Earth connection.
Â
Where there is a need to disconnect the Neutral circuit, without the removal of the cables, there is a neutral disconnect terminal that is designed to accommodate a 10 x 3 mm neutral busbar. There is no need for an additional fixing plate because the NT terminal snaps the neutral busbar securely into place.
Â
General data |
|
---|---|
Rated wire cross section | 4 mm² |
Colour | Beige |
Rated voltage IEC | 400 V |
Rated current IEC | 32 A |
Load current max | 32 A |
Mounting | TS 35 |
Rated impulse voltage | 6 kV |
Overvoltage category | III |
Contamination degree | 3 |
Approvals | CSA, CSA US, KEMA KUR, EAC |
Dimensions |
|
Length | 100 mm |
Width | 5.1 mm |
Height TS 35/7.5 | 49 mm |
Connection data |
|
Connections | 4 |
Special connections | Busbar 10 x 3mm |
Plug gauge acc. EN 60 947-1 | A3 |
Cross connect channels | 2 Â |
Cross section single wire from | 0.2 mm² |
Cross section single wire to | 4 mm² |
Cross section stranded wire from | 0.2 mm² |
Cross section stranded wire to | 4 mm² |
*Invisible Heading* |
|
---|---|
Cross section stranded with ferrule from | 0.2 mm² |
Cross section stranded with ferrule to | 2.5 mm² |
Rated wire cross section from (AWG) | 26 |
Rated wire cross section to (AWG) | 10 |
Stripping length | 12 mm |
Materials |
|
Insulation material | Polyamide 6.6 |
Flammability class | UL94-V0 |
Operating temperature from | -40 °C |
Operating temperature to | 120 °C |
Approvals |
|
Rated voltage CSA | 300 V |
Rated current CSA | 25 A |
CSA test standard | C22.2 No 158 |
Rated voltage CSAus | 300 V |
Rated current CSAus | 25 A |
CSAus test standard | UL 1059 |
EAC test standard | TR ZU 004/2011 |
Additional data |
|
Tariff code | 85369010 |
Country of origin | BG |
Weight | 21 g |
Pack size | 50 Â |
 The FDLIS series is a compact terminal designed for the distribution of power.
Â
The range consists of six different blocks that can be used in single or 3 phase installation of up to 32A
Solid wires or stranded cables with ferrules can be directly inserted into the terminals without the need of any tools.
These blocks include a version that connects directly to the din rail for the Earth connection.
Â
Where there is a need to disconnect the Neutral circuit, without the removal of the cables, there is a neutral disconnect terminal that is designed to accommodate a 10 x 3 mm neutral busbar. There is no need for an additional fixing plate because the NT terminal snaps the neutral busbar securely into place.
Â
This innovative push-in connection system enables time savings of up to 50%, whether you're wiring control panels or managing complex installations
Solar energy has become a pillar of the global energy transition. The experts at OEM Automatic have broken down the role of photovoltaic fuses and their contribution to solar systems, as well as, how to choose the right solution for you.
Ultra fast-acting fuse links engineered specifically to shield delicate semiconductor devices.
Do you need reliable protection for measuring and control equipment? DEHN YellowLine delivers voltage surge protection tailored for building, measuring, and control systems
Choosing the right circuit breaker is important for protecting DC circuits. Two primary forms of protection are MCBs and ECBs. The experts at OEM Automatic breakdown the two circuit breakers for you!
New signal lights from Auer Signal are now available! The first products to be launched in this series are the Smart Dot 50 in the Basic and Standard versions, as well as the Smart Indicator 50 in the Basic version.Â
|
|
|
|
|
||
---|---|---|---|---|---|---|
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
Parts | Additional information | Width | Connections | Special connections | KEMA KEUR test standard | Weight | Pack size | Price | ||
---|---|---|---|---|---|---|---|---|---|---|
![]()
FDLIS 2,5-4 NT/L/PE
Art:
3240.2
Copied
|
|
5.1 mm
|
4
|
Busbar 10 x 3mm
|
|
21 g
|
50
|
| ||
![]()
FDLIS 2,5-4 N/L/PE
Art:
3241.2
Copied
|
|
5.1 mm
|
5
|
|
|
21 g
|
50
|
| ||
![]()
FDLIS 2,5-4 L/L/PE
Art:
3242.2
Copied
|
|
5.1 mm
|
5
|
|
|
21 g
|
50
|
| ||
![]()
FDLIS 2,5-4 N/L
Art:
3243.2
Copied
|
|
5.1 mm
|
4
|
|
EN 60947-7-1:2009
|
15.4 g
|
50
|
| ||
![]()
FDLIS 2,5-4 L/L
Art:
3244.2
Copied
|
|
5.1 mm
|
4
|
|
EN 60947-7-1:2009
|
15.4 g
|
50
|
| ||
![]()
FDLIS 2,5-4 N
Art:
3245.2
Copied
|
|
5.1 mm
|
2
|
|
EN 60947-7-1:2009
|
11 g
|
50
|
| ||
![]()
FDLIS 2,5-4 L
Art:
3246.2
Copied
|
|
5.1 mm
|
2
|
|
EN 60947-7-1:2009
|
10 g
|
50
|
| ||
![]()
FDLIS B 2,5-4 3NT/3L/3PE
Art:
3247.2
Copied
|
block for AC application
|
15.3 mm
|
12
|
Busbar 10 x 3mm
|
|
63 g
|
16
|
| ||
![]()
FDLIS B 2,5-4 NT/3L/PE
Art:
3248.2
Copied
|
block for 3-phase application
|
10.2 mm
|
7
|
Busbar 10 x 3mm
|
|
35.78 g
|
25
|
| ||
![]()
FDLIS B 2,5-4 3L/3N/3PE
Art:
3249.2
Copied
|
block for AC application
|
15.3 mm
|
15
|
|
|
62 g
|
16
|
| ||
![]()
FDLIS B 2,5-4 3L/N/PE
Art:
3250.2
Copied
|
block for 3-phase application
|
10.2 mm
|
9
|
|
|
37 g
|
25
|
| ||
![]()
FDLIS B 2,5-4 6L
Art:
3251.2
Copied
|
|
15.3 mm
|
12
|
|
EN 60947-7-1:2009
|
47.2 g
|
16
|
| ||
![]()
FDLIS B 2,5-4 6L/3PE
Art:
3252.2
Copied
|
|
15.3 mm
|
15
|
|
|
62 g
|
16
|
|
Select a variant in the list