CONTA-CLIP
The ZTRK 2.5 mm² disconnect terminal is a tension-spring based DIN-rail module, ideal for streamlined wiring. It supports up to 2.5 mm² conductors, rated for 400 V / 18 A under IEC standards, with an impulse voltage tolerance of 6 kV and overvoltage category III. With a compact 5.1 mm width, 68 mm length, and 42.3 mm height, it mounts easily on TS 35/7.5 rails. Constructed in flame-retardant beige polyamide and backed by CSA, CSA US, and KEMA-Keur approvals, it ensures safe and code-compliant operation in industrial cabinets. The tension-spring clamp mechanism offers fast, tool-free conductor insertion and high connection stability, even under vibration, a standout feature of CONTA-CONNECT’s tension-spring range.
In application, ZTRK terminals excel in control panels and machinery where isolation between circuits or loads is frequently required. The integrated disconnect blade enables easy circuit interruption for testing or maintenance without disturbing other lines. Its narrow profile is perfect for high-density installations, while the tension-spring clamp speeds up installation, ideal for field engineers and production lines. With its robust insulation (contamination degree 3) and test-ready design, ZTRK is a reliable, efficient solution for streamlined, safety-conscious DIN-rail wiring systems.Â
General data |
|
---|---|
Rated wire cross section | 2.5 mm² |
Colour | Green |
Rated voltage IEC | 500 V |
Rated current IEC | 24 A |
Mounting | TS 35 |
Rated impulse voltage | 6 kV |
Overvoltage category | III |
Contamination degree | 3 |
Approvals | UL, CSA, GL, CSA US, KEMA KUR, EAC |
Dimensions |
|
Length | 83.6 mm |
Width | 5.1 mm |
Height TS 35/7.5 | 53 mm |
Connection data |
|
Connections | 2 x 2 |
Number of levels | 2 Â |
Plug gauge acc. EN 60 947-1 | A3 |
Cross connect channels | 2 Â |
Number of test pick off options | 4 Â |
Cross section single wire from | 0.5 mm² |
Cross section single wire to | 4 mm² |
Cross section stranded wire from | 0.5 mm² |
Cross section stranded wire to | 4 mm² |
Cross section stranded with ferrule from | 0.5 mm² |
Cross section stranded with ferrule to | 2.5 mm² |
Rated wire cross section from (AWG) | 20 |
*Invisible Heading* |
|
---|---|
Rated wire cross section to (AWG) | 12 |
Stripping length | 10 mm |
Materials |
|
Insulation material | Polyamide 6.6 |
Flammability class | UL94-V0 |
Operating temperature from | -40 °C |
Operating temperature to | 120 °C |
Approvals |
|
Rated voltage UL | 300 V |
Rated current UL | 10 A |
UL test standard | UL 1059 |
Rated voltage CSA | 300 V |
Rated current CSA | 10 A |
CSA test standard | C22.2 No 158 |
Rated voltage CSAus | 300 V |
Rated current CSAus | 10 A |
CSAus test standard | UL 1059 |
GL test standard | IEC 60947-7-1:2009 |
EAC test standard | TR ZU 004/2011 |
KEMA KEUR test standard | EN 60947-7-1:2009 |
Additional data |
|
Tariff code | 85369010 |
Country of origin | CZ |
Weight | 12.8 g |
Pack size | 100 Â |
The ZTRK 2.5 mm² disconnect terminal is a tension-spring based DIN-rail module, ideal for streamlined wiring. It supports up to 2.5 mm² conductors, rated for 400 V / 18 A under IEC standards, with an impulse voltage tolerance of 6 kV and overvoltage category III. With a compact 5.1 mm width, 68 mm length, and 42.3 mm height, it mounts easily on TS 35/7.5 rails. Constructed in flame-retardant beige polyamide and backed by CSA, CSA US, and KEMA-Keur approvals, it ensures safe and code-compliant operation in industrial cabinets. The tension-spring clamp mechanism offers fast, tool-free conductor insertion and high connection stability, even under vibration, a standout feature of CONTA-CONNECT’s tension-spring range.
In application, ZTRK terminals excel in control panels and machinery where isolation between circuits or loads is frequently required. The integrated disconnect blade enables easy circuit interruption for testing or maintenance without disturbing other lines. Its narrow profile is perfect for high-density installations, while the tension-spring clamp speeds up installation, ideal for field engineers and production lines. With its robust insulation (contamination degree 3) and test-ready design, ZTRK is a reliable, efficient solution for streamlined, safety-conscious DIN-rail wiring systems.Â
This innovative push-in connection system enables time savings of up to 50%, whether you're wiring control panels or managing complex installations
Solar energy has become a pillar of the global energy transition. The experts at OEM Automatic have broken down the role of photovoltaic fuses and their contribution to solar systems, as well as, how to choose the right solution for you.
Ultra fast-acting fuse links engineered specifically to shield delicate semiconductor devices.
Do you need reliable protection for measuring and control equipment? DEHN YellowLine delivers voltage surge protection tailored for building, measuring, and control systems
Choosing the right circuit breaker is important for protecting DC circuits. Two primary forms of protection are MCBs and ECBs. The experts at OEM Automatic breakdown the two circuit breakers for you!
New signal lights from Auer Signal are now available! The first products to be launched in this series are the Smart Dot 50 in the Basic and Standard versions, as well as the Smart Indicator 50 in the Basic version.Â
|
|
|
|
|
||
---|---|---|---|---|---|---|
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
Parts | Colour | Rated voltage IEC | Rated current IEC | Diode type | Approvals | Explosion proof | Additional information | Connections | Cross connect channels | Number of test pick off options | Rated voltage UL | Rated current UL | UL test standard | Rated voltage CSA | Rated current CSA | CSA test standard | Rated voltage CSAus | Rated current CSAus | CSAus test standard | GL test standard | KEMA KEUR test standard | Country of origin | Weight | Price | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]()
ZRKD 2,5 GN
Art:
3562.1
Copied
|
Green
|
500 V
|
24 A
|
|
UL, CSA, GL, CSA US, KEMA KUR, EAC
|
|
|
2 x 2
|
2
|
4
|
300 V
|
10 A
|
UL 1059
|
300 V
|
10 A
|
C22.2 No 158
|
300 V
|
10 A
|
UL 1059
|
IEC 60947-7-1:2009
|
EN 60947-7-1:2009
|
CZ
|
12.8 g
|
| ||
![]()
ZRKD 2,5 BG
Art:
3562.2
Copied
|
Beige
|
500 V
|
24 A
|
|
UL, CSA, GL, CSA US, KEMA KUR, EAC
|
|
|
2 x 2
|
2
|
4
|
300 V
|
10 A
|
UL 1059
|
300 V
|
10 A
|
C22.2 No 158
|
300 V
|
10 A
|
UL 1059
|
IEC 60947-7-1:2009
|
EN 60947-7-1:2009
|
CZ
|
12.8 g
|
| ||
![]()
ZRKD 2,5 OG
Art:
3562.3
Copied
|
Orange
|
500 V
|
24 A
|
|
UL, CSA, GL, CSA US, KEMA KUR, EAC
|
|
|
2 x 2
|
2
|
4
|
300 V
|
10 A
|
UL 1059
|
300 V
|
10 A
|
C22.2 No 158
|
300 V
|
10 A
|
UL 1059
|
IEC 60947-7-1:2009
|
EN 60947-7-1:2009
|
CZ
|
12.72 g
|
| ||
![]()
ZRKD 2,5 BU
Art:
3562.5
Copied
|
Blue
|
500 V
|
24 A
|
|
UL, CSA, GL, CSA US, KEMA KUR, EAC
|
|
|
2 x 2
|
2
|
4
|
300 V
|
10 A
|
UL 1059
|
300 V
|
10 A
|
C22.2 No 158
|
300 V
|
10 A
|
UL 1059
|
IEC 60947-7-1:2009
|
EN 60947-7-1:2009
|
CZ
|
12.8 g
|
| ||
![]()
ZRKD 2,5 GR
Art:
3562.6
Copied
|
Grey
|
500 V
|
24 A
|
|
UL, CSA, GL, CSA US, KEMA KUR, EAC
|
|
|
2 x 2
|
2
|
4
|
300 V
|
10 A
|
UL 1059
|
300 V
|
10 A
|
C22.2 No 158
|
300 V
|
10 A
|
UL 1059
|
IEC 60947-7-1:2009
|
EN 60947-7-1:2009
|
CZ
|
12.8 g
|
| ||
![]()
ZRKD 2,5 YE
Art:
3562.8
Copied
|
Yellow
|
500 V
|
24 A
|
|
UL, CSA, GL, CSA US, KEMA KUR, EAC
|
|
|
2 x 2
|
2
|
4
|
300 V
|
10 A
|
UL 1059
|
300 V
|
10 A
|
C22.2 No 158
|
300 V
|
10 A
|
UL 1059
|
IEC 60947-7-1:2009
|
EN 60947-7-1:2009
|
CZ
|
12.8 g
|
| ||
![]()
ZRKD 2,5 RD
Art:
3562.9
Copied
|
Red
|
500 V
|
24 A
|
|
UL, CSA, GL, CSA US, KEMA KUR, EAC
|
|
|
2 x 2
|
2
|
4
|
300 V
|
10 A
|
UL 1059
|
300 V
|
10 A
|
C22.2 No 158
|
300 V
|
10 A
|
UL 1059
|
IEC 60947-7-1:2009
|
EN 60947-7-1:2009
|
CZ
|
12.8 g
|
| ||
![]()
ZRKD 2,5/SV BG
Art:
3563.2
Copied
|
Beige
|
500 V
|
24 A
|
|
UL, CSA, GL, CSA US, KEMA KUR, EAC
|
|
connected vertically
|
4
|
1
|
4
|
300 V
|
10 A
|
UL 1059
|
300 V
|
10 A
|
C22.2 No 158
|
300 V
|
10 A
|
UL 1059
|
IEC 60947-7-1:2009
|
EN 60947-7-1:2009
|
CZ
|
14.64 g
|
| ||
![]()
ZRKD 2,5/SV OG
Art:
3563.3
Copied
|
Orange
|
500 V
|
24 A
|
|
UL, CSA, GL, CSA US, KEMA KUR, EAC
|
|
connected vertically
|
4
|
1
|
4
|
300 V
|
10 A
|
UL 1059
|
300 V
|
10 A
|
C22.2 No 158
|
300 V
|
10 A
|
UL 1059
|
IEC 60947-7-1:2009
|
EN 60947-7-1:2009
|
CZ
|
12.8 g
|
| ||
![]()
ZRKD 2,5/SV BU
Art:
3563.5
Copied
|
Blue
|
500 V
|
24 A
|
|
UL, CSA, GL, CSA US, KEMA KUR, EAC
|
|
connected vertically
|
4
|
1
|
4
|
300 V
|
10 A
|
UL 1059
|
300 V
|
10 A
|
C22.2 No 158
|
300 V
|
10 A
|
UL 1059
|
IEC 60947-7-1:2009
|
EN 60947-7-1:2009
|
CZ
|
15.1 g
|
| ||
![]()
ZRKD 2,5/N/DU
Art:
3564.2
Copied
|
Beige
|
500 V
|
24 A
|
|
UL, CSA, GL, CSA US, KEMA KUR, EAC
|
|
|
2 x 2
|
2
|
4
|
300 V
|
10 A
|
UL 1059
|
300 V
|
10 A
|
C22.2 No 158
|
300 V
|
10 A
|
UL 1059
|
IEC 60947-7-1:2009
|
EN 60947-7-1:2009
|
CZ
|
13 g
|
| ||
![]()
ZRKD 2,5/DU/PE
Art:
3565.2
Copied
|
Beige
|
500 V
|
24 A
|
|
UL, CSA, GL, CSA US, KEMA KUR, EAC
|
|
|
2 x 2
|
1
|
4
|
300 V
|
10 A
|
UL 1059
|
300 V
|
10 A
|
C22.2 No 158
|
300 V
|
10 A
|
UL 1059
|
IEC 60947-7-1:2009
|
EN 60947-7-1:2009, EN 60947-7-2:2009
|
CZ
|
17.6 g
|
| ||
![]()
ZRKD 2,5/N/PE
Art:
3566.2
Copied
|
Beige
|
500 V
|
24 A
|
|
UL, CSA, GL, CSA US, KEMA KUR, EAC
|
|
|
2 x 2
|
1
|
4
|
300 V
|
10 A
|
UL 1059
|
300 V
|
10 A
|
C22.2 No 158
|
300 V
|
10 A
|
UL 1059
|
IEC 60947-7-1:2009
|
EN 60947-7-1:2009, EN 60947-7-2:2009
|
CZ
|
17.6 g
|
| ||
![]()
ZRKD 2,5/LED1(RD)/24V DC BG
Art:
3568.2
Copied
|
Beige
|
24 V
|
24 A
|
|
UL, CSA, CSA US, KEMA KUR, EAC
|
|
with LED status display
|
2 x 2
|
1
|
0
|
|
|
UL 1059
|
24 V
|
10 A
|
C22.2 No 158
|
24 V
|
10 A
|
UL 1059
|
|
EN 60947-7-1:2009
|
BG
|
13.2 g
|
| ||
![]()
ZRKD 2,5/LED2(RD)/24V DC BG
Art:
3569.2
Copied
|
Beige
|
24 V
|
24 A
|
|
UL, CSA, CSA US, KEMA KUR, EAC
|
|
with LED status display
|
2 x 2
|
1
|
0
|
|
|
UL 1059
|
24 V
|
10 A
|
C22.2 No 158
|
24 V
|
10 A
|
UL 1059
|
|
EN 60947-7-1:2009
|
BG
|
13.2 g
|
| ||
![]()
ZRKD 2,5/D1 BG
Art:
3570.2
Copied
|
Beige
|
500 V
|
1 A
|
1N4007 / 1000V / 1A
|
UL, CSA, CSA US, KEMA KUR, EAC
|
|
with diodes
|
2 x 2
|
1
|
0
|
300 V
|
1 A
|
UL 1059
|
300 V
|
1 A
|
C22.2 No 158
|
300 V
|
1 A
|
UL 1059
|
|
EN 60947-7-1:2009
|
BG
|
13.2 g
|
| ||
![]()
ZRKD 2,5/D1 OG
Art:
3570.3
Copied
|
Orange
|
500 V
|
1 A
|
1N4007 / 1000V / 1A
|
UL, CSA, CSA US, KEMA KUR, EAC
|
|
with diodes
|
2 x 2
|
1
|
0
|
300 V
|
1 A
|
UL 1059
|
300 V
|
1 A
|
C22.2 No 158
|
300 V
|
1 A
|
UL 1059
|
|
EN 60947-7-1:2009
|
BG
|
13.2 g
|
| ||
![]()
ZRKD 2,5/D2 BG
Art:
3571.2
Copied
|
Beige
|
500 V
|
1 A
|
1N4007 / 1000V / 1A
|
UL, CSA, CSA US, KEMA KUR, EAC
|
|
with diodes
|
2 x 2
|
1
|
0
|
300 V
|
1 A
|
UL 1059
|
300 V
|
1 A
|
C22.2 No 158
|
300 V
|
1 A
|
UL 1059
|
|
EN 60947-7-1:2009
|
BG
|
12.35 g
|
| ||
![]()
ZRKD 2,5/D2 GR
Art:
3571.6
Copied
|
Grey
|
500 V
|
1 A
|
1N4007 / 1000V / 1A
|
UL, CSA, CSA US, KEMA KUR, EAC
|
|
with diodes
|
2 x 2
|
1
|
0
|
300 V
|
1 A
|
UL 1059
|
300 V
|
1 A
|
C22.2 No 158
|
300 V
|
1 A
|
UL 1059
|
|
EN 60947-7-1:2009
|
BG
|
13.2 g
|
| ||
![]()
ZRKD 2,5/D3 BG
Art:
3572.2
Copied
|
Beige
|
500 V
|
1 A
|
1N4007 / 1000V / 1A
|
UL, CSA, CSA US, KEMA KUR, EAC
|
|
with diodes
|
2 x 2
|
1
|
0
|
300 V
|
1 A
|
UL 1059
|
300 V
|
1 A
|
C22.2 No 158
|
300 V
|
1 A
|
UL 1059
|
|
EN 60947-7-1:2009
|
BG
|
13.2 g
|
| ||
![]()
ZRKD 2,5/D4 BG
Art:
3573.2
Copied
|
Beige
|
500 V
|
1 A
|
1N4007 / 1000V / 1A
|
UL, CSA, CSA US, KEMA KUR, EAC
|
|
with diodes
|
2 x 2
|
1
|
0
|
300 V
|
1 A
|
UL 1059
|
300 V
|
1 A
|
C22.2 No 158
|
300 V
|
1 A
|
UL 1059
|
|
EN 60947-7-1:2009
|
BG
|
13.2 g
|
| ||
![]()
ZRKD 2,5/D4 GR
Art:
3573.6
Copied
|
Grey
|
500 V
|
1 A
|
1N4007 / 1000V / 1A
|
UL, CSA, CSA US, KEMA KUR, EAC
|
|
with diodes
|
2 x 2
|
1
|
0
|
300 V
|
1 A
|
UL 1059
|
300 V
|
1 A
|
C22.2 No 158
|
300 V
|
1 A
|
UL 1059
|
|
EN 60947-7-1:2009
|
BG
|
13.2 g
|
| ||
![]()
ZRKD 2,5/D5 BG
Art:
3574.2
Copied
|
Beige
|
500 V
|
1 A
|
1N4007 / 1000V / 1A
|
UL, CSA, CSA US, KEMA KUR, EAC
|
|
with diodes
|
2 x 2
|
1
|
0
|
300 V
|
1 A
|
UL 1059
|
300 V
|
1 A
|
C22.2 No 158
|
300 V
|
1 A
|
UL 1059
|
|
EN 60947-7-1:2009
|
BG
|
13.2 g
|
| ||
![]()
ZRKD 2,5/ZBA GN
Art:
3575.1
Copied
|
Green
|
500 V
|
24 A
|
|
UL, CSA, GL, CSA US, KEMA KUR, EAC
|
|
|
2 x 2
|
2
|
4
|
300 V
|
10 A
|
UL 1059
|
300 V
|
10 A
|
C22.2 No 158
|
300 V
|
10 A
|
UL 1059
|
IEC 60947-7-1:2009
|
EN 60947-7-1:2009
|
DE
|
13.97 g
|
| ||
![]()
ZRKD 2,5/ZBA BG
Art:
3575.2
Copied
|
Beige
|
500 V
|
24 A
|
|
UL, CSA, GL, CSA US, KEMA KUR, EAC
|
|
|
2 x 2
|
2
|
4
|
300 V
|
10 A
|
UL 1059
|
300 V
|
10 A
|
C22.2 No 158
|
300 V
|
10 A
|
UL 1059
|
IEC 60947-7-1:2009
|
EN 60947-7-1:2009
|
DE
|
13.97 g
|
| ||
![]()
ZRKD 2,5/ZBA OG
Art:
3575.3
Copied
|
Orange
|
500 V
|
24 A
|
|
UL, CSA, GL, CSA US, KEMA KUR, EAC
|
|
|
2 x 2
|
2
|
4
|
300 V
|
10 A
|
UL 1059
|
300 V
|
10 A
|
C22.2 No 158
|
300 V
|
10 A
|
UL 1059
|
IEC 60947-7-1:2009
|
EN 60947-7-1:2009
|
DE
|
13.97 g
|
| ||
![]()
ZRKD 2,5/ZBA BU
Art:
3575.5
Copied
|
Blue
|
500 V
|
24 A
|
|
UL, CSA, GL, CSA US, KEMA KUR, EAC
|
|
|
2 x 2
|
2
|
4
|
300 V
|
10 A
|
UL 1059
|
300 V
|
10 A
|
C22.2 No 158
|
300 V
|
10 A
|
UL 1059
|
IEC 60947-7-1:2009
|
EN 60947-7-1:2009
|
DE
|
13.97 g
|
| ||
![]()
ZRKD 2,5/ZBA YE
Art:
3575.8
Copied
|
Yellow
|
500 V
|
24 A
|
|
UL, CSA, GL, CSA US, KEMA KUR, EAC
|
|
|
2 x 2
|
2
|
4
|
300 V
|
10 A
|
UL 1059
|
300 V
|
10 A
|
C22.2 No 158
|
300 V
|
10 A
|
UL 1059
|
IEC 60947-7-1:2009
|
EN 60947-7-1:2009
|
DE
|
13.97 g
|
| ||
![]()
ZRKD 2,5/ZBA RD
Art:
3575.9
Copied
|
Red
|
500 V
|
24 A
|
|
UL, CSA, GL, CSA US, KEMA KUR, EAC
|
|
|
2 x 2
|
2
|
4
|
300 V
|
10 A
|
UL 1059
|
300 V
|
10 A
|
C22.2 No 158
|
300 V
|
10 A
|
UL 1059
|
IEC 60947-7-1:2009
|
EN 60947-7-1:2009
|
DE
|
13.97 g
|
| ||
![]()
ZRKD 2,5/SV/ZBA BG
Art:
3576.2
Copied
|
Beige
|
500 V
|
24 A
|
|
UL, CSA, GL, CSA US, KEMA KUR, EAC
|
|
connected vertically with marking adapter
|
4
|
1
|
4
|
300 V
|
10 A
|
UL 1059
|
300 V
|
10 A
|
C22.2 No 158
|
300 V
|
10 A
|
UL 1059
|
IEC 60947-7-1:2009
|
EN 60947-7-1:2009
|
DE
|
14.87 g
|
| ||
![]()
ZRKD 2,5/SV/ZBA OG
Art:
3576.3
Copied
|
Orange
|
500 V
|
24 A
|
|
UL, CSA, GL, CSA US, KEMA KUR, EAC
|
|
connected vertically with marking adapter
|
4
|
1
|
4
|
300 V
|
10 A
|
UL 1059
|
300 V
|
10 A
|
C22.2 No 158
|
300 V
|
10 A
|
UL 1059
|
IEC 60947-7-1:2009
|
EN 60947-7-1:2009
|
DE
|
14.87 g
|
| ||
![]()
ZRKD 2,5/SV/ZBA BU
Art:
3576.5
Copied
|
Blue
|
500 V
|
24 A
|
|
UL, CSA, GL, CSA US, KEMA KUR, EAC
|
|
connected vertically with marking adapter
|
4
|
1
|
4
|
300 V
|
10 A
|
UL 1059
|
300 V
|
10 A
|
C22.2 No 158
|
300 V
|
10 A
|
UL 1059
|
IEC 60947-7-1:2009
|
EN 60947-7-1:2009
|
DE
|
14.87 g
|
| ||
![]()
ZRKD 2,5/N/DU/ZBA
Art:
3577.2
Copied
|
Beige
|
500 V
|
24 A
|
|
UL, CSA, GL, CSA US, KEMA KUR, EAC
|
|
|
2 x 2
|
1
|
4
|
300 V
|
10 A
|
UL 1059
|
300 V
|
10 A
|
C22.2 No 158
|
300 V
|
10 A
|
UL 1059
|
IEC 60947-7-1:2009
|
EN 60947-7-1:2009
|
DE
|
13.87 g
|
| ||
![]()
ZRKD 2,5/DU/PE/ZBA
Art:
3578.2
Copied
|
Beige
|
500 V
|
24 A
|
|
UL, CSA, GL, CSA US, KEMA KUR, EAC
|
|
|
2 x 2
|
1
|
4
|
300 V
|
10 A
|
UL 1059
|
300 V
|
10 A
|
C22.2 No 158
|
300 V
|
10 A
|
UL 1059
|
IEC 60947-7-1:2009
|
EN 60947-7-1:2009, EN 60947-7-2:2009
|
DE
|
18.47 g
|
| ||
![]()
ZRKD 2,5/N/PE/ZBA
Art:
3579.2
Copied
|
Beige
|
500 V
|
24 A
|
|
UL, CSA, GL, CSA US, KEMA KUR, EAC
|
|
|
2 x 2
|
1
|
4
|
300 V
|
10 A
|
UL 1059
|
300 V
|
10 A
|
C22.2 No 158
|
300 V
|
10 A
|
UL 1059
|
IEC 60947-7-1:2009
|
EN 60947-7-1:2009
|
DE
|
18.47 g
|
| ||
![]()
ZRKD 2,5/LED(RD)/230V AC BG
Art:
3645.2
Copied
|
Beige
|
230 V
|
24 A
|
|
EAC
|
|
with LED status display
|
2 x 2
|
1
|
0
|
|
|
|
|
|
|
|
|
|
|
|
BG
|
13.2 g
|
| ||
![]()
ZRKD 2,5 Ex BG
Art:
1707.2
Copied
|
Beige
|
500 V
|
24 A
|
|
UL, CSA, GL, CSA US, KEMA KUR, EAC
|
Yes
|
|
2 x 2
|
2
|
4
|
300 V
|
10 A
|
UL 1059
|
300 V
|
10 A
|
C22.2 No 158
|
300 V
|
10 A
|
UL 1059
|
IEC 60947-7-1:2009
|
EN 60947-7-1:2009
|
DE
|
12.8 g
|
| ||
![]()
ZRKD 2,5 Ex BU
Art:
1707.5
Copied
|
Blue
|
500 V
|
24 A
|
|
UL, CSA, GL, CSA US, KEMA KUR, EAC
|
Yes
|
|
2 x 2
|
2
|
4
|
300 V
|
10 A
|
UL 1059
|
300 V
|
10 A
|
C22.2 No 158
|
300 V
|
10 A
|
UL 1059
|
IEC 60947-7-1:2009
|
EN 60947-7-1:2009
|
DE
|
12.8 g
|
|
Select a variant in the list