Overview |
|
---|---|
Output current | 25 A |
Output voltage | 24-510V ac |
Control voltage | 4-32V dc |
Mounting | Panel mount |
Type of control | Zero voltage turn on |
Output voltage | 24-510V ac |
Output Specification |
|
Transient Voltage | 1200 V pk |
Maximum off-state leakage current | 1 mA rms |
1 Second surge current | 96 |
Maximum 1 cycle surge current | 320/_ (min) 420 (typ) |
Maximum on-state voltage drop | 1.375 Vpk |
Thermal resistance junction to case | 0.7 °C/W |
Maximum 1/2 Cycle I² t for fusing (A² sec) | 512/880 |
Minimum heat sink for rated current @ 40 °C | 5.2 °C/W |
Number of poles | 3 |
Control voltage | 4-32V dc |
Input Specification |
|
Maximum reverse voltage | -32V dc |
Minimum turn-on voltage | 4V dc |
*Invisible Heading* |
|
---|---|
Must turn-off voltage | 1V dc |
Input current min | 20 mA |
Input Current Max | 25 mA |
Maximum turn-on time (ms) | 1/2 cycle |
Maximum turn-off time (ms) | 1/2 cycle |
General Specification |
|
Dielectric strength input to output (50/60Hz) | 4000 V rms |
Ambient operating temperature | -40 ... +80°C |
Ambient storage temperature | -40 ... +100°C |
Weight | 200 g |
Height | 69.3 mm |
Width | 100 mm |
Depth | 34.7 mm |
Housing material | UL94 V-0 |
Material base | Aluminium |
LED input status indicator | Green |
Approvals | CE, cRUus, UKCA |
This innovative push-in connection system enables time savings of up to 50%, whether you're wiring control panels or managing complex installations
Solar energy has become a pillar of the global energy transition. The experts at OEM Automatic have broken down the role of photovoltaic fuses and their contribution to solar systems, as well as, how to choose the right solution for you.
Ultra fast-acting fuse links engineered specifically to shield delicate semiconductor devices.
Do you need reliable protection for measuring and control equipment? DEHN YellowLine delivers voltage surge protection tailored for building, measuring, and control systems
Choosing the right circuit breaker is important for protecting DC circuits. Two primary forms of protection are MCBs and ECBs. The experts at OEM Automatic breakdown the two circuit breakers for you!
New signal lights from Auer Signal are now available! The first products to be launched in this series are the Smart Dot 50 in the Basic and Standard versions, as well as the Smart Indicator 50 in the Basic version.Â
|
|
|
|
|
||
---|---|---|---|---|---|---|
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
Parts | Output current | Type of control | 1 Second surge current | Maximum 1 cycle surge current | Thermal resistance junction to case | Maximum 1/2 Cycle I² t for fusing (A² sec) | Minimum heat sink for rated current @ 40 °C | Control voltage | Maximum reverse voltage | Minimum turn-on voltage | Must turn-off voltage | Input current min | Input Current Max | Maximum turn-on time (ms) | Maximum turn-off time (ms) | Price | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]()
Art:
GN325DSZH
Copied
|
25 A
|
Zero voltage turn on
|
96
|
320/_ (min) 420 (typ)
|
0.7 °C/W
|
512/880
|
5.2 °C/W
|
4-32V dc
|
-32V dc
|
4V dc
|
1V dc
|
20 mA
|
25 mA
|
1/2 cycle
|
1/2 cycle
|
| ||
![]()
Art:
GN325DSRH
Copied
|
25 A
|
Instantaneous turn on
|
96
|
320/_ (min) 420 (typ)
|
0.7 °C/W
|
512/880
|
5.2 °C/W
|
4-32V dc
|
-32V dc
|
4V dc
|
1V dc
|
20 mA
|
25 mA
|
1/2 cycle
|
1/2 cycle
|
| ||
![]()
Art:
GN325ASZH
Copied
|
25 A
|
Special zero voltage turn on
|
96
|
320/_ (min) 420 (typ)
|
0.7 °C/W
|
512/880
|
5.2 °C/W
|
24-255V ac
|
N/A
|
24V ac
|
2V ac
|
5 mA
|
7 mArms
|
25 ms
|
50 ms
|
| ||
![]()
GN3 3P 50A 24-510Vac out 4-32Vdc in ZC
Art:
GN350DSZH
Copied
|
50 A
|
Zero voltage turn on
|
230
|
700/_ (min) 750 (typ)
|
0.4 °C/W
|
2540/2800
|
1.5 °C/W
|
4-32V dc
|
-32V dc
|
4V dc
|
1V dc
|
20 mA
|
25 mA
|
1/2 cycle
|
1/2 cycle
|
| ||
![]()
Art:
GN350DSRH
Copied
|
50 A
|
Instantaneous turn on
|
230
|
700/_ (min) 750 (typ)
|
0.4 °C/W
|
2540/2800
|
1.5 °C/W
|
4-32V dc
|
-32V dc
|
4V dc
|
1V dc
|
20 mA
|
25 mA
|
1/2 cycle
|
1/2 cycle
|
| ||
![]()
Art:
GN350ASZH
Copied
|
50 A
|
Special zero voltage turn on
|
230
|
700/_ (min) 750 (typ)
|
0.4 °C/W
|
2540/2800
|
1.5 °C/W
|
24-255V ac
|
N/A
|
24V ac
|
2V ac
|
5 mA
|
7 mArms
|
25 ms
|
50 ms
|
|
Select a variant in the list