Overview |
|
---|---|
Output current | 10 A |
Output voltage | 5-200V dc |
Control voltage | 4-32V dc |
Mounting | Panel mount |
Type of control | DC Switching |
Output voltage | 5-200V dc |
Output Specification |
|
Maximum Load Current | 20 A rms |
Minimum Load Current | 5 mA rms |
Transient Voltage | 200 V pk |
Maximum off-state leakage current | 3 mA rms |
Maximum on-state voltage drop | 0.97V pk |
Thermal resistance junction to case | 0,66 °C/W |
Minimum heat sink for rated current @ 40 °C | 3,4 °C/W |
Number of poles | 1 |
Control voltage | 4-32V dc |
Input Specification |
|
Maximum reverse voltage | -32V dc |
Minimum turn-on voltage | 3.5V dc |
*Invisible Heading* |
|
---|---|
Must turn-off voltage | 1V dc |
Input current min | 34 mA |
Input Current Max | 35 mA |
Maximum turn-on time (ms) | 0.02 |
Maximum turn-off time (ms) | 0.02 |
General Specification |
|
Ambient operating temperature | -25 ... +90°C |
Ambient storage temperature | -40 ... +100°C |
Weight | 80 g |
Height | 59,4 mm |
Width | 44,5 mm |
Depth | 29,1 mm |
Housing material | UL94 V-0 |
Material base | Aluminium |
LED input status indicator | Green |
Approvals | CE, cRUus |
Renowned for high-quality cable cutting and crimping tools, Klauke serves electrical contractors, cable jointers, and linemen across a spectrum of sectors
At OEM Automatic, we can supply a series of components for your one project. All under one roof. This case study discusses how we supplied several components for our customer's new electro-pneumatic control box.
To promote constant and reliable performance, as well as a longer life of parts in the vehicle, it is important to consider the right cable protector.
We have now added switch disconnectors to our range! Switch disconnectors contribute to the overall functionality and safety of electrical systems.
LOCC-Box from Lutze is an intelligent current monitoring device that provides reliable protection of DC circuits in a slimline 8.1mm housing.
OEM Automatic has integrated push-in technology into it's product offering for many years now. In this blog post, we'll explore the various benefits of push-in technology and some of the products we offer that make use of this innovation, such as push-in terminals, push-in sockets, and even push-in heaters.
|
|
|
|
|
||
---|---|---|---|---|---|---|
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
Parts | Output current | Output voltage | Maximum Load Current | Transient Voltage | Maximum on-state voltage drop | Thermal resistance junction to case | Minimum heat sink for rated current @ 40 °C | Price | ||
---|---|---|---|---|---|---|---|---|---|---|
SSR 10A 5-200 VDC Out 4-32 VDC In
Art:
84137850N
Copied
|
10 A
|
5-200V dc
|
20 A rms
|
200 V pk
|
0.97V pk
|
0,66 °C/W
|
3,4 °C/W
|
| ||
SSR 40A 5-60 VDC Out 4-32 VDC In
Art:
84137870N
Copied
|
40 A
|
5-60V dc
|
40 A rms
|
100 V pk
|
1.05V pk
|
0,9 °C/W
|
1,15 °C/W
|
|
Select a variant in the list