Overview |
|
---|---|
Output current | 25 A |
Output voltage | 24-280V ac |
Control voltage | 4-32V dc |
Mounting | Panel mount |
Type of control | Zero voltage turn on |
Output voltage | 24-280V ac |
Output Specification |
|
Maximum Load Current | 25 A rms |
Minimum Load Current | 5 mA rms |
Transient Voltage | 600 V pk |
Maximum off-state leakage current | 1 mA rms |
1 Second surge current | 100 |
Maximum 1 cycle surge current | 270/284 (min) 340 (typ) |
Maximum on-state voltage drop | 1.22V |
Thermal resistance junction to case | 1,7 °C/W |
Maximum 1/2 Cycle I² t for fusing (A² sec) | 487 |
Minimum heat sink for rated current @ 40 °C | 1,3 °C/W |
Number of poles | 1 |
Control voltage | 4-32V dc |
Input Specification |
|
Maximum reverse voltage | -32V dc |
*Invisible Heading* |
|
---|---|
Minimum turn-on voltage | 3V dc |
Must turn-off voltage | 1V dc |
Input current min | 10 mA |
Input Current Max | 14 mA |
Maximum turn-on time (ms) | 1/2 Cycle |
Maximum turn-off time (ms) | 1/2 Cycle |
General Specification |
|
Dielectric strength input to output (50/60Hz) | 4000 V rms |
Ambient operating temperature | -40 ... +80°C |
Ambient storage temperature | -40 ... +100°C |
Weight | 80 g |
Height | 59,4 mm |
Width | 44,5 mm |
Depth | 29,1 mm |
Housing material | UL94 V-0 |
Material base | Aluminium |
LED input status indicator | Green |
Approvals | CE, cRUus, VDE |
We shine a spotlight on surge protection devices (SPDs), a crucial yet often overlooked component in industrial settings. Every surge of electricity, every fluctuation in voltage, poses a potential threat to your machinery and systems.
Renowned for high-quality cable cutting and crimping tools, Klauke serves electrical contractors, cable jointers, and linemen across a spectrum of sectors
At OEM Automatic, we can supply a series of components for your one project. All under one roof. This case study discusses how we supplied several components for our customer's new electro-pneumatic control box.
To promote constant and reliable performance, as well as a longer life of parts in the vehicle, it is important to consider the right cable protector.
We have now added switch disconnectors to our range! Switch disconnectors contribute to the overall functionality and safety of electrical systems.
LOCC-Box from Lutze is an intelligent current monitoring device that provides reliable protection of DC circuits in a slimline 8.1mm housing.
|
|
|
|
|
||
---|---|---|---|---|---|---|
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
Parts | Output current | Output voltage | Maximum Load Current | Transient Voltage | 1 Second surge current | Maximum 1 cycle surge current | Maximum on-state voltage drop | Thermal resistance junction to case | Maximum 1/2 Cycle I² t for fusing (A² sec) | Minimum heat sink for rated current @ 40 °C | Minimum turn-on voltage | Must turn-off voltage | Price | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SSR 25A 24-280 VAC Out 4-32 VDC In ZC
Art:
84137910N
Copied
|
25 A
|
24-280V ac
|
25 A rms
|
600 V pk
|
100
|
270/284 (min) 340 (typ)
|
1.22V
|
1,7 °C/W
|
487
|
1,3 °C/W
|
3V dc
|
1V dc
|
| ||
SSR 40A 48-660 VAC Out 4-32 VDC In ZC
Art:
84137450N
Copied
|
40 A
|
48-660V ac
|
40 A rms
|
1200 V pk
|
96
|
320/_ (min) 420 (typ)
|
1.23V
|
0,7 °C/W
|
882
|
1,05 °C/W
|
3.5V dc
|
2V dc
|
| ||
SSR 50A 48-660 VAC Out 4-32 VDC In ZC
Art:
84137460N
Copied
|
50 A
|
48-660V ac
|
50 A rms
|
1200 V pk
|
165
|
530/_ (min) 580 (typ)
|
1.22V
|
0,55 °C/W
|
1680
|
0,85 °C/W
|
3.5V dc
|
2V dc
|
| ||
SSR 90A 48-660 VAC Out 4-32 VDC In ZC
Art:
84137480N
Copied
|
90 A
|
48-660V ac
|
90 A rms
|
1200 V pk
|
347
|
1100/_ (min) 1200 (typ)
|
1.4V
|
0,3 °C/W
|
7200
|
0,33 °C/W
|
3.5V dc
|
2V dc
|
|
Select a variant in the list