• black icon of a bullhorn 30 years industry experience
  • black icon of three cubes Over 8,000 products in stock
  • Black icon of a clock Order by 16:00 and receive the next working day
SENSATA CRYDOM
SENSATA CRYDOM

GNR Series 45mm Relay

  • Load current 35A and 45A
  • Operating Voltage 48-600 VAC
  • Control Voltage 4-32 VDC, 90-140 VAC and 180-260 VAC
  • Broad range of power ratings

Product description

These relays offer a broad range of power ratings which makes them suitable for diverse applications. Their high reliability and efficient design have made of them a market favorite for many years.

  • Current ratings of 35 and 45 amps
  • Output voltage rating: 48-600 VAC
  • Direct Bond Copper (DBC) Substrate
  • LED input status indicator
  • UL 508 Endurance Rating for Enhanced Reliability
  • UL/CSA/TUV Approved, CE Compliant
  • Built-in overvoltage protection
  • DIN Rail or Panel Mount
  • Zero voltage or Instantaneous turn-on output

Technical Data

Output Specifications (1)

Description

GNR35

GNR45

Operating Voltage (47-440Hz) [Vrms]

48-600

48-600

Transient Overvoltage [Vpk, t=1 min.]

1100

1100

Maximum Load Current [Arms]

35

45

Minimum Load Current [Arms]

0.1

0.1

Maximum Off-State Leakage Current @ Rated Voltage [mArms]

0.25

0.25

Static Off-State dv/dt ( V/μsec, Ta=25°C) (2)

500

500

1 Second Surge Current (Apk Ta=25°C) 50/60 Hz

130

150

Forward Voltage Drop (Vpk @ max, Ta=25°C)

1.35

1.35

Maximum Surge Current (50/60 Hz, 1 cycle) [Apk]

668/700

716/750

Maximum I² t for Fusing (50/60Hz, 1/2 cycle ) [A² sec]

2230/2020

2562/2334

HP Ratings at 120V / FLC [Arms]

1.5/20

1.5/20

HP Ratings at 240V / FLC [Arms]

3/17

3/17

HP Ratings at 480V / FLC [Arms]

5/14

5/14

Min/Max stranded wire

16/8 AWG

16/8 AWG

Min/Max solid wire

16/10 AWG

16/10 AWG

 

Input Specifications (1)

Description

GNRxxDx

GNRxxBx

GNRxxAx

Control Voltage Range (3)

4.0-32 VDC

90-140 Vrms

180-280 Vrms

Minimum Turn-On Voltage

4.0 VDC

90 Vrms

180 Vrms

Must Turn-Off Voltage

1.0 VDC

10 Vrms

10 Vrms

Minimum Input Current (for on-state)

16 mA

5 mArms

6 mA

Maximum Input Current

19 mA

6 mArma

8 mA

Input Resistance

Current Regulated

Current Regulated

Current Regulated

Maximum Turn-Off Time [msec]

1/2 Cycle

20

20

Maximum Turn-On Time [msec] (4)

1/2 Cycle

30

30

Min/Max stranded/solid wire

24/16 AWG

24/16 AWG

24/16 AWG

 

General Specifications (1)

Description

Parameters

Ambient Operating Temperature Range (3)

-20 to 80°C

Ambient Storage Temperature Range

-40 to 100°C

Dielectric Strength, Input to Output (50/60Hz)

4000 Vrms

Dielectric Strength, Input/Output to Ground (50/60Hz)

2500 Vrms

Maximum Capacitance, Input/Output

8 pF

Housing Material

UL 94V0 (self extinguishing)

Input Status Indicator

Green LED

Weight (typical)

14.1 oz (400g)

 

General Notes

(1) All parameters at 25°C unless otherwise specified.

(2) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1

(3) For 180-280 VAC Control. Maximum Ambient operating temperatures is 60°C.

(4) Turn-on time for Instantaneous version (R suffix) is 0.1 msec (for DC control only).

(5) TUV Certification according to EN 60950-1/A1:2010

 

Mechanical Specifications (1)

Tolerances: ±0.02 in / 0.5 mm

All dimensions are in: inches [millimeters]

 

Contactor Configuration

Relay Configuration

 

 

Wiring Diagram

 

 

Thermal Derate Information

 

 

 

Agency Approvals

Designed in accordance with the requirements of IEC 62314

cRU UK E79183 SA LR 38595 TDV (5) CE RoSH

 

EMC Compatibility

Designed in accordance with the requirements of IEC 62314

IEC 60068-2-6 35mm/10-55Hz

IEC 62314

IEC 60068-2-27 15G / 11ms

IEC 61000-4-2 Level 3 Electrostatic Discharge

IEC 61000-4-3 Level 3 Radiated Electromagnetic Noise

IEC 61000-4-4 Level 3 Immunity to Electrically Fast Transients

IEC 61000-4-5 Level 3 Immunity to Electrical Surges

IEC 61000-4-6 Level 3 Conducted Electromagnetic Noise

CISPR 11 Class A Conducted and Radiated Noise for Industrial Environments

Part Numbers

Product Selection

Control Voltage

35A

45A

4-32 VDC

GNR35DHZ

GNR45DHZ

90-140 VAC

GNR35BHZ

GNR45BHZ

180-280 VAC

GNR35AHZ

GNR45AHZ

 

Different options available on request.

 

 

Part numbers

Parts Price Output current Type of control Activation Additional features Peak current I2t value Control voltage Turn-off voltage Input current min Input current max Response time Release time
35 A Zero voltage turn on 0 V Relay configuration 130 A 2230 A²s 4-32V dc 1 V 16 mA 19 mA 10 ms 10 ms
35 A Instantaneous turn on Instantaneous Relay configuration 130 A 2230 A²s 4-32V dc 1 V 16 mA 19 mA 10 ms 10 ms
35 A Zero voltage turn on 0 V Contactor configuration 130 A 2230 A²s 4-32V dc 1 V 16 mA 19 mA 10 ms 10 ms
35 A Instantaneous turn on Instantaneous Contactor configuration 130 A 2230 A²s 4-32V dc 1 V 16 mA 19 mA 10 ms 10 ms
35 A Zero voltage turn on 0 V Relay configuration 130 A 2230 A²s 90-140V ac 10 V 5 mA 6 mA 30 ms 20 ms
35 A Zero voltage turn on 0 V Contactor configuration 130 A 2230 A²s 90-140V ac 10 V 5 mA 6 mA 30 ms 20 ms
35 A Zero voltage turn on 0 V Relay configuration 130 A 2230 A²s 180-260V ac 10 V 6 mA 8 mA 30 ms 20 ms
35 A Zero voltage turn on 0 V Contactor configuration 130 A 2230 A²s 180-260V ac 10 V 6 mA 8 mA 30 ms 20 ms
45 A Zero voltage turn on 0 V Relay configuration 150 A 2562 A²s 4-32V dc 1 V 16 mA 19 mA 10 ms 10 ms
45 A Instantaneous turn on Instantaneous Relay configuration 150 A 2562 A²s 4-32V dc 1 V 16 mA 19 mA 10 ms 10 ms
45 A Zero voltage turn on 0 V Contactor configuration 150 A 2562 A²s 4-32V dc 1 V 16 mA 19 mA 10 ms 10 ms
45 A Instantaneous turn on Instantaneous Contactor configuration 150 A 2562 A²s 4-32V dc 1 V 16 mA 19 mA 10 ms 10 ms
45 A Zero voltage turn on 0 V Relay configuration 150 A 2562 A²s 90-140V ac 10 V 5 mA 6 mA 30 ms 20 ms
45 A Zero voltage turn on 0 V Contactor configuration 150 A 2562 A²s 90-140V ac 10 V 5 mA 6 mA 30 ms 20 ms
45 A Zero voltage turn on 0 V Relay configuration 150 A 2562 A²s 180-260V ac 10 V 6 mA 8 mA 30 ms 20 ms
45 A Zero voltage turn on 0 V Contactor configuration 150 A 2562 A²s 180-260V ac 10 V 6 mA 8 mA 30 ms 20 ms

Part

GNR35DHZ
DIN Rail SSR 45mm 600V ac 35A, 4-32V dc In, ZC

Technical data

Overview

Output current 35 A
Output voltage 48-600V ac
Control voltage 4-32V dc
Connection Screw connection
Type of control Zero voltage turn on
Activation 0 V
Additional features Relay configuration

Output Specification

Output voltage 48-600V ac
Leakage current at V max, T=25°C max 1 mA
Peak voltage 1100 V
Peak current 130 A
Voltage drop over semiconductor at max 1,35 V
Number of poles 1
I2t value 2230 A²s

Input Specification

Control voltage 4-32V dc
Turn-off voltage 1 V
Input current min 16 mA
Input current max 19 mA
Response time 10 ms
Release time 10 ms

General Specification

Insulation voltage in/out 4000 V
Temperature operational min -20 °C
Temperature operational max 80 °C
Storage temperature max 100 °C
Storage temperature min -40 °C
Weight 400 g
Height 88,1 mm
Width 45 mm
Depth 120,7 mm
LED indication Input status indication
Approvals CE, CSA, EMC, UL
IP class IP20
Load voltage ac

Measurements and connections

Technical illustrations

Resource

Contact us

If you need any help, you can contact us in one of the following ways:

0116 284 9900

Send an e-mail

Use live chat