Input data |
|
---|---|
Input voltage ac | 100-240 V |
Input voltage ac min | 90 V AC |
Input voltage ac max | 264 V AC |
Input voltage dc | 125-375 V |
Input voltage dc min | 125 V DC |
Input voltage dc max | 375 V DC |
Inrush current at 120 V ac typical | 15 A |
Inrush current at 230 V ac typical | 30 A |
Output data |
|
Output voltage | 24 V DC |
Output voltage min | 24 V DC |
Output voltage max | 24 V DC |
Output current | 0.42 A |
Power | 10 W |
Efficiency / Lifetime / MTBF |
|
Efficiency | 80 % |
Dimensions |
|
Width | 18 mm |
*Invisible Heading* |
|
---|---|
Height | 91 mm |
Depth | 55.6 mm |
Weight | 0.065 kg |
Other |
|
Approvals | CB, CE, NEC Class 2, TÜV, UL |
Hold time at 120 V ac, typical full load | 10 ms |
Hold time at 230 V ac, typical full load | 60 ms |
IP class | IP20 |
Clamp type | Screw |
Material protection | Plastic |
Supply frequency | 50-60 Hz |
Power consumption 120 V ac | 0.3 A |
Power consumption 230 V ac | 0.2 A |
Temperature min without derating | -25 °C |
Temperature max without derating | 55 °C |
What tri-rated cable are you currently using? Does the product or service you receive leave you wanting more? It’s time to ask the question. Because now, you’ve got options.
This innovative push-in connection system enables time savings of up to 50%, whether you're wiring control panels or managing complex installations
Solar energy has become a pillar of the global energy transition. The experts at OEM Automatic have broken down the role of photovoltaic fuses and their contribution to solar systems, as well as, how to choose the right solution for you.
Ultra fast-acting fuse links engineered specifically to shield delicate semiconductor devices.
Do you need reliable protection for measuring and control equipment? DEHN YellowLine delivers voltage surge protection tailored for building, measuring, and control systems
Choosing the right circuit breaker is important for protecting DC circuits. Two primary forms of protection are MCBs and ECBs. The experts at OEM Automatic breakdown the two circuit breakers for you!
|
|
|
|
|
||
---|---|---|---|---|---|---|
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
Parts | Inrush current at 120 V ac typical | Inrush current at 230 V ac typical | Output voltage min | Output voltage max | Output current | Power | Efficiency | Width | Weight | Hold time at 120 V ac, typical full load | Power consumption 120 V ac | Power consumption 230 V ac | Price | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]()
Power Supply Chrome 24VDC 10W 0.42A
Art:
DRC-24V10W1AZ
Copied
|
15 A
|
30 A
|
24 V DC
|
24 V DC
|
0.42 A
|
10 W
|
80 %
|
18 mm
|
0.065 kg
|
10 ms
|
0.3 A
|
0.2 A
|
| ||
![]()
Art:
DRC-24V10W1HZ
Copied
|
15 A
|
30 A
|
24 V DC
|
24 V DC
|
0.42 A
|
10 W
|
80 %
|
18 mm
|
0.065 kg
|
10 ms
|
0.3 A
|
0.2 A
|
| ||
![]()
Art:
DRC-24V30W1AZ
Copied
|
25 A
|
50 A
|
23.52 V DC
|
24.48 V DC
|
1.25 A
|
30 W
|
87 %
|
53 mm
|
0.14 kg
|
25 ms
|
0.8 A
|
0.6 A
|
| ||
![]()
Power Supply Chrome 24VDC 60W 2.5A
Art:
DRC-24V60W1AZ
Copied
|
30 A
|
60 A
|
24 V DC
|
28 V DC
|
2.5 A
|
60 W
|
88 %
|
71 mm
|
0.22 kg
|
16 ms
|
1.5 A
|
1 A
|
| ||
![]()
Art:
DRC-24V100W1AZ
Copied
|
30 A
|
60 A
|
22 V DC
|
24 V DC
|
3.8 A
|
91.2 W
|
89 %
|
89.9 mm
|
0.35 kg
|
10 ms
|
2.2 A
|
1 A
|
|
Select a variant in the list