PULS
Puls Dimension Q is a series of power supplies with very small construction dimensions and many technical advantages.
The unit has low inrush current (even during warm start), active PFC, which provides a power factor close to one, extended temperature range, as well as active protection against mains transients. Furthermore, there is a relay output (DC OK) that falls when the output voltage deviates more than 10% from the set value.
The bonus power provides 50% extra reserve with retained voltage which is an advantage when connected loads have high starting currents. The unit also provides a high short-circuit current that simplifies tripping of secondary fuses. Both the bonus power and short-circuit current is limited to 4 seconds to avoid constant overloading of the power supply and wiring.
High efficiency for long life and low temperature. The power supply can be connected for two-phase operation Within up to +40°C. At higher temperatures, the load current is reduced.
We recommend clearance of 40 mm and 20 mm below the unit and 5 mm on the sides. (15 mm on the sides if adjacent products are a heat source).
Bonus power
The power supply has a bonus power that enables high power output with maintained 48 V dc for 4 seconds, which is a big advantage when connected loads have high starting current, e.g. motors. How often you can use the bonus power depends on the application. With the diagram and formula below you can calculate the available repeat time for each application. Bonus power is available as soon as the power supply starts and immediately after a short circuit
Bonus power | Operating cycle | ||
Po | Nominal load current | ||
Ppeak | Peak current | ||
To | Time between bonus power | ||
Tpeak | Peak current I time | ||
Operating cycle | Tpeak/ (Tpeak+To) | ||
To | Tpeak- (operating cycle*Tpeak) / operating cycle | ||
E.g. 48 V DC power supply Nominal load current (Po) is 7.5 A. Peak current (Ppeak) is 12A=120 %. Peak time is 3 seconds. 7.5 A=75 % of Inom. According to the diagram the operating cycle is 50%. To= 3- (0.5*3) / 0.5=3. Maximum repeat time of the bonus power is 3 seconds. |
Input data |
|
---|---|
Input voltage ac | 380-480 V |
Input voltage ac min | 323 V AC |
Input voltage ac max | 552 V AC |
Inrush current at 400 V ac typical | 3 A |
Input voltage range | Wide-range |
Power factor at 400 V ac, full load. Typical | 0,94 |
Number of phases | 3 |
Output data |
|
Output voltage | 48 V DC |
Output voltage min | 48 V DC |
Output voltage max | 55 V DC |
Output current | 10 A |
Power | 480 W |
Efficiency / Lifetime / MTBF |
|
Efficiency at 400 V ac, typical | 94,4 % |
Efficiency at 400 V ac, full load, typical | 95,4 % |
Lifetime at 400 V ac, full load and +40 ° C | 51000 h |
MTBF (IEC 61709) 400 V ac, max loan, +40 °C | 690000 h |
Dimensions |
|
Width | 65 mm |
Height | 124 mm |
*Invisible Heading* |
|
---|---|
Depth | 127 mm |
Weight | 0,87 kg |
Other |
|
Approvals | CB, CE, CSA US, cRUus, cULus, GL |
Hold time at 400 V ac, typical full load | 22 ms |
IP class | IP20 |
Clamp type | Spring-clamp |
Material protection | Aluminium |
Supply frequency | 50-60 ±6 % |
Ripple max | 100 mV pp |
Series | Dimension Q |
Power consumption at 400 V ac | 0,79 A |
Power drop from +60 °C to + 70 °C | 12 W/°C |
Temperature min without derating | -25 °C |
Temperature max without derating | 60 °C |
Type Power Supply | AC-DC |
DC relay output | Yes |
Active Transient | Yes |
Puls Dimension Q is a series of power supplies with very small construction dimensions and many technical advantages.
The unit has low inrush current (even during warm start), active PFC, which provides a power factor close to one, extended temperature range, as well as active protection against mains transients. Furthermore, there is a relay output (DC OK) that falls when the output voltage deviates more than 10% from the set value.
The bonus power provides 50% extra reserve with retained voltage which is an advantage when connected loads have high starting currents. The unit also provides a high short-circuit current that simplifies tripping of secondary fuses. Both the bonus power and short-circuit current is limited to 4 seconds to avoid constant overloading of the power supply and wiring.
High efficiency for long life and low temperature. The power supply can be connected for two-phase operation Within up to +40°C. At higher temperatures, the load current is reduced.
We recommend clearance of 40 mm and 20 mm below the unit and 5 mm on the sides. (15 mm on the sides if adjacent products are a heat source).
Bonus power
The power supply has a bonus power that enables high power output with maintained 48 V dc for 4 seconds, which is a big advantage when connected loads have high starting current, e.g. motors. How often you can use the bonus power depends on the application. With the diagram and formula below you can calculate the available repeat time for each application. Bonus power is available as soon as the power supply starts and immediately after a short circuit
Bonus power | Operating cycle | ||
Po | Nominal load current | ||
Ppeak | Peak current | ||
To | Time between bonus power | ||
Tpeak | Peak current I time | ||
Operating cycle | Tpeak/ (Tpeak+To) | ||
To | Tpeak- (operating cycle*Tpeak) / operating cycle | ||
E.g. 48 V DC power supply Nominal load current (Po) is 7.5 A. Peak current (Ppeak) is 12A=120 %. Peak time is 3 seconds. 7.5 A=75 % of Inom. According to the diagram the operating cycle is 50%. To= 3- (0.5*3) / 0.5=3. Maximum repeat time of the bonus power is 3 seconds. |
To help experience the capabilities of Z+F machines first-hand, we provide an in-depth demonstration and workshop. These sessions will show the machines in action and allow you to understand their features and gain valuable insight into their operation and benefits.
We are thrilled to announce the launch of IATECH, THe Industrial Automation Technology expo at Leicester Marriott Hotel on 23rd October. The ultimate platform for showcasing our extensive product range and broad business areas, featuring over 50 leading suppliers under one roof!
The specialist vehicle industry can include automotive and EV, heavy vehicles such as agriculture and rail, and marine. This email takes you through some of the various products we offer for specialist vehicle applications.
This blog post delves into the key components, current trends, and best practices in power distribution, illustrating the significant impact these systems have on our daily operations and long-term energy strategies.
We shine a spotlight on surge protection devices (SPDs), a crucial yet often overlooked component in industrial settings. Every surge of electricity, every fluctuation in voltage, poses a potential threat to your machinery and systems.
Renowned for high-quality cable cutting and crimping tools, Klauke serves electrical contractors, cable jointers, and linemen across a spectrum of sectors
|
|
|
|
|
||
---|---|---|---|---|---|---|
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
Parts | Price | ||
---|---|---|---|
PSU 3PH 380-480V ac I/P 48V dc 10A 480W O/P
Art:
QT20.481
Copied
|
|
Select a variant in the list
If you need any help, you can contact us in one of the following ways: