PULS
Puls Dimension C is an affordable range of very high quality, reliability and performance.
CT5 has integrated primary fuses that make it possible to connect the unit without the need for intermediate fuses up to 32 A (UL) which saves space and money.
The efficiency is high over a wide load range, which results in reduced power consumption and longer life regardless of load current. The average efficiency is 88.8% with a peak value of 90.4%.
The power supply can provide a higher short-circuit current for a short time, which helps to secondary fuses. Power boost of 20% enables higher current extraction without voltage drops. This is especially useful during start-ups and to bridge the current peaks in the application. The power reserve can be used continuously up to + 45°C and short periods from +45 to +60°C.
Active transient ensure operation also in very störrik electrical environment and moreover CT5 has active inrush current protection, which means a very low starting current, even if the unit has been in operation for a longer time. This is particularly useful for redundant / parallel system.
Power supply is connected to two phases, saving wiring and fuses. Thanks to the low power consumption, the effect of the imbalance in the three-phase system is negligible.
We recommend free space of 40 mm above and 20 mm below the unit and 5 mm on the sides.
Input data |
|
---|---|
Input voltage ac | 380-480 V |
Input voltage ac min | 323 V AC |
Input voltage ac max | 576 V AC |
Inrush current at 400 V ac typical | 4 A |
Input voltage range | Wide-range |
Power factor at 400 V ac, full load. Typical | 0,45 |
Number of phases | 2 |
Output data |
|
Output voltage | 24 V DC |
Output voltage min | 24 V DC |
Output voltage max | 28 V DC |
Output current | 5 A |
Power | 120 W |
Efficiency / Lifetime / MTBF |
|
Efficiency at 400 V ac, typical | 88,8 % |
Efficiency at 400 V ac, full load, typical | 90,4 % |
Lifetime at 400 V ac, full load and +40 ° C | 92000 h |
MTBF (IEC 61709) 400 V ac, max loan, +40 °C | 1173000 h |
Dimensions |
|
Width | 40 mm |
Height | 124 mm |
*Invisible Heading* |
|
---|---|
Depth | 117 mm |
Weight | 0,5 kg |
Other |
|
Approvals | ABS, CB, CE, CSA US, cRUus, cULus, GL |
Hold time at 400 V ac, typical full load | 27 ms |
IP class | IP20 |
Clamp type | Screw |
Material protection | Aluminium |
Supply frequency | 50-60 ±6 % |
Ripple max | 50 mV pp |
Series | Dimension C |
Power consumption at 400 V ac | 0,75 A |
Power drop from +60 °C to + 70 °C | 3 W/°C |
Temperature min without derating | -25 °C |
Temperature max without derating | 60 °C |
Type Power Supply | AC-DC |
Active Transient | Yes |
Puls Dimension C is an affordable range of very high quality, reliability and performance.
CT5 has integrated primary fuses that make it possible to connect the unit without the need for intermediate fuses up to 32 A (UL) which saves space and money.
The efficiency is high over a wide load range, which results in reduced power consumption and longer life regardless of load current. The average efficiency is 88.8% with a peak value of 90.4%.
The power supply can provide a higher short-circuit current for a short time, which helps to secondary fuses. Power boost of 20% enables higher current extraction without voltage drops. This is especially useful during start-ups and to bridge the current peaks in the application. The power reserve can be used continuously up to + 45°C and short periods from +45 to +60°C.
Active transient ensure operation also in very störrik electrical environment and moreover CT5 has active inrush current protection, which means a very low starting current, even if the unit has been in operation for a longer time. This is particularly useful for redundant / parallel system.
Power supply is connected to two phases, saving wiring and fuses. Thanks to the low power consumption, the effect of the imbalance in the three-phase system is negligible.
We recommend free space of 40 mm above and 20 mm below the unit and 5 mm on the sides.
If you need any help, you can contact us in one of the following ways: