PULS

Power supply 1-phase, 12 V dc Dimension C Series

Puls Dimension C-series stands for cost optimization without compromising quality, reliability or performance. CPS20.121 high efficiency over a wide load range, which results in reduced power consumption and longer life regardless of load current. An average efficiency is 91.6% with a peak value of 92.6%. In addition, power losses very low at idle, only 3 W at 230 V ac.

 

Short-circuit currents. CPS20 can leave short-circuit currents which is 4 times the nominal current for 15 ms, which helps secondary fuses and achieve selectivity.

 

Hiccup Plus.

With new pulse short circuit protection you get optimum protection. The unit leaves a very high short circuit that solves fuses and provides sufficient starting current for example DC motors. If the output voltage falls below 6 V dc is 2x the rated power is left for 2 seconds, then close the unit by the end to make a new restart attempts after about 18 seconds. This feature ensures a high short-circuit/overload current while avoiding a constant high current that can lead to heat and component damage.

 

Technical advantages. CPS20 has active power factor correction (PFC) and actively current inrush protection that effectively reduces start currents which are ideal if several units are connected in the same phase or if the supply is current limited through example. AC UPS. The protection is always active, regardless of the temperature. DC-OK output, wide temperature range, a large number of approvals and transient filter which ensures operation in interference prone electrical environment makes the unit suitable for virtually all installations.

 

For a good cooling, we recommend a clearance of 40 mm over 20 mm below and 5 mm on the sides. (15 mm on the sides of adjacent product is a heat source, such as another power supply.)

 

Stripping sec. fuses

 

0,75 mm2

1,0 mm2

1,5 mm2

2,5 mm2

C-3A

9 m

12 m

18 m

26 m

C-4A

7 m

10 m

14 m

22 m

C-6A

4 m

6 m

10 m

14 m

C-8A

3 m

5 m

8 m

12 m

C-10A

3 m

4 m

7 m

10 m

B-6A

8 m

11 m

14 m

24 m

B-10A

5 m

7 m

10 m

17 m

B-13A

4 m

6 m

9 m

14 m

B-16A

3 m

5 m

7 m

11 m

 

 

 

Read more
  • Output current 30 A
  • Up to 92.5% efficiency
  • 65 mm wide
  • Active PFC
  • Hiccup Plus

Selected variant

Selected variant

Technical data

Input data

Input voltage ac 100-240 V
Input voltage ac min 85 V AC
Input voltage ac max 264 V AC
Inrush current at 120 V ac typical 9 A
Inrush current at 230 V ac typical 7 A
Input voltage range Wide-range
Power factor at 120 V ac, full load. Typical 0,99
Power factor at 230 V ac, full load. Typical 0,95
Number of phases 1

Output data

Output voltage 12 V DC
Output voltage min 12 V DC
Output voltage max 15 V DC
Output current 30 A
Power 360 W

Efficiency / Lifetime / MTBF

Efficiency at 120 V ac, full load, typical 91,4 %
Efficiency at 230 V ac, typical 91,6 %
Efficiency at 230 V ac, full load, typical 92,6 %
Lifetime at 120 V ac, full load and +40 ° C 50000 h
Lifetime at 230 V ac, full load and +40 ° C 54000 h
MTBF (IEC 61709) 230 V ac, max load, 40 ° C 554000 h

Dimensions

Width 65 mm

*Invisible Heading*

Height 124 mm
Depth 127 mm
Weight 1 kg

Other

Approvals ABS, ATEX, CB, CE, CSA US, cRUus, cULus, GL, IECEx
Hold time at 120 V ac, typical full load 35 ms
Hold time at 230 V ac, typical full load 35 ms
IP class IP20
Clamp type Screw
Material protection Aluminium
Supply frequency 50-60 ±6 %
Ripple max 100 mV pp
Series Dimension C
Power consumption 120 V ac 3,3 A
Power consumption 230 V ac 1,8 A
Power drop from +60 °C to + 70 °C 0,75 W/°C
Temperature min without derating -25 °C
Temperature max without derating 60 °C
Type Power Supply AC-DC
DC relay output Yes
Active Transient Yes

Product description

Puls Dimension C-series stands for cost optimization without compromising quality, reliability or performance. CPS20.121 high efficiency over a wide load range, which results in reduced power consumption and longer life regardless of load current. An average efficiency is 91.6% with a peak value of 92.6%. In addition, power losses very low at idle, only 3 W at 230 V ac.

 

Short-circuit currents. CPS20 can leave short-circuit currents which is 4 times the nominal current for 15 ms, which helps secondary fuses and achieve selectivity.

 

Hiccup Plus.

With new pulse short circuit protection you get optimum protection. The unit leaves a very high short circuit that solves fuses and provides sufficient starting current for example DC motors. If the output voltage falls below 6 V dc is 2x the rated power is left for 2 seconds, then close the unit by the end to make a new restart attempts after about 18 seconds. This feature ensures a high short-circuit/overload current while avoiding a constant high current that can lead to heat and component damage.

 

Technical advantages. CPS20 has active power factor correction (PFC) and actively current inrush protection that effectively reduces start currents which are ideal if several units are connected in the same phase or if the supply is current limited through example. AC UPS. The protection is always active, regardless of the temperature. DC-OK output, wide temperature range, a large number of approvals and transient filter which ensures operation in interference prone electrical environment makes the unit suitable for virtually all installations.

 

For a good cooling, we recommend a clearance of 40 mm over 20 mm below and 5 mm on the sides. (15 mm on the sides of adjacent product is a heat source, such as another power supply.)

 

Stripping sec. fuses

 

0,75 mm2

1,0 mm2

1,5 mm2

2,5 mm2

C-3A

9 m

12 m

18 m

26 m

C-4A

7 m

10 m

14 m

22 m

C-6A

4 m

6 m

10 m

14 m

C-8A

3 m

5 m

8 m

12 m

C-10A

3 m

4 m

7 m

10 m

B-6A

8 m

11 m

14 m

24 m

B-10A

5 m

7 m

10 m

17 m

B-13A

4 m

6 m

9 m

14 m

B-16A

3 m

5 m

7 m

11 m

 

 

 

Accessories

Related products

Related

Parts Price

Selected variant

Select a variant in the list

Contact us

If you need any help, you can contact us in one of the following ways:

phone 0116 284 9900

Send an e-mail Send an e-mail

comments Use live chat