4 POLE DISTRIBUTION BLOCKS

RPQ

  • 40 A to 160 A
  • Brass conductors
  • Self-extinguishing insulating structure UL 94-V0
  • Insulation between phases

Product description

The 4 pole disttribution blocks are brass conductors which have galvanized steel screws included this enables insulation between phases.

 

Each block has a front removable protection screen. Wtih self-extinguishing insulating structure :

 

 UL 94-V0 approved

 

Quick hook-up on DIN rails.

 

Compliant with standards IEC 947-7-1.

 

Advantages

  • Separate inputs
  • Forged conductors
  • Easy wiring: RPQ1015, RPQ1018
  • Modular depth: RPQ1016, RPQ1017
Eplan Logo, data portal for 3D drawings

Part numbers

Parts Price Connections Number of inputs A Input A: diameter Input A: wire cross-section stranded, min. Input A: wire cross-section stranded, max. Input A: wire cross-section with wire-end ferrules, min. Input A: wire cross-section with wire-end ferrules, max. Input A: torque, min. Input A: torque, max. Number of outputs A Output A: wire cross-section stranded with wire-end ferrules, max. Number of outputs B Fix. Hole space Length (L) Height (H) Width (P) Width (I)
12 1 11,5 mm 10 mm² 50 mm² 10 mm² 50 mm² 8 Nm 10 Nm 3 25 mm² 8 150 mm 168 mm 85 mm 70 mm
12 1 11,5 mm 10 mm² 50 mm² 10 mm² 50 mm² 8 Nm 10 Nm 3 16 mm² 8 163 mm 176 mm 105 mm 55 mm
12 1 11,5 mm 10 mm² 50 mm² 10 mm² 50 mm² 8 Nm 10 Nm 3 16 mm² 8 163 mm 176 mm 105 mm 55 mm
12 1 12 mm 10 mm² 50 mm² 10 mm² 50 mm² 8 Nm 10 Nm 3 25 mm² 8 135 mm 154 mm 95 mm 67 mm
14 4 16 mm² 10 161 mm 27 mm 17 mm 57 mm

Part

RPQ1015
4 pole Distribution Block 160 A - RPQ 160-11

Technical data

General Data

Rated current 160 A
IP class IP20
Nominal insulation voltage 600 V
Short-circuit current resistance IPK (peak value) 22 kA
Short-circuit current resistance ICW over 1s 9 kA

Connection Data

Connections 12
Number of inputs A 1
Input A: diameter 11,5 mm
Input A: wire cross-section stranded, min. 10 mm²
Input A: wire cross-section stranded, max. 50 mm²
Input A: wire cross-section with wire-end ferrules, min. 10 mm²
Input A: wire cross-section with wire-end ferrules, max. 50 mm²
Input A: torque, min. 8 Nm
Input A: torque, max. 10 Nm
Number of outputs A 3
Output A: diameter 8,5 mm
Output A: wire cross-section stranded, min. 10 mm²
Output A: wire cross-section stranded, max. 35 mm²
Output A: wire cross-section stranded with wire-end ferrules, min. 10 mm²
Output A: wire cross-section stranded with wire-end ferrules, max. 25 mm²
Output A: torque, min. 2 Nm
Output A: torque, max. 3 Nm
Number of outputs B 8
Output B: diameter 7 mm
Output B: wire cross-section stranded, min. 2,5 mm²
Output B: wire cross-section stranded, max. 16 mm²
Output B: wire cross-section stranded with wire-end ferrules, min. 1,5 mm²
Output B: wire cross-section stranded with wire-end ferrules, max. 16 mm²
Output B: torque, min. 2 Nm
Output B: torque, max. 3 Nm
Screw type Galvanized steel screws

Dimensions

Fix. Hole space 150 mm
Length (L) 168 mm
Height (H) 85 mm
Width (P) 70 mm

Additional Data

Pack size 1

Resource