CROUZET CONTROL

Crouzet - 3 phase, phase control MWG

Control relay for phase monitoring with voltage regeneration (returned voltage) up to 70 % of the measurement voltage. Adjustable switch at the front for adjustment of correct voltage in 3-phase networks. The switch's position is not registered until the operating voltage is switched on. If the switch position is changed during operation, all LEDs (LED indication) begin to flash but the unit will continue to function normally with the voltage that was set at the most recent power connection. The relay monitors the correct phase sequence between the three phases or if any phase is lacking (measured U<0.7xUn), 70 % of the returned voltage. If the operating voltage is switched on with a measured fault, the relay remains deactivated. Green LED (Un) indicates supply voltage OK. Yellow LED (R) indicates active relay output.

Read more
  • Triggers alarm when phase sequence or phase interruption faults occurs
  • Adjustable line voltage
  • Measures returned voltage to 70 %
  • 17.5 mm cabinet with DIN rail

Selected variant

Selected variant

Technical data

Approvals CSA, GL, RoHS, UL
Breaking capacity 5A, 250V AC/DC
Function Phase Sequence, Phase Failure
IP class connection IP20
IP class housing IP30
Mounting 35 mm DIN-Rail
Output Relay
Selection of rated voltage 208, 220, 380, 400, 415, 440, 480 V
Storage temperature max 70 °C
Storage temperature min -40 °C
Supply voltage 3 x 208-480V AC
Temperature operational max 50 °C
Temperature operational min -20 °C
Time delay startup 0,5 s
Time delay when exceeding the limit value 0,2 s
Weight 80 g

Measurements and connections

Control relay dimensions

Wiring

F1: Fast-blow fuse 100 mA (recommendation)

Technical illustrations

Phase interruption and phase sequence

1: L1
2: L2
3: L3
4: Relay

Product description

Control relay for phase monitoring with voltage regeneration (returned voltage) up to 70 % of the measurement voltage. Adjustable switch at the front for adjustment of correct voltage in 3-phase networks. The switch's position is not registered until the operating voltage is switched on. If the switch position is changed during operation, all LEDs (LED indication) begin to flash but the unit will continue to function normally with the voltage that was set at the most recent power connection. The relay monitors the correct phase sequence between the three phases or if any phase is lacking (measured U<0.7xUn), 70 % of the returned voltage. If the operating voltage is switched on with a measured fault, the relay remains deactivated. Green LED (Un) indicates supply voltage OK. Yellow LED (R) indicates active relay output.

Accessories

Related

Parts Price

Selected variant

Select a variant in the list

Contact us

If you need any help, you can contact us in one of the following ways:

phone 0116 284 9900

Send an e-mail Send an e-mail

comments Use live chat