• black icon of a bullhorn 30 years industry experience
  • black icon of three cubes Over 8,000 products in stock
  • Black icon of a clock Order by 16:00 and receive the next working day
CROUZET AUTOMATION
CROUZET AUTOMATION

Millenium 3 Essential

  • Green screen display
  • Digital and analogue inputs
  • Multi control voltages (dc only)
  • Expandable to up to 50 I/O

Product description

Millenium 3 is a compact control unit with powerful functions that provides the capability to build both simple and more complex control and monitoring functions. A few examples of fields of application are air conditioning and heating systems, authorisation controls, vending machines, packaging, pump control and advertising signs. Millenium 3 has the most extensive function library on the market and can even be programmed in Ladder. Function block examples: Time functions, counters, connection timers, mathematical blocks or blocks for analogue signals, logic functions, control of motors, pump control and PID regulation. Millenium 3 also includes “SFC blocks”, which are very useful for sequence programming.

Part numbers

Parts Price Number of inputs Number of outputs Supply voltage Expandable Display Program size Measurement range analog inputs Logic 1 voltage threshold (DC input) Logic 0 voltage threshold (DC input) Output type Switching voltage max Width
8 4 12 V DC False Yes FBD 180 blocks, Ladder 120 rows normally 0-10 V DC, 0-12 V DC 7 V 3 V Relay 250 V AC 71,2 mm
8 4 24 V DC False No FBD 180 blocks, Ladder 120 rows normally 0-10 V DC, 0-24 V DC 15 V 5 V Relay 250 V AC 71,2 mm
8 4 24 V DC False Yes FBD 180 blocks, Ladder 120 rows normally 0-10 V DC, 0-24 V DC 15 V 5 V Relay 250 V AC 71,2 mm
8 4 24 V DC False Yes FBD 180 blocks, Ladder 120 rows normally 0-10 V DC, 0-24 V DC 15 V 5 V Solid state (including 1 PWM) 71,2 mm
12 8 12 V DC False Yes FBD 180 blocks, Ladder 120 rows normally 0-10 V DC, 0-12 V DC 7 V 3 V Relay 250 V AC 124,6 mm
12 8 24 V DC False No FBD 180 blocks, Ladder 120 rows normally 0-10 V DC, 0-24 V DC 15 V 5 V Relay 250 V AC 124,6 mm
12 8 24 V DC False Yes FBD 180 blocks, Ladder 120 rows normally 0-10 V DC, 0-24 V DC 15 V 5 V Relay 250 V AC 124,6 mm
12 8 24 V DC False Yes FBD 180 blocks, Ladder 120 rows normally 0-10 V DC, 0-24 V DC 15 V 5 V Solid State (including 4 PWM) 124,6 mm
6 4 24 V DC True Yes FBD 350 blocks, Ladder 120 rows normally 0-10 V DC, 0-24 V DC 15 V 5 V Relay 250 V AC 71,2 mm
6 4 24 V DC True Yes FBD 350 blocks, Ladder 120 rows normally 0-10 V DC, 0-24 V DC 15 V 5 V Solid state (including 1 PWM) 71,2 mm
16 10 12 V DC True Yes FBD 350 blocks, Ladder 120 rows normally 0-10 V DC, 0-12 V DC 7 V 3 V Relay 250 V AC 124,6 mm
16 10 24 V DC True Yes FBD 350 blocks, Ladder 120 rows normally 0-10 V DC, 0-24 V DC 15 V 5 V Relay 250 V AC 124,6 mm
16 10 24 V DC True Yes FBD 350 blocks, Ladder 120 rows normally 0-10 V DC, 0-24 V DC 15 V 5 V Solid State (including 4 PWM) 124,6 mm
16 10 24 V DC True No FBD 350 blocks, Ladder 120 rows normally 0-10 V DC, 0-24 V DC 15 V 5 V Relay 250 V AC 124,6 mm
16 10 24 V DC True No FBD 350 blocks, Ladder 120 rows normally 0-10 V DC, 0-24 V DC 15 V 5 V Solid State (including 4 PWM) 124,6 mm
16 10 12 V DC True No FBD 350 blocks, Ladder 120 rows normally 0-10 V DC, 0-12 V DC 7 V 3 V Relay 250 V AC 124,6 mm
16 10 12 V DC True Yes FBD 350 blocks, Ladder 120 rows normally 0-10 V DC, 0-12 V DC 7 V 3 V Solid State (including 4 PWM) 124,6 mm
6 4 24 V DC True No FBD 350 blocks, Ladder 120 rows normally 0-10 V DC, 0-24 V DC 15 V 5 V Relay 250 V AC 71,2 mm

Part

88970045
Millenium 3 CD12 8 In 4 Out Relay 12V dc

Technical data

General data

Number of inputs 8
Number of outputs 4
Supply voltage 12 V DC
Expandable False
Display Yes
Immunity from micro power cuts 1 ms
Memory for data 368 bits / 200 words, stored for 10 years
Programming method Functionblocks / SFC or Ladder
Program memory Flash EEPROM
Program size FBD 180 blocks, Ladder 120 rows normally
Real time clock True
Measurement range analog inputs 0-10 V DC, 0-12 V DC
Logic 1 voltage threshold (DC input) 7 V
Logic 0 voltage threshold (DC input) 3 V
Release time 5 ms
Output type Relay
Switching voltage max 250 V AC
Load current min 10 mA
Mechanical life expectancy 10 Million operations

Other technical data

Width 71,2 mm
Depth 59,5 mm
Height 90 mm
Temperature operational min -20 °C
Temperature operational max 70 °C
Approvals CE, CSA, RoHS, UL