CROUZET AUTOMATION
Save time in designing your application and remote functions using the most intuitive graphical function block language in the market.
Â
em4 offers the ability to control and monitor equipment more advanced than Millenium 3.
Â
em4 features up to 4 high speed counting inputs and can handle 0-10V and 4-20mA inputs.
Â
em4 has 16 inputs and 10 outputs in the basic version. Up to two expansion modules can be connected to increase the I/O count up to 46.
Â
em4 Alert
Can send alarms and logged data via SMS and email. Information can be exchanged between several em4 Alert controllers. Communication via 3g network using and SIM card.
Â
em4 Local
Available in two versions - standalone and with built-in modbus TCP/IP for local communications.
Â
Crouzet Soft
Controller is programmed with function block diagram (FBD) using a PC with free software. The software features function blocks to send alarms and log files making programming easy and intuitive.
Â

General data |
|
|---|---|
| Number of inputs | 16 |
| Number of outputs | 10 |
| Supply voltage | 24 V DC |
| Expandable | Yes |
| Display | Yes |
| Memory for data | 2 k octets |
| Programming method | Function block / SFC |
| Program memory | Flash |
| Program size | FBD typically 1000 blocks |
| Real time clock | Yes |
| Count speed | Up to 60 kHz |
| Input type | 16 digital (8 analog) |
| Measurement range analog inputs | 0-10 V DC, 0-24 V DC, 0-20mA |
*Invisible Heading* |
|
|---|---|
| Logic 1 voltage threshold (DC input) | 15 V |
| Logic 0 voltage threshold (DC input) | 9 V |
| Output type | 2 SSR / PWM, 8 relays |
| Static / PWM output | Outputs O1 & O2 |
| Pulse duty factor PWM | O1-O2: PWM 0-100% 100 Step, 14-1758 Hz |
| Switching voltage max | 250 V AC |
Other technical data |
|
| Width | 124.6 mm |
| Depth | 60.6 mm |
| Height | 90 mm |
| Temperature operational min | -20 °C |
| Temperature operational max | 60 °C |
| Approvals | CE, cULus |
Save time in designing your application and remote functions using the most intuitive graphical function block language in the market.
Â
em4 offers the ability to control and monitor equipment more advanced than Millenium 3.
Â
em4 features up to 4 high speed counting inputs and can handle 0-10V and 4-20mA inputs.
Â
em4 has 16 inputs and 10 outputs in the basic version. Up to two expansion modules can be connected to increase the I/O count up to 46.
Â
em4 Alert
Can send alarms and logged data via SMS and email. Information can be exchanged between several em4 Alert controllers. Communication via 3g network using and SIM card.
Â
em4 Local
Available in two versions - standalone and with built-in modbus TCP/IP for local communications.
Â
Crouzet Soft
Controller is programmed with function block diagram (FBD) using a PC with free software. The software features function blocks to send alarms and log files making programming easy and intuitive.
Â

|
|
|
|
|
|
||
|---|---|---|---|---|---|---|
|
|
|
|
|
|
||
|
|
|
|
|
|
||
|
|
|
|
|
|
||
|
|
|
|
|
|
||
|
|
|
|
|
|
||
|
|
|
|
|
|
| Parts | Number of inputs | Number of outputs | Display | Memory for data | Programming method | Program memory | Program size | Real time clock | Count speed | Input type | Measurement range analog inputs | Logic 1 voltage threshold (DC input) | Logic 0 voltage threshold (DC input) | Output type | Static / PWM output | Pulse duty factor PWM | Switching voltage max | Width | Price | ||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
em4 B26 Local 16 In 10 Out 24V dc
Art:
88981103
Copied
|
16
|
10
|
Yes
|
2 k octets
|
Function block / SFC
|
Flash
|
FBD typically 1000 blocks
|
Yes
|
Up to 60 kHz
|
16 digital (8 analog)
|
0-10 V DC, 0-24 V DC, 0-20mA
|
15 V
|
9 V
|
2 SSR / PWM, 8 relays
|
Outputs O1 & O2
|
O1-O2: PWM 0-100% 100 Step, 14-1758 Hz
|
250 V AC
|
124.6 mm
|
| ||
|
em4 B26 Local Ethernet 16 In 10 Out 24V dc
Art:
88981133
Copied
|
16
|
10
|
Yes
|
2 k octets
|
Function block / SFC
|
Flash
|
FBD typically 1000 blocks
|
Yes
|
Up to 60 kHz
|
16 digital (8 analog)
|
0-10 V DC, 0-24 V DC, 0-20mA
|
15 V
|
9 V
|
2 SSR / PWM, 8 relays
|
Outputs O1 & O2
|
O1-O2: PWM 0-100% 100 Step, 14-1758 Hz
|
250 V AC
|
124.6 mm
|
| ||
|
em4 B26 Alert 3G 16 In 10 Out 24V dc
Art:
88981123
Copied
|
16
|
10
|
Yes
|
2 k octets
|
Function block / SFC
|
Flash
|
FBD typically 1000 blocks
|
Yes
|
Up to 60 kHz
|
16 digital (8 analog)
|
0-10 V DC, 0-24 V DC, 0-20mA
|
15 V
|
9 V
|
2 SSR / PWM, 8 relays
|
Outputs O1 & O2
|
O1-O2: PWM 0-100% 100 Step, 14-1758 Hz
|
250 V AC
|
124.6 mm
|
| ||
|
em4 E10R Digital Extension 6 In 4 Out 24V dc
Art:
88982113
Copied
|
6
|
4
|
|
|
|
|
|
|
|
Digital / 0-10V / 0-24V
|
0-10 V DC, 0-24 V DC
|
11 V
|
9 V
|
Relay
|
|
|
250 V AC
|
53.4 mm
|
| ||
|
em4 E10A Analogue Extension 6 In 4 Out 24V dc
Art:
88982213
Copied
|
6
|
4
|
|
|
|
|
|
No
|
|
Digital / 0-10V / 0-20mA / 4-20mA
|
0-10 V DC, 0-24 V DC, 0-20mA
|
11 V
|
8 V
|
O1-O2: SSR / PWM, O3-O4: 0-10V
|
|
O1-O2: PWM 0-100% 100 Step, 14-1758 Hz
|
|
53.4 mm
|
|
Select a variant in the list