STEGO
FTD 011 is two thermostats in the same casing. Available with one NO contact and one NC contact or with two NO contacts.
Â
Normally closed - Contact breaks (red casing) for regulating heaters or for switching signal devices when temperature has fallen below the minimum value. The contact opens when temperature is rising.
Â
Normally open - Â Contact makes(blue casing) for regulating filter fans, heat exchangers, cooling devices or for switching signal devices when temperature limit has been exceeded. The contact closes when temperaure is rising.
Â
The thermostat with one NO contact and one NC contact is used, for example, for controlling both a heater and fan.
Â
The thermostat has two NO contacts, good for controlling two fans. One of the thermostats activates first and a smaller fan, for example, is activated. If this fan is unable to cool sufficiently and the temperature thus increases, the other thermostat activates and a larger fan can be started.
Â
General data |
|
---|---|
Switch on temperature NC | 5 °C |
Switch off temperature NC | 15 °C |
Switch on temperature NO | 40 °C |
Switch off temperature NO | 50 °C |
Tolerance switch off | ±7K |
Tolerance for switch on | ±6K |
Detection | Bimetallic |
Contact type | 1 x N/O, 1 x N/C |
Rated operating conditions |
|
Voltage max | 250 V ac |
Inrush max | 16 A |
Breaking capacity | <250 VAC, 5 (1,6) A / 120 VAC, 10 (2) A. DC: 30W |
Contact resistance | <20 mΩ |
*Invisible Heading* |
|
---|---|
Operational temperature | -40°C ... +80°C |
Storage temperature | -45°C ... +80°C |
Life span | > 1000 000 cycles |
Dimensions |
|
Height | 47 mm |
Width | 63 mm |
Depth | 33 mm |
Weight | 0.04 kg |
Material plastic housing | Plastic |
Safety & approvals |
|
IP class | IP20 |
Approvals | CE, cULus, EAC, EMC, RoHS, UL E164102, VDE |
FTD 011 is two thermostats in the same casing. Available with one NO contact and one NC contact or with two NO contacts.
Â
Normally closed - Contact breaks (red casing) for regulating heaters or for switching signal devices when temperature has fallen below the minimum value. The contact opens when temperature is rising.
Â
Normally open - Â Contact makes(blue casing) for regulating filter fans, heat exchangers, cooling devices or for switching signal devices when temperature limit has been exceeded. The contact closes when temperaure is rising.
Â
The thermostat with one NO contact and one NC contact is used, for example, for controlling both a heater and fan.
Â
The thermostat has two NO contacts, good for controlling two fans. One of the thermostats activates first and a smaller fan, for example, is activated. If this fan is unable to cool sufficiently and the temperature thus increases, the other thermostat activates and a larger fan can be started.
Â
|
|
|
|
|
||
---|---|---|---|---|---|---|
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
Parts | Switch on temperature NC | Switch off temperature NC | Switch on temperature NO | Switch off temperature NO | Contact type | Price | ||
---|---|---|---|---|---|---|---|---|
![]()
FTD 011 15°C / 5°C (off/on), 50°C / 40°C (on/off) NC/NO
Art:
01163.0-00
Copied
|
5 °C
|
15 °C
|
40 °C
|
50 °C
|
1 x N/O, 1 x N/C
|
| ||
![]()
FTD 011 25°C / 15°C (off/on), 60°C / 65°C (on/off) NC/NO
Art:
01163.0-01
Copied
|
15 °C
|
25 °C
|
50 °C
|
60 °C
|
1 x N/O, 1 x N/C
|
| ||
![]()
FTD 011 15°C / 5°C (off/on), 35°C / 25°C (on/off) NC/NO
Art:
01163.0-02
Copied
|
5 °C
|
15 °C
|
25 °C
|
35 °C
|
1 x N/O, 1 x N/C
|
| ||
![]()
FTD 011 50°C / 40°C (off/on), 60°C / 50°C (on/off) NO/NO
Art:
01164.0-00
Copied
|
|
|
40 °C
|
60 °C
|
2 x N/O
|
|