STEGO
The DCR 030 is a compact DC operated high performance fan heater that prevents the formation of condensation and frost, whilst providing an evenly distributed air temperature inside enclosures.
This fan heater is designed be mounted directly on the bottom of the enclosure, in addition, the DCR 130 offers the same features, but can be mounted  on the enclosure wall or back plate.
The plastic housing provides double insulation and acts as protection against direct contact with the heating element.
The DCR range is available with an integrated electronic thermostat or electronic hygrostat, so negates the need for high current switching components.
For larger enclosures the DCR range has the option to use a ’plug in’ external sensor that can be mounted freely anywhere within the enclosure, they are available in 1m, 2m or 3M lengths.
The external sensor is not included but can be ordered separately. Please see accessories further down the page or see ‘External sensor for DCR fan heaters’
Â
General Data |
|
---|---|
Heat output | 200 W |
Nominal voltage | 24 V DC |
Heater body | Aluminium |
Material of body | Plastic |
Mounting | Screw fixing |
Number of fans | 1 |
Connection type | 2-pole push in connection clamp |
Recommended fuse (slow blow) | 25 A |
Life span | 50,000 h @ +25°C |
Air capacity | 160 m³/h |
Dimensions |
|
Height | 100 mm |
Width | 145 mm |
Depth | 166 mm |
*Invisible Heading* |
|
---|---|
Weight | 1.3 kg |
Safety & Approvals |
|
Protection class | II (double insulated) |
IP class | IP20 |
Approvals | CE, cRUus, EAC, RoHS, UL E234324, VDE |
Overheating protection | Automatic reset and second tier one shot fuse |
Rated Operating Conditions |
|
Operational temperature | -20°C ... +75°C |
Storage temperature | -40°C ... +80°C |
Operating humidity | < 90% RH |
Humidity storage | <90% RH |
Control range temperature from | -20 °C |
Control range temperature to | 40 °C |
Additional information | Thermostat with internal sensor |
The DCR 030 is a compact DC operated high performance fan heater that prevents the formation of condensation and frost, whilst providing an evenly distributed air temperature inside enclosures.
This fan heater is designed be mounted directly on the bottom of the enclosure, in addition, the DCR 130 offers the same features, but can be mounted  on the enclosure wall or back plate.
The plastic housing provides double insulation and acts as protection against direct contact with the heating element.
The DCR range is available with an integrated electronic thermostat or electronic hygrostat, so negates the need for high current switching components.
For larger enclosures the DCR range has the option to use a ’plug in’ external sensor that can be mounted freely anywhere within the enclosure, they are available in 1m, 2m or 3M lengths.
The external sensor is not included but can be ordered separately. Please see accessories further down the page or see ‘External sensor for DCR fan heaters’
Â
This innovative push-in connection system enables time savings of up to 50%, whether you're wiring control panels or managing complex installations
Solar energy has become a pillar of the global energy transition. The experts at OEM Automatic have broken down the role of photovoltaic fuses and their contribution to solar systems, as well as, how to choose the right solution for you.
Ultra fast-acting fuse links engineered specifically to shield delicate semiconductor devices.
Do you need reliable protection for measuring and control equipment? DEHN YellowLine delivers voltage surge protection tailored for building, measuring, and control systems
Choosing the right circuit breaker is important for protecting DC circuits. Two primary forms of protection are MCBs and ECBs. The experts at OEM Automatic breakdown the two circuit breakers for you!
New signal lights from Auer Signal are now available! The first products to be launched in this series are the Smart Dot 50 in the Basic and Standard versions, as well as the Smart Indicator 50 in the Basic version.Â
|
|
|
|
|
||
---|---|---|---|---|---|---|
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
Parts | Heat output | Nominal voltage | Control range temperature from | Control range temperature to | Control range humidity from | Control range humidity to | Additional information | Price | ||
---|---|---|---|---|---|---|---|---|---|---|
![]()
DCR 030 200W, 24 V DC, w/ internal sensor
Art:
03092.1-12
Copied
|
200 W
|
24 V DC
|
-20 °C
|
40 °C
|
|
|
Thermostat with internal sensor
|
| ||
![]()
DCR 030 200W, 24 V DC, w/ external sensor
Art:
03092.1-13
Copied
|
200 W
|
24 V DC
|
-20 °C
|
40 °C
|
|
|
Thermostat with connector for external sensor
|
| ||
![]()
DCR 030 800W, 56 V DC, w/ internal sensor
Art:
03097.3-12
Copied
|
800 W
|
56 V DC
|
-20 °C
|
40 °C
|
|
|
Thermostat with internal sensor
|
| ||
![]()
DCR 030 800W, 56 V DC, w/ external sensor
Art:
03097.3-13
Copied
|
800 W
|
56 V DC
|
-20 °C
|
40 °C
|
|
|
Thermostat with connector for external sensor
|
| ||
![]()
DCR 030 200W, 24 V DC, w/ external sensor
Art:
03092.1-03
Copied
|
200 W
|
24 V DC
|
|
|
40 % RF
|
90 % RF
|
Hygrostat with connector for external sensor
|
| ||
![]()
DCR 030 600W, 56 V DC, w/ external sensor
Art:
03095.1-03
Copied
|
600 W
|
56 V DC
|
|
|
40 % RF
|
90 % RF
|
Hygrostat with connector for external sensor
|
|
Select a variant in the list