General data |
|
---|---|
Control range temperature from | -20 °C |
Control range temperature to | 60 °C |
Tolerance switch off | ±1,5K |
Tolerance for switch on | ±1,5K |
Hysteresis temperature | 4K (±1,5K ) @ +20°C (+68°F) |
Detection | NTC |
Contact type | Changeover (SPDT) |
Colour | Light grey |
Rated operating conditions |
|
Voltage max | 60 V dc |
Voltage min | 10 V dc |
Breaking capacity | DC 0,5 A @ 48 V DC |
Operational temperature | -40°C ... +85°C |
Storage temperature | -40°C ... +85°C |
Breaking capacity min | DC 10 mW |
*Invisible Heading* |
|
---|---|
Life span | > 100,000 cycles |
Operating humidity | < 90% RH |
Humidity storage | <90% RH |
Dimensions |
|
Height | 64,5 mm |
Width | 42 mm |
Depth | 38 mm |
Weight | 0,07 kg |
Material plastic housing | Plastic |
Material of body | Plastic |
Tightening torque max | 0,5 |
Safety & approvals |
|
IP class | IP20 |
Approvals | CE, cULus, EAC, RoHS, UL, UL E164102, VDE |
Flammability class | UL94-V0 |
The electronic thermostat registers the surrounding air temperature and can switch a signal current via its internal relay with a potential-free change-over contact.
Signal-processing devices can be controlled directly with the ETL 011. In order to control heating and cooling equipment, filter fans and signal devices the switch module SM 010 or a similar device is needed.
The LED integrated in the adjustment knob shows the closed status of the contact 1-2.
When temperature is rising contact 1-2 opens and the LED turns off. In currentless state (no supply voltage) contact 1-2 opens.
|
|
|
|
|
||
---|---|---|---|---|---|---|
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
Parts | Control range temperature from | Control range temperature to | Control range temperature from | Control range temperature to | Price | ||
---|---|---|---|---|---|---|---|
![]()
ETL 011 Thermostat, -20°C…+60°C, change over, 12-48V dc
Art:
01131.2-00
Copied
|
-20 °C
|
60 °C
|
|
|
| ||
![]()
ETL 011 Thermostat, -4°F…+140°F, change over, 12-48V dc
Art:
01131.2-01
Copied
|
|
|
-4 °F
|
140 °F
|
|