STEGO
High humidity in a cabinet produces condensation and corrosion, which often leads to creep currents, flash-over, contact problems, etc.
The difference in temperature between night and day can often be sufficient for condensation to form. To prevent this, besides a thermostat that starts a heater before the set minimum temperature is reached, a hygrostat should also be mounted that starts the heater/fan if the humidity exceeds a set value. MFR012 has a change-over contact and can even be used to control air humidifiers if the air becomes too dry.
General data |
|
---|---|
Control range humidity from | 35 % RF |
Control range humidity to | 95 % RF |
Hysteresis humidity | 4% RH |
Mounting | Clip on, DIN rail |
Contact type | Changeover (SPDT) |
Colour | Light grey |
Rated operating conditions |
|
Breaking capacity | 250 VAC: 5 A. DC: 20 W. |
Contact resistance | <10 mΩ |
Electrical lifetime | > 50,000 cycles |
Connection type | 3-pole terminal for 2.5mm² |
Operational temperature | 0 °C ... +60°C |
Storage temperature | -40°C ... +60°C |
Life span | > 50,000 cycles |
*Invisible Heading* |
|
---|---|
Operating humidity | < 90% RH |
Humidity storage | <95% RH |
Dimensions |
|
Height | 67 mm |
Width | 50 mm |
Depth | 38 mm |
Weight | 0.06 kg |
Material of body | Plastic |
Safety & approvals |
|
IP class | IP20 |
Approvals | CE, cULus, EMC, RoHS, UL, UL E164102 |
Flammability class | UL94-V0 |
EMC | EN 55014-1-2, EN 61000-3-2, EN 61000-3-3 |
High humidity in a cabinet produces condensation and corrosion, which often leads to creep currents, flash-over, contact problems, etc.
The difference in temperature between night and day can often be sufficient for condensation to form. To prevent this, besides a thermostat that starts a heater before the set minimum temperature is reached, a hygrostat should also be mounted that starts the heater/fan if the humidity exceeds a set value. MFR012 has a change-over contact and can even be used to control air humidifiers if the air becomes too dry.
What tri-rated cable are you currently using? Does the product or service you receive leave you wanting more? It’s time to ask the question. Because now, you’ve got options.
This innovative push-in connection system enables time savings of up to 50%, whether you're wiring control panels or managing complex installations
Solar energy has become a pillar of the global energy transition. The experts at OEM Automatic have broken down the role of photovoltaic fuses and their contribution to solar systems, as well as, how to choose the right solution for you.
Ultra fast-acting fuse links engineered specifically to shield delicate semiconductor devices.
Do you need reliable protection for measuring and control equipment? DEHN YellowLine delivers voltage surge protection tailored for building, measuring, and control systems