STEGO
This electronic hygrotherm measures both humidity and temperature and switches a relay contact to control a heater or fan when one of the set values is reached.
The is model has the option of either a 1 or 2 m long external sensor, so it can be mounted in the best position within larger enclosures.
LED's indication is clearly visible behind each setting knob, indicate whent he ouput is active.
General data |
|
---|---|
Control range temperature from | 0 °C |
Control range temperature to | 60 °C |
Hysteresis temperature | 2K @ +25°C, 50% RH |
Control range humidity from | 50 % RF |
Control range humidity to | 90 % RF |
Hysteresis humidity | 4% RH @ +25°C, 50% RH |
Mounting | Clip on, DIN rail |
Contact type | Changeover (SPDT) |
Colour | Light grey |
Rated operating conditions |
|
Voltage max | 60 V dc |
Voltage min | 20 V dc |
Inrush max | 30 A |
Breaking capacity | Resistive load: 240 V AC 10 (1,6) A, inductive load, cosφ=0,6: 240 V AC 3 A, 120 V AC 3 A. 24 V DC 4 A |
Contact resistance | <10 mΩ |
Connection type | 5-pole terminal |
Operational temperature | -40°C ... +60°C |
*Invisible Heading* |
|
---|---|
Storage temperature | -40°C ... +60°C |
Life span | VDE: NO/NC > 15,000 cycles, UL: NO/NC > 30,000 cycles |
Operating humidity | < 90% RH |
Humidity storage | <90% RH |
Dimensions |
|
Height | 77 mm |
Width | 60 mm |
Depth | 43 mm |
Weight | 0.2 kg |
Material of body | Plastic |
Cable length | 1000 mm |
Safety & approvals |
|
IP class | IP20 |
Approvals | CE, cULus, EAC, RoHS, UL, UL E164102, VDE |
Flammability class | UL94-V0 |
EMC | EN 55014-1-2, EN 61000-3-2, EN 61000-3-3 |
This electronic hygrotherm measures both humidity and temperature and switches a relay contact to control a heater or fan when one of the set values is reached.
The is model has the option of either a 1 or 2 m long external sensor, so it can be mounted in the best position within larger enclosures.
LED's indication is clearly visible behind each setting knob, indicate whent he ouput is active.
What tri-rated cable are you currently using? Does the product or service you receive leave you wanting more? It’s time to ask the question. Because now, you’ve got options.
This innovative push-in connection system enables time savings of up to 50%, whether you're wiring control panels or managing complex installations
Solar energy has become a pillar of the global energy transition. The experts at OEM Automatic have broken down the role of photovoltaic fuses and their contribution to solar systems, as well as, how to choose the right solution for you.
Ultra fast-acting fuse links engineered specifically to shield delicate semiconductor devices.
Do you need reliable protection for measuring and control equipment? DEHN YellowLine delivers voltage surge protection tailored for building, measuring, and control systems
Choosing the right circuit breaker is important for protecting DC circuits. Two primary forms of protection are MCBs and ECBs. The experts at OEM Automatic breakdown the two circuit breakers for you!
|
|
|
|
|
||
---|---|---|---|---|---|---|
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
Parts | Voltage max | Voltage min | Cable length | Price | ||
---|---|---|---|---|---|---|
![]()
ETF 012 Hygro, 0…60°C, 50…90% RH, change over, 24-48V dc - 1m cable
Art:
01231.1-00
Copied
|
60 V dc
|
20 V dc
|
1000 mm
|
| ||
![]()
ETF 012 Hygro, 0…60°C, 50…90% RH, change over, 24-48V dc - 2m cable
Art:
01231.1-01
Copied
|
60 V dc
|
20 V dc
|
2000 mm
|
| ||
![]()
ETF 012 Hygro, 0…60°C, 50…90% RH, change over, 100-240V ac - 1m cable
Art:
01231.0-00
Copied
|
265 V ac
|
90 V ac
|
1000 mm
|
| ||
![]()
ETF 012 Hygro, 0…60°C, 50…90% RH, change over, 100-240V ac - 2m cable
Art:
01231.0-01
Copied
|
265 V ac
|
90 V ac
|
2000 mm
|
|
Select a variant in the list