LUMEL

Screen Recorder, KD7

The KD7 recorder is applied as a data acquisition station in measuring systems.
It suits applications to measure, visualize and supervise technical process parameters in various industrial branches, e.g. in pharmacy, food, chemical. It can be also used as an autonomous measuring and recording device.
KD7 recorder complies with the regulation 21 CFR Part 11, regulation for electronic records and signatures issued by Food and Drug Administration (FDA).
KD7 recorder is distinguished by:

  • easy and intuitive servicing based on the graphical Windows and touch panel
  • the following communication interfaces are available: RS-232, RS-485 MODBUS Master and Slave, MODBUS Slave TCP/IP (NEW),
    ETHERNET 10 Base-T, USB 1.1 Device
  • possibility to exchange of configuration data between the recorder and PC through the USB interface or the CompactFlash card
  • HTTP server” (WWW) enables to carry out through the WWW browser, the preview of the recorder current state* and the sampling
  • mathematical functions
  • archiving and visualisation of measuring data transmitted to KD7 from external devices via RS-485 MODBUS or Ethernet

MEASURING INPUTS and OUTPUTS
Depending on the model, KD7 has:

  • 6 or 12 galvanically isolated analog measuring channels
  • 16 measuring channels for data transmitted through communication interfaces
  • 16 or 32 alarms and 8 or 16 digital inputs
  • 4 or 8 analog outputs


DATA PRESENTATION
To illustrate the process run, the customer can choose many forms of data presentation:

  • linear, bar trends, and circular
  • digital and analog indicators
  • statistics
  • Each channel has the possibility to assign settings as: colour, name, range and presentation view

 

DATA ARCHIVING
For data archiving KD7 recorder has:

  • exchangeable external memory (CompactFlash card), from 16 MB up to 4 GB
  • 6 MB internal memory with data support

 

SECURITY
To ensure the recorder is secure in the network, each customer can individually login, password protect and configure the access rights to the recorder archive memory.

PC SOFTWARE
KD7 SETUP, KD ARCHIVING, KD CHECK and KD CONNECT programs are destined for KD7 recorder servicing:

  • the KD7 SETUP program is used to configure the KD7 recorder
  • the KD ARCHIVING program is designed for visualization, printout and export to CSV format, data recorded in the binary format with digital signature, obtained from the recorder
  • the KD CONNECT program provides the communication between PC and the KD7 recorder through the USB link. It enables the acquisition of archived data from the recorder, writing and erasing data on the CF card
  • the KD CHECK program is used for verification of the digital signature in archive
Read more
  • Upto 24 measuring channels
  • WWW and FTP server
  • RS-232, RS-485 and USB serial interfaces
  • 5.7" LCD screen

Selected variant

Selected variant

Technical data

Product description

The KD7 recorder is applied as a data acquisition station in measuring systems.
It suits applications to measure, visualize and supervise technical process parameters in various industrial branches, e.g. in pharmacy, food, chemical. It can be also used as an autonomous measuring and recording device.
KD7 recorder complies with the regulation 21 CFR Part 11, regulation for electronic records and signatures issued by Food and Drug Administration (FDA).
KD7 recorder is distinguished by:

  • easy and intuitive servicing based on the graphical Windows and touch panel
  • the following communication interfaces are available: RS-232, RS-485 MODBUS Master and Slave, MODBUS Slave TCP/IP (NEW),
    ETHERNET 10 Base-T, USB 1.1 Device
  • possibility to exchange of configuration data between the recorder and PC through the USB interface or the CompactFlash card
  • HTTP server” (WWW) enables to carry out through the WWW browser, the preview of the recorder current state* and the sampling
  • mathematical functions
  • archiving and visualisation of measuring data transmitted to KD7 from external devices via RS-485 MODBUS or Ethernet

MEASURING INPUTS and OUTPUTS
Depending on the model, KD7 has:

  • 6 or 12 galvanically isolated analog measuring channels
  • 16 measuring channels for data transmitted through communication interfaces
  • 16 or 32 alarms and 8 or 16 digital inputs
  • 4 or 8 analog outputs


DATA PRESENTATION
To illustrate the process run, the customer can choose many forms of data presentation:

  • linear, bar trends, and circular
  • digital and analog indicators
  • statistics
  • Each channel has the possibility to assign settings as: colour, name, range and presentation view

 

DATA ARCHIVING
For data archiving KD7 recorder has:

  • exchangeable external memory (CompactFlash card), from 16 MB up to 4 GB
  • 6 MB internal memory with data support

 

SECURITY
To ensure the recorder is secure in the network, each customer can individually login, password protect and configure the access rights to the recorder archive memory.

PC SOFTWARE
KD7 SETUP, KD ARCHIVING, KD CHECK and KD CONNECT programs are destined for KD7 recorder servicing:

  • the KD7 SETUP program is used to configure the KD7 recorder
  • the KD ARCHIVING program is designed for visualization, printout and export to CSV format, data recorded in the binary format with digital signature, obtained from the recorder
  • the KD CONNECT program provides the communication between PC and the KD7 recorder through the USB link. It enables the acquisition of archived data from the recorder, writing and erasing data on the CF card
  • the KD CHECK program is used for verification of the digital signature in archive

Accessories

Parts Price

Selected variant

Select a variant in the list

Contact us

If you need any help, you can contact us in one of the following ways:

phone 0116 284 9900

Send an e-mail Send an e-mail

comments Use live chat

Logo

Cookie settings for OEM.CO.UK

Cookies help us improve your experience with us, so in order to be able to handle login information, offer you personalised content and for basic functionality of this website, we use some cookies.

We will never sell on any information about you. 

You can accept all cookies or personalise your cookies preferences, you can also change your cookie preferences at any time by visiting our contact page.

Necessary Cookies

These cookies are necessary for the website to work and can not be turned off in our systems. They are usually used only in response to actions you have taken in connection with a service request, for example when setting personal preferences, logging in or filling out a form.

Analysis and measurement cookies

These cookies allow us to count the number of visits and traffic sources so that we can measure and improve our website performance. They help us know which pages are more or less popular and how visitors navigate around the site. The information that these cookies collect is aggregated and therefore completely anonymous. If you do not allow these cookies, we do not know when you have visited our website.

Marketing cookies

These cookies can be added by our partners. They can use them to create a profile of you, based on your interests, to show you more relevant information. They do not store any personal information - only information about your browser and device. If you do not accept these cookies, you will have a more general and less customized user experience.