KÜBLER
Indication counter with selectable functions such as: pulse counter, Frequency display, Position displays without limit values, Tachometer without limitvalues hour meters / timers and short-time meter.
LED display with 6 x digits, 8 mm. The counter is programmed using the two buttons at the front of the counter. These buttons can also be locked if so required. The counter has two counter inputs. Built-in memory backup EEPROM. Cable connection with screw terminal. The counter comes with clamps, gaskets and separate front frames to fit 25x50 mm panel holes. One for screw fitting and one without.
Pulse counter
For counting and adding pulses, also works as a position counter together with an angle sensor. The counter function is selected during programming
Cnt.dir | A=counter input | Quad | A=0° (designed for two-channel angle sensor) |
Up.dn | A=counting up | Quad2 | Same as quad, but multiplies the pulse count by 2. |
Chronometer/timer
For timing where the outputs are activated once a preset time is reached. Adjustable time ranges in one of the following ranges: h or min or sec, or h:min:s (e.g. 06 h:23 min:45 sec). The position of the decimal point determines the resolution of the time selected, e.g. whole seconds, tenths and hundredths of a second.
Tachometer/frequency/revolution counter
For displaying speed, e.g. rpm or metres per second. The counter speed can be selected between 30 Hz or 20 kHz.
User-friendly and versatile Large keys that can be operated even while wearing gloves Programming: Straightforward and consistent programming and operation using plain text programming. Access to programming is possible during operation, with safety prompts in place. Adjustable scaling on an individual basis Multiplication and division factors ranging from 0.0001 to 99.9999, enabling the calculation of corresponding units such as position in 1/10 mm and speed in RPM. Four different counter input types available for position display: counting direction, difference or addition mode, phase discriminator with single, double, or quadruple evaluation Frequency measurement with the option to display in 1/min or 1/sec Time counting: Pulse width or period duration measurement in hours, minutes, or seconds, along with real-time display capability Inputs: In addition to HTL inputs, devices with 4 to 30 V DC input level can also be used as parallel displays for PLC. Optional output: Provides a 0 signal for position and counting, allows for standstill monitoring at speed, and offers a 1 Hz cycle during active timing.
Connection | Screw terminal |
---|---|
Depth | 59 mm |
Digit height | 8 mm |
EMC | EN55011, 2004/108/EC, EN 61000-3-2, EN 61000-3-3 |
Height | 24 mm |
Input impedance, typ | 5 kΩ |
IP class | IP65 |
Material | Plastic |
Mounting | Panel mount |
Number colour | Red |
Number of digits | 6 |
Operating voltage dc max | 30 V |
---|---|
Operating voltage dc min | 10 V |
Panel size | 24x48 mm |
Polarity | Yes |
Storage temperature max | 70 °C |
Storage temperature min | -25 °C |
Temperature operational max | 65 °C |
Temperature operational min | -20 °C |
Weight | 50 g |
Width | 48 mm |
Indication counter with selectable functions such as: pulse counter, Frequency display, Position displays without limit values, Tachometer without limitvalues hour meters / timers and short-time meter.
LED display with 6 x digits, 8 mm. The counter is programmed using the two buttons at the front of the counter. These buttons can also be locked if so required. The counter has two counter inputs. Built-in memory backup EEPROM. Cable connection with screw terminal. The counter comes with clamps, gaskets and separate front frames to fit 25x50 mm panel holes. One for screw fitting and one without.
Pulse counter
For counting and adding pulses, also works as a position counter together with an angle sensor. The counter function is selected during programming
Cnt.dir | A=counter input | Quad | A=0° (designed for two-channel angle sensor) |
Up.dn | A=counting up | Quad2 | Same as quad, but multiplies the pulse count by 2. |
Chronometer/timer
For timing where the outputs are activated once a preset time is reached. Adjustable time ranges in one of the following ranges: h or min or sec, or h:min:s (e.g. 06 h:23 min:45 sec). The position of the decimal point determines the resolution of the time selected, e.g. whole seconds, tenths and hundredths of a second.
Tachometer/frequency/revolution counter
For displaying speed, e.g. rpm or metres per second. The counter speed can be selected between 30 Hz or 20 kHz.
User-friendly and versatile Large keys that can be operated even while wearing gloves Programming: Straightforward and consistent programming and operation using plain text programming. Access to programming is possible during operation, with safety prompts in place. Adjustable scaling on an individual basis Multiplication and division factors ranging from 0.0001 to 99.9999, enabling the calculation of corresponding units such as position in 1/10 mm and speed in RPM. Four different counter input types available for position display: counting direction, difference or addition mode, phase discriminator with single, double, or quadruple evaluation Frequency measurement with the option to display in 1/min or 1/sec Time counting: Pulse width or period duration measurement in hours, minutes, or seconds, along with real-time display capability Inputs: In addition to HTL inputs, devices with 4 to 30 V DC input level can also be used as parallel displays for PLC. Optional output: Provides a 0 signal for position and counting, allows for standstill monitoring at speed, and offers a 1 Hz cycle during active timing.
We shine a spotlight on surge protection devices (SPDs), a crucial yet often overlooked component in industrial settings. Every surge of electricity, every fluctuation in voltage, poses a potential threat to your machinery and systems.
Renowned for high-quality cable cutting and crimping tools, Klauke serves electrical contractors, cable jointers, and linemen across a spectrum of sectors
At OEM Automatic, we can supply a series of components for your one project. All under one roof. This case study discusses how we supplied several components for our customer's new electro-pneumatic control box.
To promote constant and reliable performance, as well as a longer life of parts in the vehicle, it is important to consider the right cable protector.
We have now added switch disconnectors to our range! Switch disconnectors contribute to the overall functionality and safety of electrical systems.
LOCC-Box from Lutze is an intelligent current monitoring device that provides reliable protection of DC circuits in a slimline 8.1mm housing.
|
|
|
|
|
||
---|---|---|---|---|---|---|
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
Parts | Price | ||
---|---|---|---|
CODIX 524 LED DISPLAY 10-30VDC
Art:
6.524.012.300
Copied
|
|
Select a variant in the list
If you need any help, you can contact us in one of the following ways: