General Data |
|
|---|---|
| Thread Size (G) | M10 |
| Inner thread size | M10 |
| Insert Type | One-Piece |
| Cable diameter min | 4 mm |
| Cable diameter max | 6 mm |
| IP class | Cable gland IP 68 |
Dimensions |
|
| Thread pitch | 1.5 |
| Inner thread pitch | 1.5 mm |
| Thread length | 10 mm |
| Height (H) | 30 mm |
| Spanner width (AF) | 13 mm |
Materials |
|
| Material | Nickel-plated brass |
*Invisible Heading* |
|
|---|---|
| Materials O-ring | NBR |
| Material of seals | TPE |
| Temperature range | -40°C ... +100°C |
Approvals |
|
| Approvals | SEV, CE, DNV, EAC, VDE |
| Strain relief | Version A acc. to EN 62444 |
Additional Data |
|
| Pack size | 50 |
| Country of origin | CH |
| Tariff code | 74199949 |
| Weight | 18.42 g |
| Additional features | Max. clamping range depends on conduit inner diameter |
|
|
|
|
|
|
||
|---|---|---|---|---|---|---|
|
|
|
|
|
|
||
|
|
|
|
|
|
||
|
|
|
|
|
|
||
|
|
|
|
|
|
||
|
|
|
|
|
|
||
|
|
|
|
|
|
| Parts | Thread Size (G) | Inner thread size | Insert Type | Cable diameter inner min | Cable diameter inner max | Cable diameter min | Cable diameter max | IP class | Thread pitch | Inner thread pitch | Thread length | Height (H) | Spanner width (AF) | Diameter | Inner diameter | Conduit diameter (AD) | Material | Materials O-ring | Material of seals | Contact sleeve material | Temperature range | Approvals | Strain relief | Pack size | Country of origin | Tariff code | Weight | Additional features | Price | ||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Adapter NPB, M10, long, ø4…6mm
Art:
1165.10
Copied
|
M10
|
M10
|
One-Piece
|
|
|
4 mm
|
6 mm
|
Cable gland IP 68
|
1.5
|
1.5 mm
|
10 mm
|
30 mm
|
13 mm
|
|
|
|
Nickel-plated brass
|
NBR
|
TPE
|
|
-40°C ... +100°C
|
SEV, CE, DNV, EAC, VDE
|
Version A acc. to EN 62444
|
50
|
CH
|
74199949
|
18.42 g
|
Max. clamping range depends on conduit inner diameter
|
|
||
Adapter NPB, M12, long, ø5.5…6.5mm
Art:
1165.12
Copied
|
M12
|
M12
|
One-Piece
|
|
|
5 mm
|
6.5 mm
|
Cable gland IP 68
|
1.5
|
1.5 mm
|
10 mm
|
32 mm
|
15 mm
|
|
|
|
Nickel-plated brass
|
NBR
|
TPE
|
|
-40°C ... +100°C
|
SEV, CE, DNV, EAC, VDE
|
Version A acc. to EN 62444
|
50
|
CH
|
74199949
|
24.58 g
|
Max. clamping range depends on conduit inner diameter
|
|
||
Adapter NPB, M16, long, ø6…8mm
Art:
1165.17
Copied
|
M16
|
M16
|
Two-Piece
|
6 mm
|
8 mm
|
8 mm
|
10.5 mm
|
Cable gland IP 68
|
1.5
|
1.5 mm
|
10 mm
|
35 mm
|
18 mm
|
|
|
|
Nickel-plated brass
|
NBR
|
TPE
|
|
-40°C ... +100°C
|
SEV, CE, DNV, EAC, VDE
|
Version A acc. to EN 62444
|
50
|
CH
|
74199949
|
32.7 g
|
Max. clamping range depends on conduit inner diameter
|
|
||
Adapter NPB, M20, long, ø8…14.5mm
Art:
1165.20
Copied
|
M20
|
M20
|
Two-Piece
|
8 mm
|
11 mm
|
11 mm
|
14.5 mm
|
Cable gland IP 68
|
1.5
|
1.5 mm
|
10 mm
|
36 mm
|
24 mm
|
|
|
|
Nickel-plated brass
|
NBR
|
TPE
|
|
-40°C ... +100°C
|
SEV, CE, DNV, EAC, VDE
|
Version A acc. to EN 62444
|
25
|
CH
|
74199949
|
59.08 g
|
Max. clamping range depends on conduit inner diameter
|
|
||
Adapter NPB, M25, long, ø12.5…19mm
Art:
1165.25
Copied
|
M25
|
M25
|
Two-Piece
|
12.5 mm
|
16 mm
|
16 mm
|
19 mm
|
Cable gland IP 68
|
1.5
|
1.5 mm
|
11 mm
|
41 mm
|
30 mm
|
|
|
|
Nickel-plated brass
|
NBR
|
TPE
|
|
-40°C ... +100°C
|
SEV, CE, DNV, EAC, VDE
|
Version A acc. to EN 62444
|
25
|
CH
|
74199949
|
98.76 g
|
Max. clamping range depends on conduit inner diameter
|
|
||
Adapter NPB, M32, long, ø17…25.5mm
Art:
1165.32
Copied
|
M32
|
M32
|
Two-Piece
|
17 mm
|
21 mm
|
21 mm
|
25.5 mm
|
Cable gland IP 68
|
1.5
|
1.5 mm
|
13 mm
|
46 mm
|
36 mm
|
|
|
|
Nickel-plated brass
|
NBR
|
TPE
|
|
-40°C ... +100°C
|
SEV, CE, DNV, EAC, VDE
|
Version A acc. to EN 62444
|
25
|
CH
|
74199949
|
142.52 g
|
Max. clamping range depends on conduit inner diameter
|
|
||
Adapter NPB, M40, long, ø24…33mm
Art:
1165.40
Copied
|
M40
|
M40
|
Two-Piece
|
24 mm
|
28.5 mm
|
28.5 mm
|
33 mm
|
Cable gland IP 68
|
1.5
|
1.5 mm
|
13 mm
|
48 mm
|
46 mm
|
|
|
|
Nickel-plated brass
|
NBR
|
TPE
|
|
-40°C ... +100°C
|
SEV, CE, DNV, EAC, VDE
|
Version A acc. to EN 62444
|
10
|
CH
|
74199949
|
240.1 g
|
Max. clamping range depends on conduit inner diameter
|
|
||
Adapter NPB, M50, long, ø33…42mm
Art:
1165.50
Copied
|
M50
|
M50
|
Two-Piece
|
33 mm
|
37 mm
|
37 mm
|
42 mm
|
Cable gland IP 68
|
1.5
|
1.5 mm
|
14 mm
|
53 mm
|
55 mm
|
|
|
|
Nickel-plated brass
|
NBR
|
TPE
|
|
-40°C ... +100°C
|
SEV, CE, DNV, EAC, VDE
|
Version A acc. to EN 62444
|
5
|
CH
|
74199949
|
317.2 g
|
Max. clamping range depends on conduit inner diameter
|
|
||
Adapter NPB, M63, long, ø40…52mm
Art:
1165.63
Copied
|
M63
|
M63
|
Two-Piece
|
40 mm
|
46 mm
|
46 mm
|
52 mm
|
Cable gland IP 68
|
1.5
|
1.5 mm
|
14 mm
|
56 mm
|
70 mm
|
|
|
|
Nickel-plated brass
|
NBR
|
TPE
|
|
-40°C ... +100°C
|
SEV, CE, DNV, EAC, VDE
|
Version A acc. to EN 62444
|
5
|
CH
|
74199949
|
454 g
|
Max. clamping range depends on conduit inner diameter
|
|
||
Adapter NPB, Pg 7, long, ø5…6.5mm
Art:
1165.07
Copied
|
PG 7
|
PG 7
|
One-Piece
|
|
|
5 mm
|
6.5 mm
|
Cable gland IP 68
|
|
|
10 mm
|
30 mm
|
15 mm
|
|
|
|
Nickel-plated brass
|
NBR
|
TPE
|
|
-40°C ... +100°C
|
EAC
|
|
50
|
CH
|
74199949
|
23.6 g
|
Max. clamping range depends on conduit inner diameter
|
|
||
Adapter NPB, Pg 9, long, ø6…10.5mm
Art:
1165.09
Copied
|
PG 9
|
PG 9
|
Two-Piece
|
6 mm
|
8 mm
|
8 mm
|
10.5 mm
|
Cable gland IP 68
|
|
|
10 mm
|
35 mm
|
18 mm
|
|
|
|
Nickel-plated brass
|
NBR
|
TPE
|
|
-40°C ... +100°C
|
EAC
|
|
50
|
CH
|
74199949
|
33.8 g
|
Max. clamping range depends on conduit inner diameter
|
|
||
Adapter NPB, Pg 11, long, ø5.5…12mm
Art:
1165.11
Copied
|
PG 11
|
PG 11
|
Two-Piece
|
5.5 mm
|
8.5 mm
|
8.5 mm
|
12 mm
|
Cable gland IP 68
|
|
|
10 mm
|
36 mm
|
21 mm
|
|
|
|
Nickel-plated brass
|
NBR
|
TPE
|
|
-40°C ... +100°C
|
EAC
|
|
50
|
CH
|
74199949
|
47.88 g
|
Max. clamping range depends on conduit inner diameter
|
|
||
Adapter NPB, Pg 13, long, ø8…14.5mm
Art:
1165.13
Copied
|
PG 13
|
PG 13
|
Two-Piece
|
8 mm
|
11 mm
|
11 mm
|
14.5 mm
|
Cable gland IP 68
|
|
|
10 mm
|
36 mm
|
24 mm
|
|
|
|
Nickel-plated brass
|
NBR
|
TPE
|
|
-40°C ... +100°C
|
EAC
|
|
25
|
CH
|
74199949
|
59.94 g
|
Max. clamping range depends on conduit inner diameter
|
|
||
Adapter NPB, Pg 16, long, ø8…14.5mm
Art:
1165.16
Copied
|
PG 16
|
PG 16
|
Two-Piece
|
8 mm
|
11 mm
|
11 mm
|
14.5 mm
|
Cable gland IP 68
|
|
|
10 mm
|
37 mm
|
24 mm
|
|
|
|
Nickel-plated brass
|
NBR
|
TPE
|
|
-40°C ... +100°C
|
EAC
|
|
25
|
CH
|
74199949
|
62 g
|
Max. clamping range depends on conduit inner diameter
|
|
||
Adapter NPB, Pg 21, long, ø12.5…19mm
Art:
1165.21
Copied
|
PG 21
|
PG 21
|
Two-Piece
|
12.5 mm
|
16 mm
|
16 mm
|
19 mm
|
Cable gland IP 68
|
|
|
12 mm
|
42 mm
|
30 mm
|
|
|
|
Nickel-plated brass
|
NBR
|
TPE
|
|
-40°C ... +100°C
|
EAC
|
|
25
|
CH
|
74199949
|
106 g
|
Max. clamping range depends on conduit inner diameter
|
|
||
Adapter NPB, Pg 29, long, ø19…27.5mm
Art:
1165.29
Copied
|
PG 29
|
PG 29
|
Two-Piece
|
19 mm
|
23 mm
|
23 mm
|
27.5 mm
|
Cable gland IP 68
|
|
|
12 mm
|
45 mm
|
40 mm
|
|
|
|
Nickel-plated brass
|
NBR
|
TPE
|
|
-40°C ... +100°C
|
EAC
|
|
25
|
CH
|
74199949
|
181.68 g
|
Max. clamping range depends on conduit inner diameter
|
|
||
Adapter NPB, Pg 36, long, ø26…35mm
Art:
1165.36
Copied
|
PG 36
|
PG 36
|
Two-Piece
|
26 mm
|
30.5 mm
|
30.5 mm
|
35 mm
|
Cable gland IP 68
|
|
|
15 mm
|
52 mm
|
50 mm
|
|
|
|
Nickel-plated brass
|
NBR
|
TPE
|
|
-40°C ... +100°C
|
EAC
|
|
10
|
CH
|
74199949
|
296.7 g
|
Max. clamping range depends on conduit inner diameter
|
|
||
Adapter NPB, Pg 48, long, ø37…49mm
Art:
1165.48
Copied
|
PG 48
|
PG 48
|
Two-Piece
|
37 mm
|
43 mm
|
43 mm
|
49 mm
|
Cable gland IP 68
|
|
|
15 mm
|
56 mm
|
65 mm
|
|
|
|
Nickel-plated brass
|
NBR
|
TPE
|
|
-40°C ... +100°C
|
EAC
|
|
5
|
CH
|
74199949
|
508.6 g
|
Max. clamping range depends on conduit inner diameter
|
|
||
Adapter EMC NPB, M10, long, ø3…4mm
Art:
1165.80.10.040
Copied
|
M10
|
M10
|
One-Piece
|
|
|
3 mm
|
4 mm
|
Cable gland IP 68
|
1.5
|
1.5 mm
|
10 mm
|
32 mm
|
13 mm
|
|
|
|
Nickel-plated brass
|
NBR
|
TPE
|
Nickel-plated brass
|
-40°C ... +100°C
|
SEV, CE, DNV, EAC, VDE
|
Version A acc. to EN 62444
|
50
|
CH
|
74199949
|
18.58 g
|
Max. clamping range depends on conduit inner diameter
|
|
||
Adapter EMC NPB, M10, long, ø4…6mm
Art:
1165.80.10.060
Copied
|
M10
|
M10
|
One-Piece
|
|
|
4 mm
|
6 mm
|
Cable gland IP 68
|
1.5
|
1.5 mm
|
10 mm
|
32 mm
|
13 mm
|
|
|
|
Nickel-plated brass
|
NBR
|
TPE
|
Nickel-plated brass
|
-40°C ... +100°C
|
SEV, CE, DNV, EAC, VDE
|
Version A acc. to EN 62444
|
50
|
CH
|
74199949
|
18.58 g
|
Max. clamping range depends on conduit inner diameter
|
|
||
Adapter EMC NPB, M12, long, ø4.5…6mm
Art:
1165.80.12.060
Copied
|
M12
|
M12
|
One-Piece
|
|
|
4.5 mm
|
6 mm
|
Cable gland IP 68
|
1.5
|
1.5 mm
|
10 mm
|
34 mm
|
15 mm
|
|
|
|
Nickel-plated brass
|
NBR
|
TPE
|
Nickel-plated brass
|
-40°C ... +100°C
|
SEV, CE, DNV, EAC, VDE
|
Version A acc. to EN 62444
|
50
|
CH
|
74199949
|
33.7 g
|
Max. clamping range depends on conduit inner diameter
|
|
||
Adapter EMC NPB, M12, long, ø6…7.5mm
Art:
1165.80.12.075
Copied
|
M12
|
M12
|
One-Piece
|
|
|
6 mm
|
7.5 mm
|
Cable gland IP 68
|
1.5
|
1.5 mm
|
10 mm
|
34 mm
|
15 mm
|
|
|
|
Nickel-plated brass
|
NBR
|
TPE
|
Nickel-plated brass
|
-40°C ... +100°C
|
SEV, CE, DNV, EAC, VDE
|
Version A acc. to EN 62444
|
50
|
CH
|
74199949
|
27.44 g
|
Max. clamping range depends on conduit inner diameter
|
|
||
Adapter EMC NPB, M16, long, ø6…8mm
Art:
1165.80.17.080
Copied
|
M16
|
M16
|
One-Piece
|
|
|
6 mm
|
8 mm
|
Cable gland IP 68
|
1.5
|
1.5 mm
|
10 mm
|
38 mm
|
18 mm
|
|
|
|
Nickel-plated brass
|
NBR
|
TPE
|
Nickel-plated brass
|
-40°C ... +100°C
|
SEV, CE, DNV, EAC, VDE
|
Version A acc. to EN 62444
|
50
|
CH
|
74199949
|
36.56 g
|
Max. clamping range depends on conduit inner diameter
|
|
||
Adapter EMC NPB, M16, long, ø8…10mm
Art:
1165.80.17.100
Copied
|
M16
|
M16
|
One-Piece
|
|
|
8 mm
|
10 mm
|
Cable gland IP 68
|
1.5
|
1.5 mm
|
10 mm
|
38 mm
|
18 mm
|
|
|
|
Nickel-plated brass
|
NBR
|
TPE
|
Nickel-plated brass
|
-40°C ... +100°C
|
SEV, CE, DNV, EAC, VDE
|
Version A acc. to EN 62444
|
50
|
CH
|
74199949
|
38.6 g
|
Max. clamping range depends on conduit inner diameter
|
|
||
Adapter EMC NPB, M20, long, ø8…11mm
Art:
1165.80.20.110
Copied
|
M20
|
M20
|
One-Piece
|
|
|
8 mm
|
11 mm
|
Cable gland IP 68
|
1.5
|
1.5 mm
|
10 mm
|
40 mm
|
24 mm
|
|
|
|
Nickel-plated brass
|
NBR
|
TPE
|
Nickel-plated brass
|
-40°C ... +100°C
|
SEV, CE, DNV, EAC, VDE
|
Version A acc. to EN 62444
|
25
|
CH
|
74199949
|
74.2 g
|
Max. clamping range depends on conduit inner diameter
|
|
||
Adapter EMC NPB, M20, long, ø11…14mm
Art:
1165.80.20.140
Copied
|
M20
|
M20
|
One-Piece
|
|
|
11 mm
|
14 mm
|
Cable gland IP 68
|
1.5
|
1.5 mm
|
10 mm
|
40 mm
|
24 mm
|
|
|
|
Nickel-plated brass
|
NBR
|
TPE
|
Nickel-plated brass
|
-40°C ... +100°C
|
SEV, CE, DNV, EAC, VDE
|
Version A acc. to EN 62444
|
25
|
CH
|
74199949
|
68.8 g
|
Max. clamping range depends on conduit inner diameter
|
|
||
Adapter EMC NPB, M25, long, ø13…16mm
Art:
1165.80.25.160
Copied
|
M25
|
M25
|
One-Piece
|
|
|
13 mm
|
16 mm
|
Cable gland IP 68
|
1.5
|
1.5 mm
|
11 mm
|
46 mm
|
30 mm
|
|
|
|
Nickel-plated brass
|
NBR
|
TPE
|
Nickel-plated brass
|
-40°C ... +100°C
|
SEV, CE, DNV, EAC, VDE
|
Version A acc. to EN 62444
|
25
|
CH
|
74199949
|
112 g
|
Max. clamping range depends on conduit inner diameter
|
|
||
Adapter EMC NPB, M25, long, ø16…19mm
Art:
1165.80.25.190
Copied
|
M25
|
M25
|
One-Piece
|
|
|
16 mm
|
19 mm
|
Cable gland IP 68
|
1.5
|
1.5 mm
|
11 mm
|
46 mm
|
30 mm
|
|
|
|
Nickel-plated brass
|
NBR
|
TPE
|
Nickel-plated brass
|
-40°C ... +100°C
|
SEV, CE, DNV, EAC, VDE
|
Version A acc. to EN 62444
|
25
|
CH
|
74199949
|
112.1 g
|
Max. clamping range depends on conduit inner diameter
|
|
||
Adapter EMC NPB, M32, long, ø18…21mm
Art:
1165.80.32.210
Copied
|
M32
|
M32
|
One-Piece
|
|
|
18 mm
|
21 mm
|
Cable gland IP 68
|
1.5
|
1.5 mm
|
13 mm
|
49 mm
|
36 mm
|
|
|
|
Nickel-plated brass
|
NBR
|
TPE
|
Nickel-plated brass
|
-40°C ... +100°C
|
SEV, CE, DNV, EAC, VDE
|
Version A acc. to EN 62444
|
10
|
CH
|
74199949
|
164 g
|
Max. clamping range depends on conduit inner diameter
|
|
||
Adapter EMC NPB, M32, long, ø21…25mm
Art:
1165.80.32.250
Copied
|
M32
|
M32
|
One-Piece
|
|
|
21 mm
|
25 mm
|
Cable gland IP 68
|
1.5
|
1.5 mm
|
13 mm
|
49 mm
|
36 mm
|
|
|
|
Nickel-plated brass
|
NBR
|
TPE
|
Nickel-plated brass
|
-40°C ... +100°C
|
SEV, CE, DNV, EAC, VDE
|
Version A acc. to EN 62444
|
10
|
CH
|
74199949
|
157.3 g
|
Max. clamping range depends on conduit inner diameter
|
|
||
Adapter EMC NPB, M40, long, ø24…28.5mm
Art:
1165.80.40.285
Copied
|
M40
|
M40
|
One-Piece
|
|
|
24 mm
|
28.5 mm
|
Cable gland IP 68
|
1.5
|
1.5 mm
|
13 mm
|
51 mm
|
46 mm
|
|
|
|
Nickel-plated brass
|
NBR
|
TPE
|
Nickel-plated brass
|
-40°C ... +100°C
|
SEV, CE, DNV, EAC, VDE
|
Version A acc. to EN 62444
|
10
|
CH
|
74199949
|
250 g
|
Max. clamping range depends on conduit inner diameter
|
|
||
Adapter EMC NPB, M40, long, ø28.5…32mm
Art:
1165.80.40.320
Copied
|
M40
|
M40
|
One-Piece
|
|
|
28.5 mm
|
32 mm
|
Cable gland IP 68
|
1.5
|
1.5 mm
|
13 mm
|
51 mm
|
46 mm
|
|
|
|
Nickel-plated brass
|
NBR
|
TPE
|
Nickel-plated brass
|
-40°C ... +100°C
|
SEV, CE, DNV, EAC, VDE
|
Version A acc. to EN 62444
|
10
|
CH
|
74199949
|
272 g
|
Max. clamping range depends on conduit inner diameter
|
|
||
Adapter EMC NPB, M50, long, ø33…37mm
Art:
1165.80.50.370
Copied
|
M50
|
M50
|
One-Piece
|
|
|
33 mm
|
37 mm
|
Cable gland IP 68
|
1.5
|
1.5 mm
|
14 mm
|
55 mm
|
55 mm
|
|
|
|
Nickel-plated brass
|
NBR
|
TPE
|
Nickel-plated brass
|
-40°C ... +100°C
|
SEV, CE, DNV, EAC, VDE
|
Version A acc. to EN 62444
|
5
|
CH
|
74199949
|
355.3 g
|
Max. clamping range depends on conduit inner diameter
|
|
||
Adapter EMC NPB, M63, long, ø46…50mm
Art:
1165.80.63.500
Copied
|
M63
|
M63
|
One-Piece
|
|
|
46 mm
|
50 mm
|
Cable gland IP 68
|
1.5
|
1.5 mm
|
14 mm
|
59 mm
|
70 mm
|
|
|
|
Nickel-plated brass
|
NBR
|
TPE
|
Nickel-plated brass
|
-40°C ... +100°C
|
SEV, CE, DNV, EAC, VDE
|
Version A acc. to EN 62444
|
5
|
CH
|
74199949
|
430 g
|
Max. clamping range depends on conduit inner diameter
|
|
||
Adapter EMC NPB, M63, long, ø41…46mm
Art:
1165.80.63.460
Copied
|
M63
|
M63
|
One-Piece
|
|
|
40 mm
|
46 mm
|
Cable gland IP 68
|
1.5
|
1.5 mm
|
14 mm
|
59 mm
|
70 mm
|
|
|
|
Nickel-plated brass
|
NBR
|
TPE
|
Nickel-plated brass
|
-40°C ... +100°C
|
SEV, CE, DNV, EAC, VDE
|
Version A acc. to EN 62444
|
5
|
CH
|
74199949
|
448 g
|
Max. clamping range depends on conduit inner diameter
|
|
||
Adapter EMC NPB, M50, long, ø37…41mm
Art:
1165.80.50.410
Copied
|
M50
|
M50
|
One-Piece
|
|
|
37 mm
|
41 mm
|
Cable gland IP 68
|
1.5
|
1.5 mm
|
14 mm
|
55 mm
|
55 mm
|
|
|
|
Nickel-plated brass
|
NBR
|
TPE
|
Nickel-plated brass
|
-40°C ... +100°C
|
SEV, CE, DNV, EAC, VDE
|
Version A acc. to EN 62444
|
5
|
CH
|
74199949
|
351.7 g
|
Max. clamping range depends on conduit inner diameter
|
|
||
Adapter EMC NPB, Pg 7, long, ø4…6mm
Art:
1165.80.07.060
Copied
|
PG 7
|
PG 7
|
One-Piece
|
|
|
4 mm
|
6 mm
|
Cable gland IP 68
|
|
|
10 mm
|
31 mm
|
15 mm
|
|
|
|
Nickel-plated brass
|
NBR
|
TPE
|
Nickel-plated brass
|
-40°C ... +100°C
|
EAC
|
|
50
|
CH
|
74199949
|
24.7 g
|
Max. clamping range depends on conduit inner diameter
|
|
||
Adapter EMC NPB, Pg 7, long, ø6…7.5mm
Art:
1165.80.07.075
Copied
|
PG 7
|
PG 7
|
One-Piece
|
|
|
6 mm
|
7.5 mm
|
Cable gland IP 68
|
|
|
10 mm
|
31 mm
|
15 mm
|
|
|
|
Nickel-plated brass
|
NBR
|
TPE
|
Nickel-plated brass
|
-40°C ... +100°C
|
EAC
|
|
50
|
CH
|
74199949
|
24.7 g
|
Max. clamping range depends on conduit inner diameter
|
|
||
Adapter EMC NPB, Pg 9, long, ø6…8mm
Art:
1165.80.09.080
Copied
|
PG 9
|
PG 9
|
One-Piece
|
|
|
6 mm
|
8 mm
|
Cable gland IP 68
|
|
|
10 mm
|
38 mm
|
18 mm
|
|
|
|
Nickel-plated brass
|
NBR
|
TPE
|
Nickel-plated brass
|
-40°C ... +100°C
|
EAC
|
|
50
|
CH
|
74199949
|
33.8 g
|
Max. clamping range depends on conduit inner diameter
|
|
||
Adapter EMC NPB, Pg 9, long, ø8…10mm
Art:
1165.80.09.100
Copied
|
PG 9
|
PG 9
|
One-Piece
|
|
|
8 mm
|
10 mm
|
Cable gland IP 68
|
|
|
10 mm
|
38 mm
|
18 mm
|
|
|
|
Nickel-plated brass
|
NBR
|
TPE
|
Nickel-plated brass
|
-40°C ... +100°C
|
EAC
|
|
50
|
CH
|
74199949
|
33.8 g
|
Max. clamping range depends on conduit inner diameter
|
|
||
Adapter EMC NPB, Pg 11, long, ø5.5…8.5mm
Art:
1165.80.11.085
Copied
|
PG 11
|
PG 11
|
One-Piece
|
|
|
5.5 mm
|
8.5 mm
|
Cable gland IP 68
|
|
|
10 mm
|
38 mm
|
21 mm
|
|
|
|
Nickel-plated brass
|
NBR
|
TPE
|
Nickel-plated brass
|
-40°C ... +100°C
|
EAC
|
|
50
|
CH
|
74199949
|
42 g
|
Max. clamping range depends on conduit inner diameter
|
|
||
Adapter EMC NPB, Pg 11, long, ø8.5…12mm
Art:
1165.80.11.120
Copied
|
PG 11
|
PG 11
|
One-Piece
|
|
|
8.5 mm
|
12 mm
|
Cable gland IP 68
|
|
|
10 mm
|
38 mm
|
21 mm
|
|
|
|
Nickel-plated brass
|
NBR
|
TPE
|
Nickel-plated brass
|
-40°C ... +100°C
|
EAC
|
|
50
|
CH
|
74199949
|
54.5 g
|
Max. clamping range depends on conduit inner diameter
|
|
||
Adapter EMC NPB, Pg 13, long, ø8…11mm
Art:
1165.80.13.110
Copied
|
PG 13
|
PG 13
|
One-Piece
|
|
|
8 mm
|
11 mm
|
Cable gland IP 68
|
|
|
10 mm
|
40 mm
|
24 mm
|
|
|
|
Nickel-plated brass
|
NBR
|
TPE
|
Nickel-plated brass
|
-40°C ... +100°C
|
EAC
|
|
25
|
CH
|
74199949
|
39.76 g
|
Max. clamping range depends on conduit inner diameter
|
|
||
Adapter EMC NPB, Pg 13, long, ø11…14mm
Art:
1165.80.13.140
Copied
|
PG 13
|
PG 13
|
One-Piece
|
|
|
11 mm
|
14 mm
|
Cable gland IP 68
|
|
|
10 mm
|
40 mm
|
24 mm
|
|
|
|
Nickel-plated brass
|
NBR
|
TPE
|
Nickel-plated brass
|
-40°C ... +100°C
|
EAC
|
|
25
|
CH
|
74199949
|
38 g
|
Max. clamping range depends on conduit inner diameter
|
|
||
Adapter EMC NPB, Pg 16, long, ø8…11mm
Art:
1165.80.16.110
Copied
|
PG 16
|
PG 16
|
One-Piece
|
|
|
8 mm
|
11 mm
|
Cable gland IP 68
|
|
|
10 mm
|
41 mm
|
24 mm
|
|
|
|
Nickel-plated brass
|
NBR
|
TPE
|
Nickel-plated brass
|
-40°C ... +100°C
|
EAC
|
|
25
|
CH
|
74199949
|
69.4 g
|
Max. clamping range depends on conduit inner diameter
|
|
||
Adapter EMC NPB, Pg 16, long, ø11…14mm
Art:
1165.80.16.140
Copied
|
PG 16
|
PG 16
|
One-Piece
|
|
|
11 mm
|
14 mm
|
Cable gland IP 68
|
|
|
10 mm
|
41 mm
|
24 mm
|
|
|
|
Nickel-plated brass
|
NBR
|
TPE
|
Nickel-plated brass
|
-40°C ... +100°C
|
EAC
|
|
25
|
CH
|
74199949
|
70.1 g
|
Max. clamping range depends on conduit inner diameter
|
|
||
Adapter EMC NPB, Pg 21, long, ø13…16mm
Art:
1165.80.21.160
Copied
|
PG 21
|
PG 21
|
One-Piece
|
|
|
13 mm
|
16 mm
|
Cable gland IP 68
|
|
|
12 mm
|
47 mm
|
30 mm
|
|
|
|
Nickel-plated brass
|
NBR
|
TPE
|
Nickel-plated brass
|
-40°C ... +100°C
|
EAC
|
|
10
|
CH
|
74199949
|
120.2 g
|
Max. clamping range depends on conduit inner diameter
|
|
||
Adapter EMC NPB, Pg 21, long, ø16…19mm
Art:
1165.80.21.190
Copied
|
PG 21
|
PG 21
|
One-Piece
|
|
|
16 mm
|
19 mm
|
Cable gland IP 68
|
|
|
12 mm
|
47 mm
|
30 mm
|
|
|
|
Nickel-plated brass
|
NBR
|
TPE
|
Nickel-plated brass
|
-40°C ... +100°C
|
EAC
|
|
10
|
CH
|
74199949
|
116.5 g
|
Max. clamping range depends on conduit inner diameter
|
|
||
Adapter EMC NPB, Pg 29, long, ø19…23mm
Art:
1165.80.29.230
Copied
|
PG 29
|
PG 29
|
One-Piece
|
|
|
19 mm
|
23 mm
|
Cable gland IP 68
|
|
|
12 mm
|
48 mm
|
40 mm
|
|
|
|
Nickel-plated brass
|
NBR
|
TPE
|
Nickel-plated brass
|
-40°C ... +100°C
|
EAC
|
|
10
|
CH
|
74199949
|
202.3 g
|
Max. clamping range depends on conduit inner diameter
|
|
||
Adapter EMC NPB, Pg 29, long, ø23…25.5mm
Art:
1165.80.29.255
Copied
|
PG 29
|
PG 29
|
One-Piece
|
|
|
23 mm
|
25.5 mm
|
Cable gland IP 68
|
|
|
12 mm
|
48 mm
|
40 mm
|
|
|
|
Nickel-plated brass
|
NBR
|
TPE
|
Nickel-plated brass
|
-40°C ... +100°C
|
EAC
|
|
10
|
CH
|
74199949
|
194.3 g
|
Max. clamping range depends on conduit inner diameter
|
|
||
Adapter EMC NPB, Pg 36, long, ø25…30.5mm
Art:
1165.80.36.305
Copied
|
PG 36
|
PG 36
|
One-Piece
|
|
|
25 mm
|
30.5 mm
|
Cable gland IP 68
|
|
|
15 mm
|
54 mm
|
50 mm
|
|
|
|
Nickel-plated brass
|
NBR
|
TPE
|
Nickel-plated brass
|
-40°C ... +100°C
|
EAC
|
|
10
|
CH
|
74199949
|
249 g
|
Max. clamping range depends on conduit inner diameter
|
|
||
Adapter EMC NPB, Pg 36, long, ø30.5…35mm
Art:
1165.80.36.350
Copied
|
PG 36
|
PG 36
|
One-Piece
|
|
|
30.5 mm
|
35 mm
|
Cable gland IP 68
|
|
|
15 mm
|
54 mm
|
50 mm
|
|
|
|
Nickel-plated brass
|
NBR
|
TPE
|
Nickel-plated brass
|
-40°C ... +100°C
|
EAC
|
|
10
|
CH
|
74199949
|
249 g
|
Max. clamping range depends on conduit inner diameter
|
|
||
Adapter EMC NPB, Pg 48, long, ø39…43mm
Art:
1165.80.48.430
Copied
|
PG 48
|
PG 48
|
One-Piece
|
|
|
39 mm
|
43 mm
|
Cable gland IP 68
|
|
|
15 mm
|
59 mm
|
65 mm
|
|
|
|
Nickel-plated brass
|
NBR
|
TPE
|
Nickel-plated brass
|
-40°C ... +100°C
|
EAC
|
|
5
|
CH
|
74199949
|
573.4 g
|
Max. clamping range depends on conduit inner diameter
|
|
||
Adapter EMC NPB, Pg 48, long, ø43…46.5mm
Art:
1165.80.48.465
Copied
|
PG 48
|
PG 48
|
One-Piece
|
|
|
43 mm
|
46.5 mm
|
Cable gland IP 68
|
|
|
15 mm
|
59 mm
|
65 mm
|
|
|
|
Nickel-plated brass
|
NBR
|
TPE
|
Nickel-plated brass
|
-40°C ... +100°C
|
EAC
|
|
5
|
CH
|
74199949
|
570.8 g
|
Max. clamping range depends on conduit inner diameter
|
|
||
PTFE-sealing for connectors US-P, ø10mm
Art:
5030.013.010
Copied
|
|
|
|
|
|
|
|
|
|
|
|
6 mm
|
|
13 mm
|
10.3 mm
|
10
|
PTFE
|
|
|
|
-60°C ... +300°C
|
|
|
50
|
|
|
|
|
|
||
PTFE-sealing for connectors US-P, ø14mm
Art:
5030.013.014
Copied
|
|
|
|
|
|
|
|
|
|
|
|
6 mm
|
|
17 mm
|
14.3 mm
|
14
|
PTFE
|
|
|
|
-60°C ... +300°C
|
|
|
50
|
|
|
|
|
|
||
PTFE-sealing for connectors US-P, ø19mm
Art:
5030.013.019
Copied
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
PTFE-sealing for connectors US-P, ø21mm
Art:
5030.013.021
Copied
|
|
|
|
|
|
|
|
|
|
|
|
7 mm
|
|
25 mm
|
21.3 mm
|
21
|
PTFE
|
|
|
|
-60°C ... +300°C
|
|
|
50
|
|
|
|
|
|
||
PTFE-sealing for connectors US-P, ø27mm
Art:
5030.013.027
Copied
|
|
|
|
|
|
|
|
|
|
|
|
9.5 mm
|
|
32 mm
|
27.4 mm
|
27
|
PTFE
|
|
|
|
-60°C ... +300°C
|
|
|
25
|
|
|
|
|
|
||
PTFE-sealing for connectors US-P, ø36mm
Art:
5030.013.036
Copied
|
|
|
|
|
|
|
|
|
|
|
|
9.5 mm
|
|
41 mm
|
36.4 mm
|
36
|
PTFE
|
|
|
|
-60°C ... +300°C
|
|
|
25
|
|
|
|
|
|
||
PTFE-sealing for connectors US-P, ø56mm
Art:
5030.013.056
Copied
|
|
|
|
|
|
|
|
|
|
|
|
9.5 mm
|
|
61 mm
|
56.5 mm
|
56
|
PTFE
|
|
|
|
-60°C ... +300°C
|
|
|
10
|
|
|
|
|
|
||
NPB, thrust collar for connectors, ø10mm
Art:
5031.034.007
Copied
|
|
|
|
|
|
|
|
|
|
|
|
5 mm
|
|
13 mm
|
10.2 mm
|
10
|
Nickel-plated brass
|
|
|
|
-40°C ... +250°C
|
|
|
50
|
CH
|
74199949
|
1.04 g
|
|
|
||
NPB, thrust collar for connectors, ø14mm
Art:
5031.034.009
Copied
|
|
|
|
|
|
|
|
|
|
|
|
5 mm
|
|
17 mm
|
14.5 mm
|
14
|
Nickel-plated brass
|
|
|
|
-40°C ... +250°C
|
|
|
50
|
CH
|
74199949
|
2.04 g
|
|
|
||
NPB, thrust collar for connectors, ø17mm
Art:
5031.034.011
Copied
|
|
|
|
|
|
|
|
|
|
|
|
5 mm
|
|
21 mm
|
17.2 mm
|
17
|
Nickel-plated brass
|
|
|
|
-40°C ... +250°C
|
|
|
50
|
CH
|
74199949
|
3.04 g
|
|
|
||
NPB, thrust collar for connectors, ø19mm
Art:
5031.034.013
Copied
|
|
|
|
|
|
|
|
|
|
|
|
6 mm
|
|
23 mm
|
19.2 mm
|
19
|
Nickel-plated brass
|
|
|
|
-40°C ... +250°C
|
|
|
50
|
CH
|
74199949
|
3.04 g
|
|
|
||
NPB, thrust collar for connectors, ø27mm
Art:
5031.034.021
Copied
|
|
|
|
|
|
|
|
|
|
|
|
8.5 mm
|
|
32 mm
|
27.3 mm
|
27
|
Nickel-plated brass
|
|
|
|
-40°C ... +250°C
|
|
|
25
|
CH
|
74199949
|
8.08 g
|
|
|
||
NPB, thrust collar for connectors, ø45mm
Art:
5031.034.036
Copied
|
|
|
|
|
|
|
|
|
|
|
|
8.5 mm
|
|
50 mm
|
45.3 mm
|
45
|
Nickel-plated brass
|
|
|
|
-40°C ... +250°C
|
|
|
20
|
CH
|
74199949
|
8.08 g
|
|
|
||
NPB, thrust collar for connectors, ø56mm
Art:
5031.034.048
Copied
|
|
|
|
|
|
|
|
|
|
|
|
8.5 mm
|
|
61 mm
|
56.3 mm
|
56
|
Nickel-plated brass
|
|
|
|
-40°C ... +250°C
|
|
|
10
|
CH
|
74199949
|
22.2 g
|
|
|
Select a variant in the list