ASCO

ASCO - 215 Series Direct Operated

2/2

  • Normally closed
  • Housing in aluminium
  • Working pressure 0 bar to 3.5 bar

Selected variant

Available in several variants

Selected variant

Technical data

General Data

Connection 3/8 BSP
Flow factor / flow coefficient 2,9
IP class IP65

Material Data

Material body Aluminium
Material of seals NBR
Material seat Aluminium

Temperature Data

Temperature of media from -20 °C
Temperature of media to 85 °C

Additional Data

Weight 0.6 kg
Power consumption 10.5 W
Throughput 19 mm
Type of valve Solenoid valve
Voltage AC 230 V
Temperature operational min -20 °C
Temperature operational max 75 °C
Material coil Epoxy
Differential air pressure max 3.5 bar
Differential pressure max 3.5 bar
Differential pressure min 0 bar
Flow max 48.3 l/min
Function 1 2/2
Function 2 Normally Closed
Material plunger Stainless steel
Material short-circuit ring Copper
Material glide ring PTFE
Material spring Stainless steel

Accessories

Related

water treatment plant tank- water and wastewater - OEM Automatic Solutions
Learning hub

Water & Wastewater Solutions

OEM Automatics water and wastewater application specialists have gathered all our solutions in one place. Our products are used in everything from small municipal water works to larger regional plants.

Selection of pumps - understanding velocity and why it matters when choosing a pump
Learning hub

understanding viscosity - And Why It Matters When Choosing A Pump

Whether you’re pumping water, chocolate, oil or peanut butter knowing the product’s viscosity is essential to selecting the right pump. Find out more about viscosity and which pump may be suitable for your application!

Tecnoplastic float switch
Product news

Float switches built to perform and ready to ship

Whether you're looking to upgrade your current solution or secure a more robust float switch for your next project, Taurus delivers performance you can count on.

groups of pressure switches and sensors with reservoir background - pressure sensors or switches
Learning hub

How do I know if I need a pressure switch or a pressure sensor?

When choosing between a pressure switch and a pressure sensor, the key lies in understanding your application. Our Pressure Monitoring experts breaks down the two devices for you.

SAMOA pumps
Product news

We offer air diaphragm pumps by SAMOA

Pumps are now officially part of our product offering! As we build our pump portfolio, we’re proud to announce that we are an official distributor of SAMOA Industrial, a well-established name in the fluid handling industry.

Barcode scanner technology: choosing the right technology for your application
Learning hub

Barcode Scanner Technology: Choosing The Right Technology For Your Application

OEM Automatic's barcode scanner experts have broken down barcode technology to help you choose the right scanner for your application!

Parts Connection Flow factor / flow coefficient Weight Power consumption Throughput Differential air pressure max Differential pressure max Flow max Price
3/8 BSP
2,9
0.6 kg
10.5 W
19 mm
3.5 bar
3.5 bar
48.3 l/min
1/2 BSP
3,8
0.6 kg
10.5 W
19 mm
3.5 bar
3.5 bar
63.3 l/min
3/4 BSP
4,4
0.7 kg
10.5 W
19 mm
3.5 bar
3.5 bar
73.3 l/min
G1
18
1.8 kg
15.4 W
41 mm
1.8 bar
1.8 bar
300 l/min
1 1/4 BSP
27
1.8 kg
15.4 W
41 mm
1.8 bar
1.8 bar
450 l/min
1 1/2 BSP
30
1.8 kg
15.4 W
41 mm
1.8 bar
1.8 bar
500 l/min
G2
50
2.1 kg
15.4 W
53 mm
1.8 bar
1.8 bar
833 l/min