• black icon of a bullhorn 30 years industry experience
  • black icon of three cubes Over 8,000 products in stock
  • Black icon of a clock Order by 16:00 and receive the next working day
SENSATA CRYDOM

SENSATA CRYDOM

CKR60 Series

  • Load current 10, 20, 30 A
  • Operating voltage 48-660 VAC
  • Control voltage 4-32 VDC, 110-280 VAC, 90-140 VAC, 18-36 VAC
  • Broad range of control voltage

Product description

Ratings from 10A to 30A @ 660 VAC - Slim 22.5mm (width) package - SCR output for heavy industrial loads - LED input status indicator - AC or DC control - zero voltage (resistive loads) or instantaneous turn on (inductive loads) output

  • Rating from 10A to 30A @ 660VAC
  • Slim 22.5mm (width) package
  • SCR output for heavy industrial loads
  • LED input status indicator
  • AC or DC control
  • Zero Voltage (resistive loads) or Instantaneous (inductive loads) turn-on output

 

Technical Data

Output Specifications (1)

Description

10A

20A

30A

Operating Voltage (47-63Hz) [Vrms]

48-660

48-660

48-660

Transient Overvoltage [Vpk]

1200

1200

1200

Maximum Off-State Leakage Current @ Rated Voltage [mArms]

1.0

1.0

1.0

Minimum Off-State dv/dt @ Maximum Rated Voltage [V/μsec] (2)

500

500

500

Maximum Load Current [Arms]

10

20

30

Minimum Load Current [Arms]

0.15

0.15

0.15

Maximum Surge Current (16.6ms) [Apk]

120

250

1200

Maximum On-State Voltage Drop @ Rated Current [Vpk]

1.6

1.6

1.6

Maximum I² t for Fusing (8.3 msec) [A² sec]

60

260

6000

Minimum Power Factor (with Maximum Load)

0.5

0.5

0.5

 

Input Specifications (1)

Description

CKRD60xx

CKRA60xx

CKRB60xx

CKRA60xxE

Control Voltage Range

4.0-32 VDC

110-280 Vrms

90-140 Vrms

18-36 Vrms

Minimum Turn-On Voltage

4.0 VDC

110 Vrms

90 Vrms

18 Vrms

Must Turn-Off Voltage

1.0 VDC

10 Vrms

10 Vrms

4.0 Vrms

Typical Input Current (4)

8-12 mA

5 mA @ 240 Vrms

5 mA @ 120 Vrms

10 mA @ 24 Vrms

Maximum Turn-On Time [msec] (3)

½ Cycle

10

10

10

Maximum Turn-Off Time [msec]

½ Cycle

40

40

40

 

General Specifications

Description

Parameters

Dielectric Strength, Input/Output/Base (50/60Hz)

4000 Vrms

Minimum Insulation Resistance (@ 500 V DC)

109 Ohms

Maximum Capacitance, Input/Output

8 pF

Ambient Operating Temperature Range

-40°C to 80°C

Ambient Storage Temperature Range

-40°C to 125°C

Status Indicator Display

Green LED

Weight (typical)

10 oz. (280g)

Encapsulation

Thermally Conductive Epoxy

Terminals

Box Clamp Type

Maximum Wire Size

AWG # 10 (3mm)

Recommended Terminal Screw Torque Range

5.0-6.0 in-lb (0.6-0.7 Nm)

Min. Side by Side Spacing

0.8 inch (20mm)

 

General Notes

1) All parameters at 25°C unless otherwise specified.

2) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1

3) Turn-on time for DC control instantaneous turn-on versions is 0.02 msec

4) Input circuitry for DC control version incorporates active current limiter.

 

Mechanical Specifications

 

Equivalent Circuit Block Diagram

AC Control

DC Control

 

Thermal Derate Information

 

Agency Approvals

Designed in accordance with the requirements of IEC 62314

E116950 LR81689 VDE 129156 Ce-markingRohs

Part Numbers

Product Selection

Control Voltage

10A

20A

30A

4-32 VDC Control

CKRD6010

CKRD6020

CKRD6030

110-280 VAC Control

CKRA6010

CKRA6020

CKRA6030

90-140 VAC Control

CKRB6010

CKRB6020

CKRB6030

18-36 VAC Control

CKRA6010E

CKRA6020E

CKRA6030E

 

Available Options

 

Number of variants matching filter 31/31 |

Part numbers

Parts Price Output current Type of control Additional features Control voltage
10 A Zero voltage turn on N/A 4-32V dc
10 A Instantaneous turn on N/A 4-32V dc
10 A Zero voltage turn on Overvoltage protection included 4-32V dc
20 A Zero voltage turn on N/A 4-32V dc
20 A Instantaneous turn on N/A 4-32V dc
20 A Zero voltage turn on Overvoltage protection included 4-32V dc
30 A Zero voltage turn on N/A 4-32V dc
30 A Instantaneous turn on N/A 4-32V dc
30 A Zero voltage turn on Overvoltage protection included 4-32V dc
30 A Instantaneous turn on Overvoltage protection included 4-32V dc
10 A Zero voltage turn on N/A 90-140V ac
10 A Instantaneous turn on N/A 90-140V ac
10 A Zero voltage turn on Overvoltage protection included 90-140V ac
20 A Zero voltage turn on N/A 90-140V ac
20 A Instantaneous turn on N/A 90-140V ac
20 A Zero voltage turn on Overvoltage protection included 90-140V ac
30 A Zero voltage turn on N/A 90-140V ac
30 A Instantaneous turn on N/A 90-140V ac
30 A Zero voltage turn on Overvoltage protection included 90-140V ac
30 A Zero voltage turn on N/A 110-280V ac
10 A Zero voltage turn on N/A 110-280V ac
10 A Instantaneous turn on N/A 110-280V ac
10 A Zero voltage turn on N/A 18-36V ac
10 A Zero voltage turn on Overvoltage protection included 110-280V ac
20 A Zero voltage turn on N/A 110-280V ac
20 A Instantaneous turn on N/A 110-280V ac
20 A Zero voltage turn on N/A 18-36V ac
20 A Zero voltage turn on Overvoltage protection included 110-280V ac
30 A Instantaneous turn on N/A 110-280V ac
30 A Zero voltage turn on N/A 18-36V ac
30 A Zero voltage turn on Overvoltage protection included 110-280V ac

Part

CKRD6010
DIN Rail SSR 22.5mm 660V ac 10A, 4.5-32V dc In, ZC

Technical data

Overview

Output current 10 A
Output voltage 48-660V ac
Control voltage 4-32V dc
Connection Screw connection
Type of control Zero voltage turn on
Additional features N/A

Output Specification

Output voltage 48-660V ac
Number of poles 1

Input Specification

Control voltage 4-32V dc

General Specification

Temperature operational min -40 °C
Temperature operational max 80 °C
Storage temperature max 125 °C
Storage temperature min -40 °C
Weight 280 g
Height 81,9 mm
Width 22,5 mm
Depth 99 mm

Measurements and connections

Technical illustrations

Contact us

If you need any help, you can contact us in one of the following ways:

0116 284 9900

Send an e-mail

Use live chat