Important notice - We will be performing system maintenance from 4pm Friday 19th April. Whilst we are performing this maintenance there will be no pricing available or ability to place orders. This will last for 2-3 days. Please contact customer support for any enquiries 0116 284 9900. We apologise for any inconvenience caused.
PULS
Puls Dimension Q is a series of power supplies with very small construction dimensions and many technical advantages.
The unit has low inrush current (even during warm start), active PFC, which provides a power factor close to one, extended temperature range, as well as active protection against mains transients.
Furthermore, there is a relay output (DC OK) that falls when the output voltage deviates more than 10% from the set value.
The bonus power provides 50% extra reserve with retained voltage which is an advantage when connected loads have high starting currents. The unit also provides a high short-circuit current that simplifies tripping of secondary fuses. Both the bonus power and short-circuit current is limited to 4 seconds to avoid constant overloading of the power supply and wiring.
High efficiency for long life and low temperature.
The power supply can be connected for two-phase operation Within up to +40°C. At higher temperatures, the load current is reduced.
Bonus power
The power supply has bonus power that enables high power outlet with retained 36 V DC for 4 seconds, which is a major advantage when connected loads have high starting currents, such as the case with motors. How often you can use the bonus effect depends on the application. With the following diagram and formula, the repeat time can be calculated for each application. The bonus power is available as soon as the power supply is started and directly after a short circuit.
Bonus power | Operating charcterisitcs | ||
Po | Nominal load current | ||
Ppeak | Peak current | ||
To | Time between bonus power | ||
Tpeak | Peak current in time | ||
Operating cycle | Tpeak / (Tpeak + To) | ||
To | Tpeak - (operating cycle * Tpeak) / operating cycle | ||
E.g. Nominal load current (Po) is 6.6 A, Po = 50% of In. Peak current (Ppeak) is 16A = 120%. Peak time is 3 seconds. Draw a vertical line at 120% of duty cycle, where the line crosses the Po = 50% horisontel draw a line to the duty cycle value. In this case, the value is about 0.68. 3- (3x0,68) / 0.68 = 1.41. In this example, one can repeat the bonus effect with a gap of 1.41 seconds. |
Input data |
|
---|---|
Input voltage ac | 380-480 V |
Input voltage ac min | 323 V AC |
Input voltage ac max | 552 V AC |
Inrush current at 400 V ac typical | 3 A |
Input voltage range | Wide-range |
Power factor at 400 V ac, full load. Typical | 0,94 |
Number of phases | 3 |
Output data |
|
Output voltage | 36 V DC |
Output voltage min | 36 V DC |
Output voltage max | 42 V DC |
Output current | 13,3 A |
Power | 480 W |
Efficiency / Lifetime / MTBF |
|
Efficiency at 400 V ac, typical | 94 % |
Efficiency at 400 V ac, full load, typical | 94,8 % |
Lifetime at 400 V ac, full load and +40 ° C | 51000 h |
MTBF (IEC 61709) 400 V ac, max loan, +40 °C | 690000 h |
Dimensions |
|
Width | 65 mm |
Height | 124 mm |
*Invisible Heading* |
|
---|---|
Depth | 127 mm |
Weight | 0,87 kg |
Other |
|
Approvals | CB, CE, CSA US, cRUus, cULus, GL |
Hold time at 400 V ac, typical full load | 22 ms |
IP class | IP20 |
Clamp type | Spring-clamp |
Material protection | Aluminium |
Supply frequency | 50-60 ±6 % |
Ripple max | 100 mV pp |
Series | Dimension Q |
Power consumption at 400 V ac | 0,79 A |
Power drop from +60 °C to + 70 °C | 12 W/°C |
Temperature min without derating | -25 °C |
Temperature max without derating | 60 °C |
Type Power Supply | AC-DC |
DC relay output | Yes |
Active Transient | Yes |
Puls Dimension Q is a series of power supplies with very small construction dimensions and many technical advantages.
The unit has low inrush current (even during warm start), active PFC, which provides a power factor close to one, extended temperature range, as well as active protection against mains transients.
Furthermore, there is a relay output (DC OK) that falls when the output voltage deviates more than 10% from the set value.
The bonus power provides 50% extra reserve with retained voltage which is an advantage when connected loads have high starting currents. The unit also provides a high short-circuit current that simplifies tripping of secondary fuses. Both the bonus power and short-circuit current is limited to 4 seconds to avoid constant overloading of the power supply and wiring.
High efficiency for long life and low temperature.
The power supply can be connected for two-phase operation Within up to +40°C. At higher temperatures, the load current is reduced.
Bonus power
The power supply has bonus power that enables high power outlet with retained 36 V DC for 4 seconds, which is a major advantage when connected loads have high starting currents, such as the case with motors. How often you can use the bonus effect depends on the application. With the following diagram and formula, the repeat time can be calculated for each application. The bonus power is available as soon as the power supply is started and directly after a short circuit.
Bonus power | Operating charcterisitcs | ||
Po | Nominal load current | ||
Ppeak | Peak current | ||
To | Time between bonus power | ||
Tpeak | Peak current in time | ||
Operating cycle | Tpeak / (Tpeak + To) | ||
To | Tpeak - (operating cycle * Tpeak) / operating cycle | ||
E.g. Nominal load current (Po) is 6.6 A, Po = 50% of In. Peak current (Ppeak) is 16A = 120%. Peak time is 3 seconds. Draw a vertical line at 120% of duty cycle, where the line crosses the Po = 50% horisontel draw a line to the duty cycle value. In this case, the value is about 0.68. 3- (3x0,68) / 0.68 = 1.41. In this example, one can repeat the bonus effect with a gap of 1.41 seconds. |
Renowned for high-quality cable cutting and crimping tools, Klauke serves electrical contractors, cable jointers, and linemen across a spectrum of sectors
At OEM Automatic, we can supply a series of components for your one project. All under one roof. This case study discusses how we supplied several components for our customer's new electro-pneumatic control box.
To promote constant and reliable performance, as well as a longer life of parts in the vehicle, it is important to consider the right cable protector.
We have now added switch disconnectors to our range! Switch disconnectors contribute to the overall functionality and safety of electrical systems.
LOCC-Box from Lutze is an intelligent current monitoring device that provides reliable protection of DC circuits in a slimline 8.1mm housing.
OEM Automatic has integrated push-in technology into it's product offering for many years now. In this blog post, we'll explore the various benefits of push-in technology and some of the products we offer that make use of this innovation, such as push-in terminals, push-in sockets, and even push-in heaters.
|
|
|
|
|
||
---|---|---|---|---|---|---|
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
Parts | Price | ||
---|---|---|---|
PSU 3PH 380-480V ac I/P 36V dc 13.3A 480W O/P
Art:
QT20.361
Copied
|
|
Select a variant in the list
If you need any help, you can contact us in one of the following ways: