CROUZET CONTROL
NOW OBSOLETE WITH NO SUGGESTED REPLACEMENT
This unit is used for level control using floats (input/output sensors). When power is connected, the relay remains in standby mode and level control does not begin until the push button is pressed. This button is on the front but can also be connected between Y1 and A1 for an external button.
The output relay only activates if the input/output sensor opens. If the level is raised so that the sensor closes, the relay drops out after the set time delay (Toff). When the level drops and the sensor opens again, the relay is reactivated after the time delay (Ton). The LEDs flash when the power is connected to the unit due to the cycle having not started yet (the push button has not been pressed). The time delays Ton and Toff are set between 1 and 10 s. using two potentiometers on the front. Green LED (Un) indicates supply voltage OK. Yellow LED (R) indicates active relay output.
Approvals | CE, CSA, GL, RoHS, UL |
---|---|
Breaking capacity | 5A, 250V AC/DC |
IP class connection | IP20 |
IP class housing | IP30 |
Storage temperature max | 70 °C |
Storage temperature min | -40 °C |
Supply voltage ac/dc max | 264 V |
Supply voltage ac/dc min | 20.4 V |
---|---|
Temperature operational max | 50 °C |
Temperature operational min | -20 °C |
Time range | 1-10s, separat inställbart för till- och frånslag |
Weight | 80 g |
NOW OBSOLETE WITH NO SUGGESTED REPLACEMENT
This unit is used for level control using floats (input/output sensors). When power is connected, the relay remains in standby mode and level control does not begin until the push button is pressed. This button is on the front but can also be connected between Y1 and A1 for an external button.
The output relay only activates if the input/output sensor opens. If the level is raised so that the sensor closes, the relay drops out after the set time delay (Toff). When the level drops and the sensor opens again, the relay is reactivated after the time delay (Ton). The LEDs flash when the power is connected to the unit due to the cycle having not started yet (the push button has not been pressed). The time delays Ton and Toff are set between 1 and 10 s. using two potentiometers on the front. Green LED (Un) indicates supply voltage OK. Yellow LED (R) indicates active relay output.
This innovative push-in connection system enables time savings of up to 50%, whether you're wiring control panels or managing complex installations
Solar energy has become a pillar of the global energy transition. The experts at OEM Automatic have broken down the role of photovoltaic fuses and their contribution to solar systems, as well as, how to choose the right solution for you.
Ultra fast-acting fuse links engineered specifically to shield delicate semiconductor devices.
Do you need reliable protection for measuring and control equipment? DEHN YellowLine delivers voltage surge protection tailored for building, measuring, and control systems
Choosing the right circuit breaker is important for protecting DC circuits. Two primary forms of protection are MCBs and ECBs. The experts at OEM Automatic breakdown the two circuit breakers for you!
New signal lights from Auer Signal are now available! The first products to be launched in this series are the Smart Dot 50 in the Basic and Standard versions, as well as the Smart Indicator 50 in the Basic version.