Important notice - We will be performing system maintenance from 4pm Friday 19th April. Whilst we are performing this maintenance there will be no pricing available or ability to place orders. This will last for 2-3 days. Please contact customer support for any enquiries 0116 284 9900. We apologise for any inconvenience caused.
CROUZET CONTROL
HIL and HIH control relays are used for monitoring 1-phase AC/DC currents. The relay automatically detects the form of current that is to be measured. The relay requires a supply voltage. Using a rotary switch, selection can be made between over- or under-current, with or without memory.If “with memory” is selected, the supply voltage to the relay must be switched off to restart. The switch position and consequently the control relay's function mode is detected when the operating voltage is switched on. If the switch is in the wrong position, the relay will remain deactivated and the LEDs will flash to indicate incorrect setting. If the switch position is changed during operation, all LEDs begin to flash but the unit will continue to function normally with the function that was set at the most recent power connection. The LEDs return to normal function when the switch has been returned to its original position, which was set before the first power connection. The limit value for over- and under-current is set with a potentiometer that is scaled in the percentage of the current range that is to be monitored. The hysteresis value is similarly set with a scale from 5-50 % of the set limit value. The hysteresis value cannot exceed the measurement range's limit value. Both relays are equipped with a time delay (Tt) to ignore temporary current deviations. HIL and HIH also have a time delay upon start-up (Tt), adjustable between 1-20 s to avoid current peaks or current dips upon start-up. If the current should exceed 10 A, a current transformer can be used. Green LED (Un) indicates supply voltage OK. Yellow LED (R) indicates active relay output.
Adjustable limit value from | 10 % |
---|---|
Adjustable limit value to | 100 % |
Approvals | CE, CSA, RoHS, UL |
Breaking capacity | 5A, 250V AC/DC |
E1-M max. continuous current in 25°C | 2 A |
E1-M max. current <1s at 25°C | 17 A |
E2-M max. continuous current in 25°C | 11 A |
E2-M max. current <1s at 25°C | 20 A |
E3-M max. continuous current in 25°C | 11 A |
E3-M max. current <1s at 25°C | 50 A |
Function | Over/Undercurrent |
IP class connection | IP20 |
IP class housing | IP30 |
Measurement range E1-M | 0,1-1A |
Measurement range E2-M | 0,5-5A |
---|---|
Measurement range E3-M | 1-10A |
Mounting | DIN rail |
Output | Relay 2 pole C/O |
Storage temperature max | 70 °C |
Storage temperature min | -30 °C |
Supply voltage | 24-240V ac/dc |
Temperature operational max | 50 °C |
Temperature operational min | -20 °C |
Time delay startup | 1-20s |
Time delay when exceeding the limit value | 0,1-3s |
Weight | 130 g |
With memory
1: Limit value
2: Hysteresis
3: Over-current
4: Under-current
5: Activation of operating voltage
6: Monitored current
7: Time delay, start-up (Ti)
8: Time delay upon exceeding limit value (Tt)
Without memory
1: Limit value
2: Hysteresis
3: Over-current
4: Under-current
5: Activation of operating voltage
6: Monitored current
7: Time delay, start-up (Ti)
8: Time delay upon exceeding limit value (Tt)
HIL and HIH control relays are used for monitoring 1-phase AC/DC currents. The relay automatically detects the form of current that is to be measured. The relay requires a supply voltage. Using a rotary switch, selection can be made between over- or under-current, with or without memory.If “with memory” is selected, the supply voltage to the relay must be switched off to restart. The switch position and consequently the control relay's function mode is detected when the operating voltage is switched on. If the switch is in the wrong position, the relay will remain deactivated and the LEDs will flash to indicate incorrect setting. If the switch position is changed during operation, all LEDs begin to flash but the unit will continue to function normally with the function that was set at the most recent power connection. The LEDs return to normal function when the switch has been returned to its original position, which was set before the first power connection. The limit value for over- and under-current is set with a potentiometer that is scaled in the percentage of the current range that is to be monitored. The hysteresis value is similarly set with a scale from 5-50 % of the set limit value. The hysteresis value cannot exceed the measurement range's limit value. Both relays are equipped with a time delay (Tt) to ignore temporary current deviations. HIL and HIH also have a time delay upon start-up (Tt), adjustable between 1-20 s to avoid current peaks or current dips upon start-up. If the current should exceed 10 A, a current transformer can be used. Green LED (Un) indicates supply voltage OK. Yellow LED (R) indicates active relay output.
Renowned for high-quality cable cutting and crimping tools, Klauke serves electrical contractors, cable jointers, and linemen across a spectrum of sectors
At OEM Automatic, we can supply a series of components for your one project. All under one roof. This case study discusses how we supplied several components for our customer's new electro-pneumatic control box.
To promote constant and reliable performance, as well as a longer life of parts in the vehicle, it is important to consider the right cable protector.
We have now added switch disconnectors to our range! Switch disconnectors contribute to the overall functionality and safety of electrical systems.
LOCC-Box from Lutze is an intelligent current monitoring device that provides reliable protection of DC circuits in a slimline 8.1mm housing.
OEM Automatic has integrated push-in technology into it's product offering for many years now. In this blog post, we'll explore the various benefits of push-in technology and some of the products we offer that make use of this innovation, such as push-in terminals, push-in sockets, and even push-in heaters.
|
|
|
|
|
||
---|---|---|---|---|---|---|
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
Parts | E1-M max. continuous current in 25°C | E1-M max. current <1s at 25°C | E2-M max. continuous current in 25°C | E2-M max. current <1s at 25°C | E3-M max. continuous current in 25°C | E3-M max. current <1s at 25°C | Measurement range E1-M | Measurement range E2-M | Measurement range E3-M | Price | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Current Monitor Relay HIH 24-240V ac/dc
Art:
84871130
Copied
|
2 A
|
17 A
|
11 A
|
20 A
|
11 A
|
50 A
|
0,1-1A
|
0,5-5A
|
1-10A
|
| ||
Current Monitor Relay HIL 24-240V ac/dc
Art:
84871120
Copied
|
0,4 A
|
1 A
|
1 A
|
5 A
|
2 A
|
8 A
|
2-20mA
|
10-100mA
|
50-500mA
|
|