CONTA-CLIP
The FNT neutral disconnect terminals feature an integral mounting post for attaching the 10x3-mm neutral busbar.
No additional plates or fixings are required, Â as a secure contact to the busbar is made using the
no-screw slider for the neutral conductor.
With the FSLI protective earth terminals, the PE potential is connected via the PE foot (which contacts the DIN rail on both sides).
Solid wires and flexible wires with wire-end ferrules can be inserted into the connection mechanism without the need for tools.
The pressure spring opens automatically when the wire is inserted; this ensures a secure contact with the busbar.
A standard screwdriver can be used to open the clamp for release and for the insertion of stranded wire without ferrules.
This range can also be combined with the FDLIS three-level installation terminal range.
The one-level terminals – FRKI, FSLI, and FNT – can be used in combination with the three-level FDLIS installation terminals, as the height of the neutral busbar is identical in both versions.
Where the neutral busbar is not being used with the 16mm terminals, there is the FRK16 in the standard range, this has a central din rail mounting foot and provides a symmetrical layout.
Â
General data |
|
---|---|
Rated wire cross section | 4 mm² |
Colour | Beige |
Rated voltage IEC | 800 V |
Rated current IEC | 32 A |
Mounting | TS 35 |
Rated impulse voltage | 8 kV |
Overvoltage category | III |
Contamination degree | 3 |
Approvals | CSA, CSA US, KEMA KUR, EAC |
Dimensions |
|
Length | 52,5 mm |
Width | 5,1 mm |
Height TS 35/7.5 | 38,5 mm |
Height | 37,5 mm |
Connection data |
|
Connections | 2 |
Number of levels | 1 |
Plug gauge acc. EN 60 947-1 | A4 |
Cross connect channels | 2 |
Cross section single wire from | 0,5 mm² |
Cross section single wire to | 6 mm² |
Cross section stranded wire from | 0,6 mm² |
Cross section stranded wire to | 6 mm² |
Cross section stranded with ferrule from | 0,5 mm² |
*Invisible Heading* |
|
---|---|
Cross section stranded with ferrule to | 4 mm² |
Rated wire cross section from (AWG) | 20 |
Rated wire cross section to (AWG) | 10 |
Stripping length | 12 mm |
Materials |
|
Insulation material | Polyamide 6.6 |
Flammability class | UL94-V0 |
Operating temperature from | -40 °C |
Operating temperature to | 120 °C |
Approvals |
|
Rated voltage CSA | 600 V |
Rated current CSA | 28 A |
CSA test standard | C22.2 No 158 |
Rated voltage CSAus | 600 V |
Rated current CSAus | 28 A |
CSAus test standard | UL 1059 |
EAC test standard | TR ZU 004/2011 |
KEMA KEUR test standard | EN 60947-7-1:2009 |
Additional data |
|
Tariff code | 85369010 |
Country of origin | BG |
Weight | 8,25 g |
Pack size | 100 |
The FNT neutral disconnect terminals feature an integral mounting post for attaching the 10x3-mm neutral busbar.
No additional plates or fixings are required, Â as a secure contact to the busbar is made using the
no-screw slider for the neutral conductor.
With the FSLI protective earth terminals, the PE potential is connected via the PE foot (which contacts the DIN rail on both sides).
Solid wires and flexible wires with wire-end ferrules can be inserted into the connection mechanism without the need for tools.
The pressure spring opens automatically when the wire is inserted; this ensures a secure contact with the busbar.
A standard screwdriver can be used to open the clamp for release and for the insertion of stranded wire without ferrules.
This range can also be combined with the FDLIS three-level installation terminal range.
The one-level terminals – FRKI, FSLI, and FNT – can be used in combination with the three-level FDLIS installation terminals, as the height of the neutral busbar is identical in both versions.
Where the neutral busbar is not being used with the 16mm terminals, there is the FRK16 in the standard range, this has a central din rail mounting foot and provides a symmetrical layout.
Â
The smallest logic controller by Crouzet is now 20% off for a limited time only! A powerhouse packed into just 17.5mm! Efficiency, adaptability, and seamless integration with free software.
Do you require signalling devices and beacons in your production process? Download our latest whitepaper!
Here, our customer requires control boxes for electricity metering systems. We leveraged our expertise to deliver easy-to-install, ready-to-use assemblies. We look forward to creating more of these bespoke control boxes for our customer.
This blog talks all things DC circuit protection including the key components: electronic circuit breakers, fuses and current monitoring devices. As well as how to choose the right protection.
Did you get a chance to visit IATECH at The Leicester Marriott Hotel? We had over 33 exhibitors and 8 fantastic Tech Talks throughout the day, Read all about the day, here.
To help experience the capabilities of Z+F machines first-hand, we provide an in-depth demonstration and workshop. These sessions will show the machines in action and allow you to understand their features and gain valuable insight into their operation and benefits.
|
|
|
|
|
||
---|---|---|---|---|---|---|
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
Parts | Rated wire cross section | Colour | Rated voltage IEC | Rated current IEC | Rated impulse voltage | Approvals | Length | Width | Height TS 35/7.5 | Height | Connections | Plug gauge acc. EN 60 947-1 | Cross connect channels | Cross section single wire from | Cross section single wire to | Cross section stranded wire from | Cross section stranded wire to | Cross section stranded with ferrule from | Cross section stranded with ferrule to | Rated wire cross section from (AWG) | Rated wire cross section to (AWG) | Stripping length | Rated voltage UL | Rated current UL | UL test standard | Rated voltage CSA | Rated current CSA | CSA test standard | Rated voltage CSAus | Rated current CSAus | CSAus test standard | Rated voltage cUL | Rated current cUL | cUL test standard | EAC test standard | KEMA KEUR test standard | Country of origin | Weight | Pack size | Price | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]()
FRKI 2.5-4 Beige, 4mm² Installation feed through, push-in
Art:
3276.2
Copied
|
4 mm²
|
Beige
|
800 V
|
32 A
|
8 kV
|
CSA, CSA US, KEMA KUR, EAC
|
52,5 mm
|
5,1 mm
|
38,5 mm
|
37,5 mm
|
2
|
A4
|
2
|
0,5 mm²
|
6 mm²
|
0,6 mm²
|
6 mm²
|
0,5 mm²
|
4 mm²
|
20
|
10
|
12 mm
|
|
|
|
600 V
|
28 A
|
C22.2 No 158
|
600 V
|
28 A
|
UL 1059
|
|
|
|
TR ZU 004/2011
|
EN 60947-7-1:2009
|
BG
|
8,25 g
|
100
|
| ||
![]()
FRKI 2.5-4 Blue, 4mm² Installation feed through, push-in
Art:
3276.5
Copied
|
4 mm²
|
Blue
|
800 V
|
32 A
|
8 kV
|
CSA, CSA US, KEMA KUR, EAC
|
52,5 mm
|
5,1 mm
|
38,5 mm
|
37,5 mm
|
2
|
A4
|
2
|
0,5 mm²
|
6 mm²
|
0,6 mm²
|
6 mm²
|
0,5 mm²
|
4 mm²
|
20
|
10
|
12 mm
|
|
|
|
600 V
|
28 A
|
C22.2 No 158
|
600 V
|
28 A
|
UL 1059
|
|
|
|
TR ZU 004/2011
|
EN 60947-7-1:2009
|
BG
|
8,25 g
|
100
|
| ||
![]()
FRKI 2.5-4 Orange, 4mm² Installation feed through, push-in
Art:
3276.3
Copied
|
4 mm²
|
Orange
|
800 V
|
32 A
|
8 kV
|
CSA, CSA US, KEMA KUR, EAC
|
52,5 mm
|
5,1 mm
|
38,5 mm
|
37,5 mm
|
2
|
A4
|
2
|
0,5 mm²
|
6 mm²
|
0,6 mm²
|
6 mm²
|
0,5 mm²
|
4 mm²
|
20
|
10
|
12 mm
|
|
|
|
600 V
|
28 A
|
C22.2 No 158
|
600 V
|
28 A
|
UL 1059
|
|
|
|
TR ZU 004/2011
|
EN 60947-7-1:2009
|
BG
|
8,25 g
|
100
|
| ||
![]()
FSLI 2,5-4 GNYE
Art:
3279.2
Copied
|
4 mm²
|
Green/yellow
|
|
|
|
CSA, CSA US, KEMA KUR, EAC
|
52,5 mm
|
5,1 mm
|
38,5 mm
|
37,5 mm
|
2
|
A4
|
1
|
0,5 mm²
|
6 mm²
|
0,6 mm²
|
6 mm²
|
0,5 mm²
|
4 mm²
|
20
|
10
|
12 mm
|
|
|
|
|
|
C22.2 No 158
|
|
|
UL 1059
|
|
|
|
TR ZU 004/2011
|
EN 60947-7-2:2009
|
BG
|
11,25 g
|
100
|
| ||
![]()
FNT 2,5-4 BU
Art:
3273.5
Copied
|
4 mm²
|
Blue
|
250 V
|
32 A
|
8 kV
|
KEMA KUR
|
64 mm
|
5,1 mm
|
42,5 mm
|
41,5 mm
|
1
|
A4
|
1
|
0,5 mm²
|
6 mm²
|
0,6 mm²
|
6 mm²
|
0,5 mm²
|
4 mm²
|
20
|
10
|
12 mm
|
|
|
|
|
|
|
|
|
|
|
|
|
|
EN 60947-7-1:2009
|
BG
|
9,25 g
|
100
|
| ||
![]()
FRKI 6-10 Beige, 10mm² Installation feed through, push-in
Art:
3277.2
Copied
|
10 mm²
|
Beige
|
800 V
|
57 A
|
8 kV
|
CSA, CSA US, KEMA KUR, EAC
|
56,5 mm
|
8,1 mm
|
40,5 mm
|
39,8 mm
|
2
|
A5
|
2
|
1,5 mm²
|
10 mm²
|
1,5 mm²
|
10 mm²
|
1,5 mm²
|
10 mm²
|
22
|
10
|
12 mm
|
|
|
|
600 V
|
44 A
|
C22.2 No 158
|
600 V
|
44 A
|
UL 1059
|
|
|
|
TR ZU 004/2011
|
EN 60947-7-1:2009
|
BG
|
14,25 g
|
100
|
| ||
![]()
FRKI 6-10 Blue, 10mm² Installation feed through, push-in
Art:
3277.5
Copied
|
10 mm²
|
Blue
|
800 V
|
57 A
|
8 kV
|
CSA, CSA US, KEMA KUR, EAC
|
56,5 mm
|
8,1 mm
|
40,5 mm
|
39,8 mm
|
2
|
A5
|
2
|
1,5 mm²
|
10 mm²
|
1,5 mm²
|
10 mm²
|
1,5 mm²
|
10 mm²
|
22
|
10
|
12 mm
|
|
|
|
600 V
|
44 A
|
C22.2 No 158
|
600 V
|
44 A
|
UL 1059
|
|
|
|
TR ZU 004/2011
|
EN 60947-7-1:2009
|
BG
|
14,25 g
|
100
|
| ||
![]()
FRKI 6-10 Orange, 10mm² Installation feed through, push-in
Art:
3277.3
Copied
|
10 mm²
|
Orange
|
800 V
|
57 A
|
8 kV
|
CSA, CSA US, KEMA KUR, EAC
|
56,5 mm
|
8,1 mm
|
40,5 mm
|
39,8 mm
|
2
|
A5
|
2
|
1,5 mm²
|
10 mm²
|
1,5 mm²
|
10 mm²
|
1,5 mm²
|
10 mm²
|
22
|
10
|
12 mm
|
|
|
|
600 V
|
44 A
|
C22.2 No 158
|
600 V
|
44 A
|
UL 1059
|
|
|
|
TR ZU 004/2011
|
EN 60947-7-1:2009
|
BG
|
14,25 g
|
100
|
| ||
![]()
FRKI 6-10 RD
Art:
3277.9
Copied
|
10 mm²
|
Red
|
800 V
|
57 A
|
8 kV
|
CSA, CSA US, KEMA KUR, EAC
|
56,5 mm
|
8,1 mm
|
40,5 mm
|
39,8 mm
|
2
|
A5
|
2
|
1,5 mm²
|
10 mm²
|
1,5 mm²
|
10 mm²
|
1,5 mm²
|
10 mm²
|
22
|
10
|
12 mm
|
|
|
|
600 V
|
44 A
|
C22.2 No 158
|
600 V
|
44 A
|
UL 1059
|
|
|
|
TR ZU 004/2011
|
EN 60947-7-1:2009
|
CZ
|
14,25 g
|
100
|
| ||
![]()
FSLI 6-10 GNYE
Art:
3280.2
Copied
|
10 mm²
|
Green/yellow
|
|
|
|
CSA, CSA US, KEMA KUR, EAC
|
56,5 mm
|
8,1 mm
|
40,5 mm
|
39,8 mm
|
2
|
A5
|
1
|
1,5 mm²
|
10 mm²
|
1,5 mm²
|
10 mm²
|
1,5 mm²
|
10 mm²
|
22
|
10
|
12 mm
|
|
|
|
|
|
C22.2 No 158
|
|
|
UL 1059
|
|
|
|
TR ZU 004/2011
|
EN 60947-7-2:2009
|
BG
|
20,25 g
|
100
|
| ||
![]()
FNT 6-10 BU
Art:
3274.5
Copied
|
10 mm²
|
Blue
|
250 V
|
57 A
|
8 kV
|
KEMA KUR
|
67,5 mm
|
8,1 mm
|
40,5 mm
|
39,8 mm
|
1
|
A5
|
1
|
1,5 mm²
|
10 mm²
|
1,5 mm²
|
10 mm²
|
1,5 mm²
|
10 mm²
|
22
|
10
|
12 mm
|
|
|
|
|
|
|
|
|
|
|
|
|
|
EN 60947-7-1:2009
|
BG
|
16,25 g
|
100
|
| ||
![]()
FRKI 6-10/3A BG
Art:
3216.2
Copied
|
10 mm²
|
Beige
|
800 V
|
57 A
|
8 kV
|
EAC
|
82,4 mm
|
8,1 mm
|
39,8 mm
|
|
3
|
A3
|
2
|
1,5 mm²
|
10 mm²
|
1,5 mm²
|
10 mm²
|
1,5 mm²
|
10 mm²
|
16
|
8
|
12 mm
|
600 V
|
44 A
|
UL 1059
|
|
|
|
|
|
|
44 V
|
600 A
|
C22.2 No 158
|
TR ZU 004/2011
|
EN 60947-7-1:2009
|
BG
|
27,09 g
|
50
|
| ||
![]()
FRKI 6-10/3A BU
Art:
3216.5
Copied
|
10 mm²
|
Blue
|
800 V
|
57 A
|
8 kV
|
EAC
|
82,4 mm
|
8,1 mm
|
39,8 mm
|
|
3
|
A3
|
2
|
1,5 mm²
|
10 mm²
|
1,5 mm²
|
10 mm²
|
1,5 mm²
|
10 mm²
|
16
|
8
|
12 mm
|
600 V
|
44 A
|
UL 1059
|
|
|
|
|
|
|
44 V
|
600 A
|
C22.2 No 158
|
TR ZU 004/2011
|
EN 60947-7-1:2009
|
BG
|
27,09 g
|
50
|
| ||
![]()
FRKI 6-10/3A OG
Art:
3216.3
Copied
|
10 mm²
|
Orange
|
800 V
|
57 A
|
8 kV
|
EAC
|
82,4 mm
|
8,1 mm
|
39,8 mm
|
|
3
|
A3
|
2
|
1,5 mm²
|
10 mm²
|
1,5 mm²
|
10 mm²
|
1,5 mm²
|
10 mm²
|
16
|
8
|
12 mm
|
600 V
|
44 A
|
UL 1059
|
|
|
|
|
|
|
44 V
|
600 A
|
C22.2 No 158
|
TR ZU 004/2011
|
EN 60947-7-1:2009
|
BG
|
27,09 g
|
50
|
| ||
![]()
FSLI 6-10/3A GNYE
Art:
3217.2
Copied
|
10 mm²
|
Green/yellow
|
|
|
|
EAC
|
82,4 mm
|
8,1 mm
|
39,8 mm
|
|
3
|
A3
|
2
|
1,5 mm²
|
10 mm²
|
1,5 mm²
|
10 mm²
|
1,5 mm²
|
10 mm²
|
16
|
8
|
12 mm
|
|
|
UL 1059
|
|
|
|
|
|
|
|
|
C22.2 No 158
|
TR ZU 004/2011
|
EN 60947-7-2:2009
|
BG
|
33,87 g
|
50
|
| ||
![]()
FRKI 16/2A BG
Art:
3278.2
Copied
|
16 mm²
|
Beige
|
1000 V
|
76 A
|
8 kV
|
EAC
|
72,4 mm
|
12,1 mm
|
49 mm
|
48 mm
|
2
|
A7
|
2
|
2,5 mm²
|
25 mm²
|
2,5 mm²
|
25 mm²
|
2,5 mm²
|
16 mm²
|
14
|
4
|
18 mm
|
600 V
|
75 A
|
UL 1059
|
|
|
|
|
|
|
75 V
|
600 A
|
C22.2 No 158
|
TR ZU 004/2011
|
EN 60947-7-1:2009
|
CZ
|
17,8 g
|
50
|
| ||
![]()
FRKI 16/2A BU
Art:
3278.5
Copied
|
16 mm²
|
Blue
|
1000 V
|
76 A
|
8 kV
|
EAC
|
72,4 mm
|
12,1 mm
|
49 mm
|
48 mm
|
2
|
A7
|
2
|
2,5 mm²
|
25 mm²
|
2,5 mm²
|
25 mm²
|
2,5 mm²
|
16 mm²
|
14
|
4
|
18 mm
|
600 V
|
75 A
|
UL 1059
|
|
|
|
|
|
|
75 V
|
600 A
|
C22.2 No 158
|
TR ZU 004/2011
|
EN 60947-7-1:2009
|
CZ
|
17,8 g
|
50
|
| ||
FRKI 16/2A OG
Art:
3278.3
Copied
|
16 mm²
|
Orange
|
1000 V
|
76 A
|
8 kV
|
EAC
|
72,4 mm
|
12,1 mm
|
49 mm
|
48 mm
|
2
|
A7
|
2
|
2,5 mm²
|
25 mm²
|
2,5 mm²
|
25 mm²
|
2,5 mm²
|
16 mm²
|
14
|
4
|
18 mm
|
600 V
|
75 A
|
UL 1059
|
|
|
|
|
|
|
75 V
|
600 A
|
C22.2 No 158
|
TR ZU 004/2011
|
EN 60947-7-1:2009
|
CZ
|
17,8 g
|
50
|
| ||
![]()
FSLI 16/2A GNYE
Art:
3281.2
Copied
|
16 mm²
|
Green/yellow
|
|
|
|
EAC
|
72,4 mm
|
12,1 mm
|
49 mm
|
48 mm
|
2
|
A7
|
1
|
2,5 mm²
|
25 mm²
|
2,5 mm²
|
25 mm²
|
2,5 mm²
|
16 mm²
|
14
|
4
|
18 mm
|
|
|
UL 1059
|
|
|
|
|
|
|
|
|
C22.2 No 158
|
TR ZU 004/2011
|
EN 60947-7-2:2009
|
CZ
|
44,7 g
|
50
|
|
Select a variant in the list