CONTA-CLIP

Installation terminals - FRKI

FRKI

The FNT neutral disconnect terminals feature an integral mounting post for attaching the 10x3-mm neutral busbar.

No additional plates or fixings are required,  as a secure contact to the busbar is made using the

no-screw slider for the neutral conductor.

With the FSLI protective earth terminals, the PE potential is connected via the PE foot (which contacts the DIN rail on both sides).

Solid wires and flexible wires with wire-end ferrules can be inserted into the connection mechanism without the need for tools.

The pressure spring opens automatically when the wire is inserted; this ensures a secure contact with the busbar.

A standard screwdriver can be used to open the clamp for release and for the insertion of stranded wire without ferrules.

This range can also be combined with the FDLIS three-level installation terminal range.

The one-level terminals – FRKI, FSLI, and FNT – can be used in combination with the three-level FDLIS installation terminals, as the height of the neutral busbar is identical in both versions.

Where the neutral busbar is not being used with the 16mm terminals, there is the FRK16 in the standard range, this has a central din rail mounting foot and provides a symmetrical layout.

 

Read more
  • Compact
  • Quick & easy installation
  • Polyamide 6.6-V0

Selected variant

Selected variant

Technical data

General data

Rated wire cross section 4 mm²
Colour Beige
Rated voltage IEC 800 V
Rated current IEC 32 A
Mounting TS 35
Rated impulse voltage 8 kV
Overvoltage category III
Contamination degree 3
Approvals CSA, CSA US, KEMA KUR, EAC

Dimensions

Length 52,5 mm
Width 5,1 mm
Height TS 35/7.5 38,5 mm
Height 37,5 mm

Connection data

Connections 2
Number of levels 1
Plug gauge acc. EN 60 947-1 A4
Cross connect channels 2
Cross section single wire from 0,5 mm²
Cross section single wire to 6 mm²
Cross section stranded wire from 0,6 mm²
Cross section stranded wire to 6 mm²
Cross section stranded with ferrule from 0,5 mm²

*Invisible Heading*

Cross section stranded with ferrule to 4 mm²
Rated wire cross section from (AWG) 20
Rated wire cross section to (AWG) 10
Stripping length 12 mm

Materials

Insulation material Polyamide 6.6
Flammability class UL94-V0
Operating temperature from -40 °C
Operating temperature to 120 °C

Approvals

Rated voltage CSA 600 V
Rated current CSA 28 A
CSA test standard C22.2 No 158
Rated voltage CSAus 600 V
Rated current CSAus 28 A
CSAus test standard UL 1059
EAC test standard TR ZU 004/2011
KEMA KEUR test standard EN 60947-7-1:2009

Additional data

Tariff code 85369010
Country of origin BG
Weight 8,25 g
Pack size 100

Product description

The FNT neutral disconnect terminals feature an integral mounting post for attaching the 10x3-mm neutral busbar.

No additional plates or fixings are required,  as a secure contact to the busbar is made using the

no-screw slider for the neutral conductor.

With the FSLI protective earth terminals, the PE potential is connected via the PE foot (which contacts the DIN rail on both sides).

Solid wires and flexible wires with wire-end ferrules can be inserted into the connection mechanism without the need for tools.

The pressure spring opens automatically when the wire is inserted; this ensures a secure contact with the busbar.

A standard screwdriver can be used to open the clamp for release and for the insertion of stranded wire without ferrules.

This range can also be combined with the FDLIS three-level installation terminal range.

The one-level terminals – FRKI, FSLI, and FNT – can be used in combination with the three-level FDLIS installation terminals, as the height of the neutral busbar is identical in both versions.

Where the neutral busbar is not being used with the 16mm terminals, there is the FRK16 in the standard range, this has a central din rail mounting foot and provides a symmetrical layout.

 

Accessories

Related products

Related

crouzet millenium slim on limited time discount
Product news

The smallest logic controller ever on limited time discount

The smallest logic controller by Crouzet is now 20% off for a limited time only! A powerhouse packed into just 17.5mm! Efficiency, adaptability, and seamless integration with free software.

11 questions to get the right signalling device with Auer Signal & OEM Automatic
Blog

11 questions to get the right signalling device – a whitepaper

Do you require signalling devices and beacons in your production process? Download our latest whitepaper!

bespoke solutions electricity meter control boxes
Case studies

Control Box Assembly for Industrial Electricity Metering - A case study

Here, our customer requires control boxes for electricity metering systems. We leveraged our expertise to deliver easy-to-install, ready-to-use assemblies. We look forward to creating more of these bespoke control boxes for our customer.

DC circuit protection PISA M and circuit breakers
Blog

Safeguard systems with DC circuit protection

This blog talks all things DC circuit protection including the key components: electronic circuit breakers, fuses and current monitoring devices. As well as how to choose the right protection.

IATECH, the industrial automation technology exhibition OEM automatic
Company news

Recap of IATECH

Did you get a chance to visit IATECH at The Leicester Marriott Hotel? We had over 33 exhibitors and 8 fantastic Tech Talks throughout the day, Read all about the day, here.

zoller and frohlich cable preparation machines
Product news Blog

Book your Cable Preparation Machinery Demo at OEM

To help experience the capabilities of Z+F machines first-hand, we provide an in-depth demonstration and workshop. These sessions will show the machines in action and allow you to understand their features and gain valuable insight into their operation and benefits.

Parts Rated wire cross section Colour Rated voltage IEC Rated current IEC Rated impulse voltage Approvals Length Width Height TS 35/7.5 Height Connections Plug gauge acc. EN 60 947-1 Cross connect channels Cross section single wire from Cross section single wire to Cross section stranded wire from Cross section stranded wire to Cross section stranded with ferrule from Cross section stranded with ferrule to Rated wire cross section from (AWG) Rated wire cross section to (AWG) Stripping length Rated voltage UL Rated current UL UL test standard Rated voltage CSA Rated current CSA CSA test standard Rated voltage CSAus Rated current CSAus CSAus test standard Rated voltage cUL Rated current cUL cUL test standard EAC test standard KEMA KEUR test standard Country of origin Weight Pack size Price
4 mm²
Beige
800 V
32 A
8 kV
CSA, CSA US, KEMA KUR, EAC
52,5 mm
5,1 mm
38,5 mm
37,5 mm
2
A4
2
0,5 mm²
6 mm²
0,6 mm²
6 mm²
0,5 mm²
4 mm²
20
10
12 mm
600 V
28 A
C22.2 No 158
600 V
28 A
UL 1059
TR ZU 004/2011
EN 60947-7-1:2009
BG
8,25 g
100
4 mm²
Blue
800 V
32 A
8 kV
CSA, CSA US, KEMA KUR, EAC
52,5 mm
5,1 mm
38,5 mm
37,5 mm
2
A4
2
0,5 mm²
6 mm²
0,6 mm²
6 mm²
0,5 mm²
4 mm²
20
10
12 mm
600 V
28 A
C22.2 No 158
600 V
28 A
UL 1059
TR ZU 004/2011
EN 60947-7-1:2009
BG
8,25 g
100
4 mm²
Orange
800 V
32 A
8 kV
CSA, CSA US, KEMA KUR, EAC
52,5 mm
5,1 mm
38,5 mm
37,5 mm
2
A4
2
0,5 mm²
6 mm²
0,6 mm²
6 mm²
0,5 mm²
4 mm²
20
10
12 mm
600 V
28 A
C22.2 No 158
600 V
28 A
UL 1059
TR ZU 004/2011
EN 60947-7-1:2009
BG
8,25 g
100
4 mm²
Green/yellow
CSA, CSA US, KEMA KUR, EAC
52,5 mm
5,1 mm
38,5 mm
37,5 mm
2
A4
1
0,5 mm²
6 mm²
0,6 mm²
6 mm²
0,5 mm²
4 mm²
20
10
12 mm
C22.2 No 158
UL 1059
TR ZU 004/2011
EN 60947-7-2:2009
BG
11,25 g
100
4 mm²
Blue
250 V
32 A
8 kV
KEMA KUR
64 mm
5,1 mm
42,5 mm
41,5 mm
1
A4
1
0,5 mm²
6 mm²
0,6 mm²
6 mm²
0,5 mm²
4 mm²
20
10
12 mm
EN 60947-7-1:2009
BG
9,25 g
100
10 mm²
Beige
800 V
57 A
8 kV
CSA, CSA US, KEMA KUR, EAC
56,5 mm
8,1 mm
40,5 mm
39,8 mm
2
A5
2
1,5 mm²
10 mm²
1,5 mm²
10 mm²
1,5 mm²
10 mm²
22
10
12 mm
600 V
44 A
C22.2 No 158
600 V
44 A
UL 1059
TR ZU 004/2011
EN 60947-7-1:2009
BG
14,25 g
100
10 mm²
Blue
800 V
57 A
8 kV
CSA, CSA US, KEMA KUR, EAC
56,5 mm
8,1 mm
40,5 mm
39,8 mm
2
A5
2
1,5 mm²
10 mm²
1,5 mm²
10 mm²
1,5 mm²
10 mm²
22
10
12 mm
600 V
44 A
C22.2 No 158
600 V
44 A
UL 1059
TR ZU 004/2011
EN 60947-7-1:2009
BG
14,25 g
100
10 mm²
Orange
800 V
57 A
8 kV
CSA, CSA US, KEMA KUR, EAC
56,5 mm
8,1 mm
40,5 mm
39,8 mm
2
A5
2
1,5 mm²
10 mm²
1,5 mm²
10 mm²
1,5 mm²
10 mm²
22
10
12 mm
600 V
44 A
C22.2 No 158
600 V
44 A
UL 1059
TR ZU 004/2011
EN 60947-7-1:2009
BG
14,25 g
100
10 mm²
Red
800 V
57 A
8 kV
CSA, CSA US, KEMA KUR, EAC
56,5 mm
8,1 mm
40,5 mm
39,8 mm
2
A5
2
1,5 mm²
10 mm²
1,5 mm²
10 mm²
1,5 mm²
10 mm²
22
10
12 mm
600 V
44 A
C22.2 No 158
600 V
44 A
UL 1059
TR ZU 004/2011
EN 60947-7-1:2009
CZ
14,25 g
100
10 mm²
Green/yellow
CSA, CSA US, KEMA KUR, EAC
56,5 mm
8,1 mm
40,5 mm
39,8 mm
2
A5
1
1,5 mm²
10 mm²
1,5 mm²
10 mm²
1,5 mm²
10 mm²
22
10
12 mm
C22.2 No 158
UL 1059
TR ZU 004/2011
EN 60947-7-2:2009
BG
20,25 g
100
10 mm²
Blue
250 V
57 A
8 kV
KEMA KUR
67,5 mm
8,1 mm
40,5 mm
39,8 mm
1
A5
1
1,5 mm²
10 mm²
1,5 mm²
10 mm²
1,5 mm²
10 mm²
22
10
12 mm
EN 60947-7-1:2009
BG
16,25 g
100
10 mm²
Beige
800 V
57 A
8 kV
EAC
82,4 mm
8,1 mm
39,8 mm
3
A3
2
1,5 mm²
10 mm²
1,5 mm²
10 mm²
1,5 mm²
10 mm²
16
8
12 mm
600 V
44 A
UL 1059
44 V
600 A
C22.2 No 158
TR ZU 004/2011
EN 60947-7-1:2009
BG
27,09 g
50
10 mm²
Blue
800 V
57 A
8 kV
EAC
82,4 mm
8,1 mm
39,8 mm
3
A3
2
1,5 mm²
10 mm²
1,5 mm²
10 mm²
1,5 mm²
10 mm²
16
8
12 mm
600 V
44 A
UL 1059
44 V
600 A
C22.2 No 158
TR ZU 004/2011
EN 60947-7-1:2009
BG
27,09 g
50
10 mm²
Orange
800 V
57 A
8 kV
EAC
82,4 mm
8,1 mm
39,8 mm
3
A3
2
1,5 mm²
10 mm²
1,5 mm²
10 mm²
1,5 mm²
10 mm²
16
8
12 mm
600 V
44 A
UL 1059
44 V
600 A
C22.2 No 158
TR ZU 004/2011
EN 60947-7-1:2009
BG
27,09 g
50
10 mm²
Green/yellow
EAC
82,4 mm
8,1 mm
39,8 mm
3
A3
2
1,5 mm²
10 mm²
1,5 mm²
10 mm²
1,5 mm²
10 mm²
16
8
12 mm
UL 1059
C22.2 No 158
TR ZU 004/2011
EN 60947-7-2:2009
BG
33,87 g
50
16 mm²
Beige
1000 V
76 A
8 kV
EAC
72,4 mm
12,1 mm
49 mm
48 mm
2
A7
2
2,5 mm²
25 mm²
2,5 mm²
25 mm²
2,5 mm²
16 mm²
14
4
18 mm
600 V
75 A
UL 1059
75 V
600 A
C22.2 No 158
TR ZU 004/2011
EN 60947-7-1:2009
CZ
17,8 g
50
16 mm²
Blue
1000 V
76 A
8 kV
EAC
72,4 mm
12,1 mm
49 mm
48 mm
2
A7
2
2,5 mm²
25 mm²
2,5 mm²
25 mm²
2,5 mm²
16 mm²
14
4
18 mm
600 V
75 A
UL 1059
75 V
600 A
C22.2 No 158
TR ZU 004/2011
EN 60947-7-1:2009
CZ
17,8 g
50
16 mm²
Orange
1000 V
76 A
8 kV
EAC
72,4 mm
12,1 mm
49 mm
48 mm
2
A7
2
2,5 mm²
25 mm²
2,5 mm²
25 mm²
2,5 mm²
16 mm²
14
4
18 mm
600 V
75 A
UL 1059
75 V
600 A
C22.2 No 158
TR ZU 004/2011
EN 60947-7-1:2009
CZ
17,8 g
50
16 mm²
Green/yellow
EAC
72,4 mm
12,1 mm
49 mm
48 mm
2
A7
1
2,5 mm²
25 mm²
2,5 mm²
25 mm²
2,5 mm²
16 mm²
14
4
18 mm
UL 1059
C22.2 No 158
TR ZU 004/2011
EN 60947-7-2:2009
CZ
44,7 g
50

Selected variant

Select a variant in the list

Contact us
If you need any help, you can contact us in one of the following ways:
0116 284 9900
Send e-mail
Use live chat
Do you need help?
Logo

Cookie settings for OEM.CO.UK

Cookies help us improve your experience with us, so in order to be able to handle login information, offer you personalised content and for basic functionality of this website, we use some cookies.

We will never sell on any information about you. 

You can accept all cookies or personalise your cookies preferences, you can also change your cookie preferences at any time by visiting our contact page.

Necessary Cookies

These cookies are necessary for the website to work and can not be turned off in our systems. They are usually used only in response to actions you have taken in connection with a service request, for example when setting personal preferences, logging in or filling out a form.

Analysis and measurement cookies

These cookies allow us to count the number of visits and traffic sources so that we can measure and improve our website performance. They help us know which pages are more or less popular and how visitors navigate around the site. The information that these cookies collect is aggregated and therefore completely anonymous. If you do not allow these cookies, we do not know when you have visited our website.

Marketing cookies

These cookies can be added by our partners. They can use them to create a profile of you, based on your interests, to show you more relevant information. They do not store any personal information - only information about your browser and device. If you do not accept these cookies, you will have a more general and less customized user experience.