PULS
Puls Dimension Q is a new generation of power supply unit with very small construction dimensions and many technical benefits. The unit has low inrush current (even with warm starts), active PFC, which provides a power factor close to one, expanded temperature range and active protection against line transients. Furthermore, there is a relay output (DC OK) that is deactivated when the output voltage deviates more than 10% from the set value. The bonus power provides an extra 50% boost with retained 24 V, which is an advantage when connected loads have high starting currents. The unit also has a high short-circuit current that simplifies tripping of secondary fuses. Both the bonus power and short-circuit current are time-limited to 4 seconds to avoid constant overloading of the unit and wiring. High efficiency provides long lifetime and low temperatures. The power supply unit can be connected for 2-phase operation with Inom up to 40°C. For higher temperatures, the load current must be reduced.
We recommend free space of 60 mm above/under the unit and 15 mm at the sides.
Bonus power
The power supply unit has bonus power that enables high power extraction with retained 24 V dc for 4 seconds, which is a major advantage when connected loads have high starting currents, such as the case with motors. How often bonus power can be utilised depends on the application. With the following diagram and formula, the repeat time can be calculated for each application. The bonus power is available as soon as the power supply unit is started and directly after a short circuit.
Bonus power | Operating characteristics |
|
|
Po | Nominal load current |
Ppeak | Peak current |
To | Time between bonus power |
Tpeak | Peak current I time |
Operating cycle | Tpeak / (Tpeak + To) |
To | Tpeak - (operating cycle * Tpeak) / operating cycle |
Example: Nominal load current (Po) is 15 A. Peak current (Ppeak) is 24 A = 120%. The peak time is 3 seconds. 15 A = 75% of Inom. According to the diagram, the operating cycle is 50%. To = 3 - (0.5 * 3) / 0.5 = 3 Maximum repeat time of bonus power is 3 seconds. |
Input data |
|
---|---|
Input voltage ac | 380-480 V |
Input voltage ac min | 323 V AC |
Input voltage ac max | 552 V AC |
Inrush current at 400 V ac typical | 3 A |
Input voltage range | Wide-range |
Power factor at 400 V ac, full load. Typical | 0,94 |
Number of phases | 3 |
Output data |
|
Output voltage | 24 V DC |
Output voltage min | 24 V DC |
Output voltage max | 28 V DC |
Output current | 20 A |
Power | 480 W |
Efficiency / Lifetime / MTBF |
|
Efficiency at 400 V ac, typical | 94,2 % |
Efficiency at 400 V ac, full load, typical | 95 % |
Lifetime at 400 V ac, full load and +40 ° C | 105000 h |
MTBF (IEC 61709) 400 V ac, max loan, +40 °C | 690000 h |
Dimensions |
|
Width | 65 mm |
Height | 124 mm |
*Invisible Heading* |
|
---|---|
Depth | 127 mm |
Weight | 0,87 kg |
Other |
|
Approvals | CB, CE, CSA, CSA US, cRUus, cULus, GL |
Hold time at 400 V ac, typical full load | 22 ms |
IP class | IP20 |
Clamp type | Spring-clamp |
Material protection | Aluminium |
Supply frequency | 50-60 ±6 % |
Ripple max | 100 mV pp |
Series | Dimension Q |
Power consumption at 400 V ac | 0,79 A |
Power drop from +60 °C to + 70 °C | 12 W/°C |
Temperature min without derating | -25 °C |
Temperature max without derating | 60 °C |
Type Power Supply | AC-DC |
DC relay output | Yes |
Active Transient | Yes |
Puls Dimension Q is a new generation of power supply unit with very small construction dimensions and many technical benefits. The unit has low inrush current (even with warm starts), active PFC, which provides a power factor close to one, expanded temperature range and active protection against line transients. Furthermore, there is a relay output (DC OK) that is deactivated when the output voltage deviates more than 10% from the set value. The bonus power provides an extra 50% boost with retained 24 V, which is an advantage when connected loads have high starting currents. The unit also has a high short-circuit current that simplifies tripping of secondary fuses. Both the bonus power and short-circuit current are time-limited to 4 seconds to avoid constant overloading of the unit and wiring. High efficiency provides long lifetime and low temperatures. The power supply unit can be connected for 2-phase operation with Inom up to 40°C. For higher temperatures, the load current must be reduced.
We recommend free space of 60 mm above/under the unit and 15 mm at the sides.
Bonus power
The power supply unit has bonus power that enables high power extraction with retained 24 V dc for 4 seconds, which is a major advantage when connected loads have high starting currents, such as the case with motors. How often bonus power can be utilised depends on the application. With the following diagram and formula, the repeat time can be calculated for each application. The bonus power is available as soon as the power supply unit is started and directly after a short circuit.
Bonus power | Operating characteristics |
|
|
Po | Nominal load current |
Ppeak | Peak current |
To | Time between bonus power |
Tpeak | Peak current I time |
Operating cycle | Tpeak / (Tpeak + To) |
To | Tpeak - (operating cycle * Tpeak) / operating cycle |
Example: Nominal load current (Po) is 15 A. Peak current (Ppeak) is 24 A = 120%. The peak time is 3 seconds. 15 A = 75% of Inom. According to the diagram, the operating cycle is 50%. To = 3 - (0.5 * 3) / 0.5 = 3 Maximum repeat time of bonus power is 3 seconds. |
Renowned for high-quality cable cutting and crimping tools, Klauke serves electrical contractors, cable jointers, and linemen across a spectrum of sectors
At OEM Automatic, we can supply a series of components for your one project. All under one roof. This case study discusses how we supplied several components for our customer's new electro-pneumatic control box.
To promote constant and reliable performance, as well as a longer life of parts in the vehicle, it is important to consider the right cable protector.
We have now added switch disconnectors to our range! Switch disconnectors contribute to the overall functionality and safety of electrical systems.
LOCC-Box from Lutze is an intelligent current monitoring device that provides reliable protection of DC circuits in a slimline 8.1mm housing.
OEM Automatic has integrated push-in technology into it's product offering for many years now. In this blog post, we'll explore the various benefits of push-in technology and some of the products we offer that make use of this innovation, such as push-in terminals, push-in sockets, and even push-in heaters.
|
|
|
|
|
||
---|---|---|---|---|---|---|
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
Parts | Approvals | Conformal coated | Price | ||
---|---|---|---|---|---|
PSU 3PH 380-480V ac I/P 24V dc 20A 480W O/P
Art:
QT20.241
Copied
|
CB, CE, CSA, CSA US, cRUus, cULus, GL
|
|
| ||
PSU 3PH 380-480V ac I/P 24V dc 20A 480W O/P Conf. Coated
Art:
QT20.241-C1
Copied
|
CB, CE, CSA US, cRUus, cULus, EN 50155, GL
|
Yes
|
|
Select a variant in the list