Control relay for phase monitoring with regeneration of voltage and asymmetry. Adjustable switch at the front for adjustment of correct voltage in 3-phase networks. Voltage switch's position is not registered until the operating voltage is switched on. If the switch position is changed during operation, all LEDs (LED indications) begin to flash but the unit will continue to function normally with the voltage that was set at the most recent power connection. The LEDs return to normal function when the correct voltage is restored. The relay monitors the correct phase sequence between the three phases or if any phase is lacking (measured U<0.7xUn), 70 % of the returned voltage. The asymmetry setting is made at the front between 5 and 15 % (the rated voltage between the phases Un x degree of asymmetry, %). Deviations in over-/under-voltage are adjustable between -2 and -20 % of the line voltage (window relay function). In the event of incorrect phase sequence or phase interruption, the relay immediately produces an alarm (drops out), and in the event of an asymmetry or voltage fault, the relay drops out after the set time Tt. If the power is switched on with a measured fault, the relay remains deactivated. Fault indication is accomplished with LEDs, which also differentiates between the various fault causes. If a fault remains after the time delay, a non-flashing LED indicates an asymmetry fault and a flashing LED indicates over-/under-voltage. The LED indication that shows this is labelled with Def. on the front of the relay. Green LED (Un) indicates supply voltage OK. Yellow LED (R) indicates active relay output.
Approvals | CSA, GL, RoHS, UL |
---|---|
Breaking capacity | 5A, 250V AC/DC |
Function | Phase Sequence, Phase Failure, Asymmetry, Under/Overvoltage |
IP class connection | IP20 |
IP class housing | IP30 |
Mounting | 35 mm DIN-Rail |
Output | Relay |
Selection of rated voltage | 220, 380, 400, 415, 440, 480 V |
Storage temperature max | 70 °C |
Storage temperature min | -40 °C |
---|---|
Supply voltage | 3 x 220-480V AC |
Temperature operational max | 50 °C |
Temperature operational min | -20 °C |
Time delay alarm | 0,2 s |
Time delay startup | 0,5 s |
Time delay when exceeding the limit value | 0,1-10s |
Weight | 130 g |
Phase interruption, phase sequence and asymmetry
1: L1
2: L2
3: L3
4: Limit value for asymmetry
5: Hysteresis
6: Relay
7: Delay upon exceeding limit value Tt
Over and under voltage
1: Limit value, over-voltage
2: Hysteresis
3: Limit value, under-voltage
4: L1, L2, L3
5: Relay
6: Delay upon exceeding limit value Tt
Control relay for phase monitoring with regeneration of voltage and asymmetry. Adjustable switch at the front for adjustment of correct voltage in 3-phase networks. Voltage switch's position is not registered until the operating voltage is switched on. If the switch position is changed during operation, all LEDs (LED indications) begin to flash but the unit will continue to function normally with the voltage that was set at the most recent power connection. The LEDs return to normal function when the correct voltage is restored. The relay monitors the correct phase sequence between the three phases or if any phase is lacking (measured U<0.7xUn), 70 % of the returned voltage. The asymmetry setting is made at the front between 5 and 15 % (the rated voltage between the phases Un x degree of asymmetry, %). Deviations in over-/under-voltage are adjustable between -2 and -20 % of the line voltage (window relay function). In the event of incorrect phase sequence or phase interruption, the relay immediately produces an alarm (drops out), and in the event of an asymmetry or voltage fault, the relay drops out after the set time Tt. If the power is switched on with a measured fault, the relay remains deactivated. Fault indication is accomplished with LEDs, which also differentiates between the various fault causes. If a fault remains after the time delay, a non-flashing LED indicates an asymmetry fault and a flashing LED indicates over-/under-voltage. The LED indication that shows this is labelled with Def. on the front of the relay. Green LED (Un) indicates supply voltage OK. Yellow LED (R) indicates active relay output.
Renowned for high-quality cable cutting and crimping tools, Klauke serves electrical contractors, cable jointers, and linemen across a spectrum of sectors
At OEM Automatic, we can supply a series of components for your one project. All under one roof. This case study discusses how we supplied several components for our customer's new electro-pneumatic control box.
To promote constant and reliable performance, as well as a longer life of parts in the vehicle, it is important to consider the right cable protector.
We have now added switch disconnectors to our range! Switch disconnectors contribute to the overall functionality and safety of electrical systems.
LOCC-Box from Lutze is an intelligent current monitoring device that provides reliable protection of DC circuits in a slimline 8.1mm housing.
OEM Automatic has integrated push-in technology into it's product offering for many years now. In this blog post, we'll explore the various benefits of push-in technology and some of the products we offer that make use of this innovation, such as push-in terminals, push-in sockets, and even push-in heaters.
|
|
|
|
|
||
---|---|---|---|---|---|---|
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|