Crydom's signature family of solid state relays. Ratings from 10A to 40A @ 24-140 VAC, 12A to 90A @ 80-530 VAC and 10A to 125A @ 24-280 VAC - SCR output for heavy industrial loads - AC or DC control - zero voltage (resistive loads) or random-fire (inductive loads) output - LED input status indicator optional.
- Ratings from 10A to 40A @ 24-140 VAC
- SCR output for heavy industrial loads
- Zero voltage or instantaneous turn-on outputs
- UL/CSA/VDE Approved, CE Compliant to EN60950-1
- Improved SEMS screw and washer
- Redesigned housing with anti-rotation barriers
- AC or DC control
- Direct bond copper substrate
- EMC compliant to Level 3
- Direct power lead frame
- Epoxy free design
Technical Data
Output specification (5)
Description | 10A | 25A | 40A |
Operating Voltage (47-440Hz) [Vrms] (6) | 24-140 | 24-140 | 24-140 |
Transient Overvoltage [Vpk] | 600 | 600 | 600 |
Maximum Off-State Leakage Current @ Rated Voltage [mArms] (7) | 1 | 1 | 1 |
Minimum Off-State dv/dt @ Maximum Rated Voltage [V/μsec] | 500 | 500 | 500 |
Maximum Load Current [Arms] (2) (8) | 10 | 25 | 40 |
Minimum Load Current [mArms] | 150 | 150 | 150 |
Maximum 1 Cycle Surge Current (50/60Hz) [Apk] | 115/120 | 239/250 | 597/625 |
Maximum On-State Voltage Drop @ Rated Current [Vrms] | 1.15 | 1.15 | 1.15 |
Thermal Resistance Junction to Case (Rjc) [°C/W] 1.03 0.8 0.5 | 1.03 | 0.8 | 0.5 |
Maximum 1/2 Cycle I² t for Fusing (50/60Hz) [A² sec] | 66/60 | 285/259 | 1770/1629 |
Minimum Power Factor (at Maximum Load) (3) | 0.5 | 0.5 | 0.5 |
Input Specifications (5)
Description | D12xx | A12xx | A12xxE |
Control Voltage Range | 3-32 VDC | 90-280 Vrms | 18-36 Vrms |
Maximum Reverse Voltage | -32 VDC | - | - |
Minimum Turn-On Voltage | 3.0 VDC (9) | 90 Vrms | 18 Vrms |
Must Turn-Off Voltage | 1.0 VDC | 10 Vrms | 4 Vrms |
Minimum Input Current [mA] | 7 | 5 | 16 |
Maximum Input Current [mA] | 12 | 10 | 20 |
Nominal Input Impedance [Ohms] | Current regulated |
Maximum Turn-On Time [msec] | ½ Cycle (10) | 20 | 20 |
Maximum Turn-Off Time [msec] | ½ Cycle | 30 | 30 |
General Specifications (5)
Description | Parameters |
Dielectric Strength, Input/Output/Base (50/60Hz) | 4000 Vrms |
Minimum Insulation Resistance (@ 500 VDC) | 109 Ohm |
Maximum Capacitance, Input/Output | 8 pF |
Ambient Operating Temperature Range | -40 to 80°C |
Ambient Storage Temperature Range | -40 to 125°C |
Weight (typical) | 2.6 oz (74.9g) |
Housing Material | UL 94 V-0 |
Baseplate Material | Aluminium |
Input Terminal Screw Torque Range (in-lb/Nm) | 13-15 / 1.5-1.7 |
Load Terminal Screw Torque Range (in-lb/Nm) | 18-20 / 2.0-2.2 |
SSR Mounting Screw Torque Range (in-lb/Nm) | 18-20 / 2.0-2.2 |
Input/Load Terminal Screw Torque Range (in-lb/Nm) (2) | w/”K” option 8-10 / 0.9-1.13 |
Input/Output Terminal Screw Thread Size | #6-32 UNC / #8-32 UNC |
Humidity per IEC60068-2-78 | 93% non-condensing |
LED Input Status Indicator | w/”G” option (green) |
MTBF (Mean Time Between Failures) at 40°C ambient temperature (11) | 11,641,553 hours (1,328 years) |
MTBF (Mean Time Between Failures) at 60°C ambient temperature (11) | 7,210,376 hours (823 years) |
Wiring Diagram
Equivalent Circuit Block Diagrams
Mechanical Specifications (5)
Tolerances: ±0.02 in / 0.5 mm
All dimensions are in: inches (millimeters)
Surge Current Information | Thermal Derate Information |

| 
|
General notes
1) Single pair (up to 25A) Double pair* (up to 50A). *Caution: User must connect both pairs.
2) Option “K” is designed and tested for use with printed circuit boards or ring/fork terminals having a thickness between 0.031 and 0.093 inches (0.79 to 2.36 mm), and loads rated up to 50 Amps. For higher load currents, the “K” standoff temperature must not exceed 105°C.
3) Output will self-trigger between 450-600Vpk, Min. power factor 0.7 or higher, not suitable for capacitive loads.
4) Instantaneous turn-on version is not recommended for capacitive loads. Use zero turn-on only.
5) All parameters at 25°C unless otherwise specified.
6) For “S” option, operating voltage frequency is 47-63Hz.
7) For parts with option “S” maximum leakage current is 10mA.
8) Heat sinking required, see derating curves.
9) Increase minimum voltage by 1V for operations from -20 to -40°C.
10) Turn-on time for instantaneous turn-on versions is 0.02 msec (DC control Models).
11) All parameters at 50% power rating and 100% duty cycle.
12) Load can be wired to either SSR output terminal 1 or 2.
13) Elective Input Status LED, “G” option
14) Elective Overvoltage Protection, “P” option.
15) Elective Internal Snubber, “S” option.
16) Mechanical dimensions vary from G3 models.
Agency Approvals
EN60950 : Meets the requirements of sections1.5: 1,7: 2.9: 2.10.5.3: 4.2: 4.5: 4.7:
Designed in accordance with the requirements of IEC 62314
IEC 61000-4-2 : Electrostatic Discharge – Level 3
IEC 61000-4-4 : Electrically Fast Transients – Level 3
IEC 61000-4-5 : Electrical Surges – Level 3
IEC 60068-2-6 : Vibration 0.33mm and 0.75 mm Amplitude over 10-55 Hz
IEC 60068-2-27 : Shock Resistance 15g/11ms
cRU US E116949 SA LR81689 VDE 10143 UG CE RoSH
Part Numbers
Product selection
Control Voltage | 10A | 25A | 40A |
3-32 VDC | D1210 | D1225 | D1240 |
90-280 VAC | A1210 | A1225 | A1240 |
18-36 VAC | A1210E | A1225E | A1240E |
Available Options