STEGO

Filter fans - Old Range

FF 018

STEGO's filter fans have a special fan housing design so as to run as quietly as possible without sacrificing high airflow. Moreover, the location of the plates makes it especially difficult for water and dust to enter the cabinet.

Filters and fans can be changed from the outside of the cabinet; consequently, the unit does not need to be turned off during fan maintenance.

For optimal performance, the filter fan should be mounted at the lower edge of the cabinet. At the upper edge of the corresponding side, a exit cover with a filter should be mounted for evacuation of surplus air. The exit cover is the same as the fan housing and the cut-outs are also the same.

 

All filter fans are UL-approved and able to withstand the elements, including UV radiation.


 

Read more
  • Quick installation
  • Minimal installation depth
  • Low noise level
  • IP55 with F5/M5 filter mat

Selected variant

Selected variant

Technical data

General Data

Air capacity 21 m³/h
Air volume free blowing 21 m³/h
Air volume free blowing with G3 filter 16 m³/h
Number of fans 1
Sound level 31 dB

Dimensions

Width 129 mm
Height 134 mm
Depth 80 mm
Behind panel depth 45 mm
Hole size 97x97 mm
Weight 0,6 kg

Materials

Colour Grey RAL 7035
Material plastic housing Plastic
Flammability class UL94-V0
Materials fan Aluminium

*Invisible Heading*

Material of rotor Plastic
Filter grade 94 %

Rated Operating Conditions

Voltage max 230 V ac
Voltage min 230 V ac
Frequency 50 Hz
Power consumption 13 W
Power consumption 80 mA
Life span 50000 h
Storage temperature -40°C ... +70°C
Operational temperature -10°C ... +70°C
Operating humidity < 90% RH
Humidity storage <90% RH

Safety and Approvals

IP class IP54, IP55
Approvals CE, cULus, EAC, RoHS, UL, UL E234324, UV - UL746C (f1), VDE

Product description

STEGO's filter fans have a special fan housing design so as to run as quietly as possible without sacrificing high airflow. Moreover, the location of the plates makes it especially difficult for water and dust to enter the cabinet.

Filters and fans can be changed from the outside of the cabinet; consequently, the unit does not need to be turned off during fan maintenance.

For optimal performance, the filter fan should be mounted at the lower edge of the cabinet. At the upper edge of the corresponding side, a exit cover with a filter should be mounted for evacuation of surplus air. The exit cover is the same as the fan housing and the cut-outs are also the same.

 

All filter fans are UL-approved and able to withstand the elements, including UV radiation.


 

Accessories

Related

bespoke solutions electricity meter control boxes
Case studies

Control Box Assembly for Industrial Electricity Metering - A case study

Here, our customer requires control boxes for electricity metering systems. We leveraged our expertise to deliver easy-to-install, ready-to-use assemblies. We look forward to creating more of these bespoke control boxes for our customer.

DC circuit protection PISA M and circuit breakers
Blog

Safeguard systems with DC circuit protection

This blog talks all things DC circuit protection including the key components: electronic circuit breakers, fuses and current monitoring devices. As well as how to choose the right protection.

IATECH, the industrial automation technology exhibition OEM automatic
Company news

Recap of IATECH

Did you get a chance to visit IATECH at The Leicester Marriott Hotel? We had over 33 exhibitors and 8 fantastic Tech Talks throughout the day, Read all about the day, here.

zoller and frohlich cable preparation machines
Product news Blog

Book your Cable Preparation Machinery Demo at OEM

To help experience the capabilities of Z+F machines first-hand, we provide an in-depth demonstration and workshop. These sessions will show the machines in action and allow you to understand their features and gain valuable insight into their operation and benefits.

IATECH industrial automation components exhibition in at leicester marriott hotel by OEM Automatic
Company news

OEM introduces IATECH - The Industrial Automation Technology Expo

We are thrilled to announce the launch of IATECH, THe Industrial Automation Technology expo at Leicester Marriott Hotel on 23rd October. The ultimate platform for showcasing our extensive product range and broad business areas, featuring over 50 leading suppliers under one roof!

automation components for specialist vehicles
Blog

Automation Components for Specialist Vehicles

The specialist vehicle industry can include automotive and EV, heavy vehicles such as agriculture and rail, and marine.  This email takes you through some of the various products we offer for specialist vehicle applications.

Parts Air capacity Air volume free blowing Air volume free blowing with G3 filter Number of fans Sound level Width Height Depth Behind panel depth Hole size Weight Materials fan Material of rotor Voltage max Voltage min Frequency Power consumption Power consumption Life span Storage temperature Operational temperature IP class Approvals Price
21 m³/h
21 m³/h
16 m³/h
1
31 dB
129 mm
134 mm
80 mm
45 mm
97x97 mm
0,6 kg
Aluminium
Plastic
230 V ac
230 V ac
50 Hz
13 W
80 mA
50000 h
-40°C ... +70°C
-10°C ... +70°C
IP54, IP55
CE, cULus, EAC, RoHS, UL, UL E234324, UV - UL746C (f1), VDE
24 m³/h
24 m³/h
18 m³/h
1
31 dB
129 mm
134 mm
80 mm
45 mm
97x97 mm
0,6 kg
Aluminium
Plastic
120 V ac
120 V ac
60 Hz
13 W
160 mA
50000 h
-40°C ... +70°C
-10°C ... +70°C
IP54, IP55
CE, cULus, EAC, RoHS, UL, UL E234324, UV - UL746C (f1)
24 m³/h
24 m³/h
18 m³/h
129 mm
134 mm
80 mm
45 mm
97x97 mm
0,3 kg
-40°C ... +70°C
-10°C ... +70°C
IP54
CE, cULus, EAC, RoHS, UL, UL E234324, UV - UL746C (f1), VDE
55 m³/h
55 m³/h
42 m³/h
1
40 dB
157 mm
170 mm
98 mm
58 mm
125x125 mm
1 kg
Aluminium
Plastic
230 V ac
230 V ac
50 Hz
15 W
100 mA
50000 h
-40°C ... +70°C
-10°C ... +70°C
IP54, IP55
CE, cULus, EAC, RoHS, UL, UL E234324, UV - UL746C (f1), VDE
63 m³/h
63 m³/h
48 m³/h
1
40 dB
157 mm
170 mm
98 mm
58 mm
125x125 mm
1 kg
Aluminium
Plastic
120 V ac
120 V ac
60 Hz
15 W
180 mA
50000 h
-40°C ... +70°C
-10°C ... +70°C
IP54, IP55
CE, cULus, EAC, RoHS, UL, UL E234324, UV - UL746C (f1), VDE
63 m³/h
63 m³/h
48 m³/h
157 mm
170 mm
98 mm
58 mm
125x125 mm
0,4 kg
-40°C ... +70°C
-10°C ... +70°C
IP54, IP55
CE, cULus, EAC, RoHS, UL, UL E234324, UV - UL746C (f1), VDE
102 m³/h
102 m³/h
68 m³/h
1
39 dB
209 mm
226 mm
136 mm
86 mm
176x176 mm
1,3 kg
Aluminium
Plastic
230 V ac
230 V ac
50 Hz
15 W
100 mA
50000 h
-40°C ... +70°C
-10°C ... +70°C
IP54, IP55
CE, cULus, EAC, RoHS, UL, UL E234324, UV - UL746C (f1), VDE
117 m³/h
117 m³/h
78 m³/h
1
39 dB
209 mm
226 mm
136 mm
86 mm
176x176 mm
1,3 kg
Aluminium
Plastic
120 V ac
120 V ac
60 Hz
15 W
180 mA
50000 h
-40°C ... +70°C
-10°C ... +70°C
IP54, IP55
CE, cULus, EAC, RoHS, UL, UL E234324, UV - UL746C (f1)
200 m³/h
200 m³/h
125 m³/h
1
52 dB
209 mm
226 mm
145 mm
95 mm
176x176 mm
1,7 kg
Aluminium
Steel
230 V ac
230 V ac
50 Hz
45 W
320 mA
50000 h
-25°C ... +50°C
-25°C ... +50°C
IP54, IP55
CE, cULus, EAC, RoHS, UL, UL E234324, UV - UL746C (f1), VDE
230 m³/h
230 m³/h
143 m³/h
1
39 dB
209 mm
226 mm
136 mm
86 mm
176x176 mm
1,7 kg
Aluminium
Steel
120 V ac
120 V ac
60 Hz
39 W
470 mA
50000 h
-25°C ... +60°C
-25°C ... +60°C
IP54, IP55
CE, cULus, EAC, RoHS, UL, UL E234324, UV - UL746C (f1)
117 m³/h
117 m³/h
78 m³/h
209 mm
226 mm
136 mm
86 mm
176x176 mm
0,6 kg
-40°C ... +70°C
-10°C ... +70°C
IP54, IP55
CE, cULus, EAC, RoHS, UL, UL E234324, UV - UL746C (f1), VDE
300 m³/h
300 m³/h
230 m³/h
4
56 dB
284 mm
284 mm
110 mm
65 mm
250x250 mm
3,3 kg
Aluminium
Plastic
230 V ac
230 V ac
50 Hz
68 W
400 mA
50000 h
-40°C ... +70°C
-10°C ... +70°C
IP54
CE, cULus, EAC, RoHS, UL, UL E234324, UV - UL746C (f1), VDE
345 m³/h
345 m³/h
264 m³/h
4
56 dB
284 mm
284 mm
110 mm
65 mm
250x250 mm
3,3 kg
Aluminium
Plastic
120 V ac
120 V ac
60 Hz
68 W
800 mA
50000 h
-40°C ... +70°C
-10°C ... +70°C
IP54
CE, cULus, EAC, RoHS, UL, UL E234324, UV - UL746C (f1)
550 m³/h
550 m³/h
300 m³/h
1
65 dB
284 mm
284 mm
152 mm
107 mm
250x250 mm
2,7 kg
Aluminium
Steel
230 V ac
230 V ac
50 Hz
64 W
300 mA
50000 h
-25°C ... +70°C
-25°C ... +70°C
IP54
CE, cULus, EAC, RoHS, UL, UL E234324, UV - UL746C (f1), VDE
632 m³/h
632 m³/h
345 m³/h
1
65 dB
284 mm
284 mm
152 mm
107 mm
250x250 mm
2,7 kg
Aluminium
Steel
120 V ac
120 V ac
60
85 W
780 mA
50000 h
-25°C ... +70°C
-25°C ... +70°C
IP54
CE, cULus, EAC, RoHS, UL, UL E234324, UV - UL746C (f1)
345 m³/h
345 m³/h
264 m³/h
284 mm
284 mm
67 mm
22 mm
250x250 mm
1 kg
-40°C ... +70°C
-10°C ... +70°C
IP54, IP55
CE, cULus, EAC, RoHS, UL, UL E234324, UV - UL746C (f1)

Selected variant

Select a variant in the list

Contact us
If you need any help, you can contact us in one of the following ways:
0116 284 9900
Send e-mail
Use live chat
Do you need help?
Logo

Cookie settings for OEM.CO.UK

Cookies help us improve your experience with us, so in order to be able to handle login information, offer you personalised content and for basic functionality of this website, we use some cookies.

We will never sell on any information about you. 

You can accept all cookies or personalise your cookies preferences, you can also change your cookie preferences at any time by visiting our contact page.

Necessary Cookies

These cookies are necessary for the website to work and can not be turned off in our systems. They are usually used only in response to actions you have taken in connection with a service request, for example when setting personal preferences, logging in or filling out a form.

Analysis and measurement cookies

These cookies allow us to count the number of visits and traffic sources so that we can measure and improve our website performance. They help us know which pages are more or less popular and how visitors navigate around the site. The information that these cookies collect is aggregated and therefore completely anonymous. If you do not allow these cookies, we do not know when you have visited our website.

Marketing cookies

These cookies can be added by our partners. They can use them to create a profile of you, based on your interests, to show you more relevant information. They do not store any personal information - only information about your browser and device. If you do not accept these cookies, you will have a more general and less customized user experience.