STEGO
STEGO's filter fans have a special fan housing design so as to run as quietly as possible without sacrificing high airflow. Moreover, the location of the plates makes it especially difficult for water and dust to enter the cabinet.
Filters and fans can be changed from the outside of the cabinet; consequently, the unit does not need to be turned off during fan maintenance.
For optimal performance, the filter fan should be mounted at the lower edge of the cabinet. At the upper edge of the corresponding side, a exit cover with a filter should be mounted for evacuation of surplus air. The exit cover is the same as the fan housing and the cut-outs are also the same.
Â
All filter fans are UL-approved and able to withstand the elements, including UV radiation.
Â
General Data |
|
---|---|
Air capacity | 21 m³/h |
Air volume free blowing | 21 m³/h |
Air volume free blowing with G3 filter | 16 m³/h |
Number of fans | 1 |
Sound level | 31 dB |
Dimensions |
|
Width | 129 mm |
Height | 134 mm |
Depth | 80 mm |
Behind panel depth | 45 mm |
Hole size | 97x97 mm |
Weight | 0,6 kg |
Materials |
|
Colour | Grey RAL 7035 |
Material plastic housing | Plastic |
Flammability class | UL94-V0 |
Materials fan | Aluminium |
*Invisible Heading* |
|
---|---|
Material of rotor | Plastic |
Filter grade | 94 % |
Rated Operating Conditions |
|
Voltage max | 230 V ac |
Voltage min | 230 V ac |
Frequency | 50 Hz |
Power consumption | 13 W |
Power consumption | 80 mA |
Life span | 50000 h |
Storage temperature | -40°C ... +70°C |
Operational temperature | -10°C ... +70°C |
Operating humidity | < 90% RH |
Humidity storage | <90% RH |
Safety and Approvals |
|
IP class | IP54, IP55 |
Approvals | CE, cULus, EAC, RoHS, UL, UL E234324, UV - UL746C (f1), VDE |
STEGO's filter fans have a special fan housing design so as to run as quietly as possible without sacrificing high airflow. Moreover, the location of the plates makes it especially difficult for water and dust to enter the cabinet.
Filters and fans can be changed from the outside of the cabinet; consequently, the unit does not need to be turned off during fan maintenance.
For optimal performance, the filter fan should be mounted at the lower edge of the cabinet. At the upper edge of the corresponding side, a exit cover with a filter should be mounted for evacuation of surplus air. The exit cover is the same as the fan housing and the cut-outs are also the same.
Â
All filter fans are UL-approved and able to withstand the elements, including UV radiation.
Â
To help experience the capabilities of Z+F machines first-hand, we provide an in-depth demonstration and workshop. These sessions will show the machines in action and allow you to understand their features and gain valuable insight into their operation and benefits.
We are thrilled to announce the launch of IATECH, THe Industrial Automation Technology expo at Leicester Marriott Hotel on 23rd October. The ultimate platform for showcasing our extensive product range and broad business areas, featuring over 50 leading suppliers under one roof!
The specialist vehicle industry can include automotive and EV, heavy vehicles such as agriculture and rail, and marine. This email takes you through some of the various products we offer for specialist vehicle applications.
This blog post delves into the key components, current trends, and best practices in power distribution, illustrating the significant impact these systems have on our daily operations and long-term energy strategies.
We shine a spotlight on surge protection devices (SPDs), a crucial yet often overlooked component in industrial settings. Every surge of electricity, every fluctuation in voltage, poses a potential threat to your machinery and systems.
Renowned for high-quality cable cutting and crimping tools, Klauke serves electrical contractors, cable jointers, and linemen across a spectrum of sectors
|
|
|
|
|
||
---|---|---|---|---|---|---|
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
Parts | Air capacity | Air volume free blowing | Air volume free blowing with G3 filter | Number of fans | Sound level | Width | Height | Depth | Behind panel depth | Hole size | Weight | Materials fan | Material of rotor | Voltage max | Voltage min | Frequency | Power consumption | Power consumption | Life span | Storage temperature | Operational temperature | IP class | Approvals | Price | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
FF 018 Fan, 97 x 97 mm, 21m³/h, 230V ac, 50Hz, IP54
Art:
01800.0-00
Copied
|
21 m³/h
|
21 m³/h
|
16 m³/h
|
1
|
31 dB
|
129 mm
|
134 mm
|
80 mm
|
45 mm
|
97x97 mm
|
0,6 kg
|
Aluminium
|
Plastic
|
230 V ac
|
230 V ac
|
50 Hz
|
13 W
|
80 mA
|
50000 h
|
-40°C ... +70°C
|
-10°C ... +70°C
|
IP54, IP55
|
CE, cULus, EAC, RoHS, UL, UL E234324, UV - UL746C (f1), VDE
|
| ||
FF 018 Fan, 97 x 97 mm, 24m³/h, 100-120V ac, 60Hz, IP54
Art:
01800.0-01
Copied
|
24 m³/h
|
24 m³/h
|
18 m³/h
|
1
|
31 dB
|
129 mm
|
134 mm
|
80 mm
|
45 mm
|
97x97 mm
|
0,6 kg
|
Aluminium
|
Plastic
|
120 V ac
|
120 V ac
|
60 Hz
|
13 W
|
160 mA
|
50000 h
|
-40°C ... +70°C
|
-10°C ... +70°C
|
IP54, IP55
|
CE, cULus, EAC, RoHS, UL, UL E234324, UV - UL746C (f1)
|
| ||
EF 018 Fan, Exit filter, 97 x 97 mm cutout, IP54
Art:
11800.0-00
Copied
|
24 m³/h
|
24 m³/h
|
18 m³/h
|
|
|
129 mm
|
134 mm
|
80 mm
|
45 mm
|
97x97 mm
|
0,3 kg
|
|
|
|
|
|
|
|
|
-40°C ... +70°C
|
-10°C ... +70°C
|
IP54
|
CE, cULus, EAC, RoHS, UL, UL E234324, UV - UL746C (f1), VDE
|
| ||
FF 018 Fan, 125 x 125 mm, 55m³/h, 230V ac, 50Hz, IP54
Art:
01801.0-00
Copied
|
55 m³/h
|
55 m³/h
|
42 m³/h
|
1
|
40 dB
|
157 mm
|
170 mm
|
98 mm
|
58 mm
|
125x125 mm
|
1 kg
|
Aluminium
|
Plastic
|
230 V ac
|
230 V ac
|
50 Hz
|
15 W
|
100 mA
|
50000 h
|
-40°C ... +70°C
|
-10°C ... +70°C
|
IP54, IP55
|
CE, cULus, EAC, RoHS, UL, UL E234324, UV - UL746C (f1), VDE
|
| ||
FF 018 Fan, 125 x 125 mm, 63m³/h, 100-120V ac, 60Hz, IP54
Art:
01801.0-01
Copied
|
63 m³/h
|
63 m³/h
|
48 m³/h
|
1
|
40 dB
|
157 mm
|
170 mm
|
98 mm
|
58 mm
|
125x125 mm
|
1 kg
|
Aluminium
|
Plastic
|
120 V ac
|
120 V ac
|
60 Hz
|
15 W
|
180 mA
|
50000 h
|
-40°C ... +70°C
|
-10°C ... +70°C
|
IP54, IP55
|
CE, cULus, EAC, RoHS, UL, UL E234324, UV - UL746C (f1), VDE
|
| ||
EF 018 Fan, Exit filter, 125 x 125 mm cutout, IP54
Art:
11801.0-00
Copied
|
63 m³/h
|
63 m³/h
|
48 m³/h
|
|
|
157 mm
|
170 mm
|
98 mm
|
58 mm
|
125x125 mm
|
0,4 kg
|
|
|
|
|
|
|
|
|
-40°C ... +70°C
|
-10°C ... +70°C
|
IP54, IP55
|
CE, cULus, EAC, RoHS, UL, UL E234324, UV - UL746C (f1), VDE
|
| ||
FF 018 Fan, 176 x 176 mm², 102m³/h, 230V ac, 50Hz, IP54
Art:
01802.0-00
Copied
|
102 m³/h
|
102 m³/h
|
68 m³/h
|
1
|
39 dB
|
209 mm
|
226 mm
|
136 mm
|
86 mm
|
176x176 mm
|
1,3 kg
|
Aluminium
|
Plastic
|
230 V ac
|
230 V ac
|
50 Hz
|
15 W
|
100 mA
|
50000 h
|
-40°C ... +70°C
|
-10°C ... +70°C
|
IP54, IP55
|
CE, cULus, EAC, RoHS, UL, UL E234324, UV - UL746C (f1), VDE
|
| ||
FF 018 Fan, 176 x 176 mm², 117m³/h, 100-120V ac, 60Hz, IP54
Art:
01802.0-01
Copied
|
117 m³/h
|
117 m³/h
|
78 m³/h
|
1
|
39 dB
|
209 mm
|
226 mm
|
136 mm
|
86 mm
|
176x176 mm
|
1,3 kg
|
Aluminium
|
Plastic
|
120 V ac
|
120 V ac
|
60 Hz
|
15 W
|
180 mA
|
50000 h
|
-40°C ... +70°C
|
-10°C ... +70°C
|
IP54, IP55
|
CE, cULus, EAC, RoHS, UL, UL E234324, UV - UL746C (f1)
|
| ||
FF 018 Fan, 176 x 176 mm, 200m³/h, 230V ac, 50Hz, IP54
Art:
01804.0-00
Copied
|
200 m³/h
|
200 m³/h
|
125 m³/h
|
1
|
52 dB
|
209 mm
|
226 mm
|
145 mm
|
95 mm
|
176x176 mm
|
1,7 kg
|
Aluminium
|
Steel
|
230 V ac
|
230 V ac
|
50 Hz
|
45 W
|
320 mA
|
50000 h
|
-25°C ... +50°C
|
-25°C ... +50°C
|
IP54, IP55
|
CE, cULus, EAC, RoHS, UL, UL E234324, UV - UL746C (f1), VDE
|
| ||
FF 018 Fan, 176 x 176 mm, 230m³/h, 110-120V ac, 60Hz, IP54
Art:
01804.0-01
Copied
|
230 m³/h
|
230 m³/h
|
143 m³/h
|
1
|
39 dB
|
209 mm
|
226 mm
|
136 mm
|
86 mm
|
176x176 mm
|
1,7 kg
|
Aluminium
|
Steel
|
120 V ac
|
120 V ac
|
60 Hz
|
39 W
|
470 mA
|
50000 h
|
-25°C ... +60°C
|
-25°C ... +60°C
|
IP54, IP55
|
CE, cULus, EAC, RoHS, UL, UL E234324, UV - UL746C (f1)
|
| ||
EF 018 Fan, Exit filter, 176 x 176 mm cutout, IP54
Art:
11802.0-00
Copied
|
117 m³/h
|
117 m³/h
|
78 m³/h
|
|
|
209 mm
|
226 mm
|
136 mm
|
86 mm
|
176x176 mm
|
0,6 kg
|
|
|
|
|
|
|
|
|
-40°C ... +70°C
|
-10°C ... +70°C
|
IP54, IP55
|
CE, cULus, EAC, RoHS, UL, UL E234324, UV - UL746C (f1), VDE
|
| ||
FF 018 Fan, 250 x 250 mm, 300m³/h, 230V ac, 50Hz, IP54
Art:
01803.0-00
Copied
|
300 m³/h
|
300 m³/h
|
230 m³/h
|
4
|
56 dB
|
284 mm
|
284 mm
|
110 mm
|
65 mm
|
250x250 mm
|
3,3 kg
|
Aluminium
|
Plastic
|
230 V ac
|
230 V ac
|
50 Hz
|
68 W
|
400 mA
|
50000 h
|
-40°C ... +70°C
|
-10°C ... +70°C
|
IP54
|
CE, cULus, EAC, RoHS, UL, UL E234324, UV - UL746C (f1), VDE
|
| ||
FF 018 Fan, 250 x 250 mm, 345m³/h, 100-120V ac, 60Hz, IP54
Art:
01803.0-01
Copied
|
345 m³/h
|
345 m³/h
|
264 m³/h
|
4
|
56 dB
|
284 mm
|
284 mm
|
110 mm
|
65 mm
|
250x250 mm
|
3,3 kg
|
Aluminium
|
Plastic
|
120 V ac
|
120 V ac
|
60 Hz
|
68 W
|
800 mA
|
50000 h
|
-40°C ... +70°C
|
-10°C ... +70°C
|
IP54
|
CE, cULus, EAC, RoHS, UL, UL E234324, UV - UL746C (f1)
|
| ||
FF 018 Fan, 250 x 250 mm, 550m³/h, 230V ac, 50Hz, IP54
Art:
01805.0-00
Copied
|
550 m³/h
|
550 m³/h
|
300 m³/h
|
1
|
65 dB
|
284 mm
|
284 mm
|
152 mm
|
107 mm
|
250x250 mm
|
2,7 kg
|
Aluminium
|
Steel
|
230 V ac
|
230 V ac
|
50 Hz
|
64 W
|
300 mA
|
50000 h
|
-25°C ... +70°C
|
-25°C ... +70°C
|
IP54
|
CE, cULus, EAC, RoHS, UL, UL E234324, UV - UL746C (f1), VDE
|
| ||
FF 018 Fan, 250 x 250 mm, 632m³/h, 100-120V ac, 60Hz, IP54
Art:
01805.0-01
Copied
|
632 m³/h
|
632 m³/h
|
345 m³/h
|
1
|
65 dB
|
284 mm
|
284 mm
|
152 mm
|
107 mm
|
250x250 mm
|
2,7 kg
|
Aluminium
|
Steel
|
120 V ac
|
120 V ac
|
60
|
85 W
|
780 mA
|
50000 h
|
-25°C ... +70°C
|
-25°C ... +70°C
|
IP54
|
CE, cULus, EAC, RoHS, UL, UL E234324, UV - UL746C (f1)
|
| ||
EF 018 Fan, Exit filter, 250 x 250 mm cutout, IP54
Art:
11803.0-00
Copied
|
345 m³/h
|
345 m³/h
|
264 m³/h
|
|
|
284 mm
|
284 mm
|
67 mm
|
22 mm
|
250x250 mm
|
1 kg
|
|
|
|
|
|
|
|
|
-40°C ... +70°C
|
-10°C ... +70°C
|
IP54, IP55
|
CE, cULus, EAC, RoHS, UL, UL E234324, UV - UL746C (f1)
|
|
Select a variant in the list
If you need any help, you can contact us in one of the following ways: