PULS
The Puls Dimension DC-DC converter features high efficiency, very compact dimensions and mounting on DIN rail. The input voltage can come from, for example, a power supply unit, batteries or solar panels. The output is galvanically isolated from the input. Examples of fields application are installation at the end of a long cable to stabilize voltage, conversion of one voltage to another or for isolation of specific loads. The DC-DC converters are equipped with a soft-start function, entailing that the current gradually rises to the nominal value. In this way, high starting currents are avoided that can cause voltage drops on the primary side and produce start-up problems. A 20 % power boost provides additional power resources during temporary current peaks. Article CD5.241-S1 is equipped with status outputs for controlling both the output voltage and the input voltage.
Â
We recommend free space of 40 mm above the unit, 20 mm under and 5 mm at the sides.
Â
Input data |
|
---|---|
Input voltage dc | 24 V |
Input voltage dc min | 18 V DC |
Input voltage dc max | 32,4 V DC |
Input capacitance | 3000 µF |
Inrush current | Typ. 1,2 A @ 24 V DC |
Max entrance tripple | 5 V pp |
Output data |
|
Output voltage | 12 V DC |
Output voltage min | 12 V DC |
Output voltage max | 15 V DC |
Output current | 8 A |
Power | 96 W |
Efficiency / Lifetime / MTBF |
|
Efficiency | 88,2 % |
Life span | 63000 h @ 12 V DC, 8 A, 40 °C |
MTBF (IEC 61709) | 1161000 @ 12 V DC, 8 A, 40 °C |
Dimensions |
|
Width | 32 mm |
Height | 124 mm |
*Invisible Heading* |
|
---|---|
Depth | 102 mm |
Weight | 0,425 kg |
Other |
|
Approvals | ABS, ATEX, CB, CE, CSA, GL, IECEx, UL |
Keep time | Typ. 7 ms @ 24 V DC |
IP class | IP20 |
Clamp type | Screw on |
Material protection | Aluminium |
Ripple max | 75 mV pp |
Series | Dimension C |
Power drop from +60 °C to + 70 °C | 2,5 W/°C |
Temperature min without derating | -25 °C |
Temperature max without derating | 60 °C |
Startup delay | 420 ms |
Type Power Supply | DC-DC |
The Puls Dimension DC-DC converter features high efficiency, very compact dimensions and mounting on DIN rail. The input voltage can come from, for example, a power supply unit, batteries or solar panels. The output is galvanically isolated from the input. Examples of fields application are installation at the end of a long cable to stabilize voltage, conversion of one voltage to another or for isolation of specific loads. The DC-DC converters are equipped with a soft-start function, entailing that the current gradually rises to the nominal value. In this way, high starting currents are avoided that can cause voltage drops on the primary side and produce start-up problems. A 20 % power boost provides additional power resources during temporary current peaks. Article CD5.241-S1 is equipped with status outputs for controlling both the output voltage and the input voltage.
Â
We recommend free space of 40 mm above the unit, 20 mm under and 5 mm at the sides.
Â
|
|
|
|
|
||
---|---|---|---|---|---|---|
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
Parts | Input voltage dc min | Output voltage | Output voltage min | Output voltage max | Output current | Power | Efficiency | Life span | MTBF (IEC 61709) | Weight | Approvals | Keep time | Clamp type | Ripple max | Status output | Power drop from +60 °C to + 70 °C | Temperature max without derating | Startup delay | DC relay output | Price | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
PSU 24V dc I/P 12V dc 8A 96W O/P
Art:
CD5.121
Copied
|
18 V DC
|
12 V DC
|
12 V DC
|
15 V DC
|
8 A
|
96 W
|
88,2 %
|
63000 h @ 12 V DC, 8 A, 40 °C
|
1161000 @ 12 V DC, 8 A, 40 °C
|
0,425 kg
|
ABS, ATEX, CB, CE, CSA, GL, IECEx, UL
|
Typ. 7 ms @ 24 V DC
|
Screw on
|
75 mV pp
|
|
2,5 W/°C
|
60 °C
|
420 ms
|
|
| ||
PSU 24V dc I/P 24V dc 5A 120W O/P
Art:
CD5.241
Copied
|
18 V DC
|
24 V DC
|
24 V DC
|
28 V DC
|
5 A
|
120 W
|
90,3 %
|
65000 h @ 24 V DC, 5 A, 40 °C
|
1178000 @ 24 V DC, 5 A, 40 °C
|
0,425 kg
|
ABS, ATEX, CB, CE, CSA, GL, IECEx, UL
|
Typ. 6 ms @ 24 V DC
|
Screw on
|
50 mV pp
|
|
3 W/°C
|
60 °C
|
650 ms
|
|
| ||
PSU 24V dc I/P 24V dc 3.8A 92W O/P NEC-CLASS-2
Art:
CD5.241-L1
Copied
|
14,4 V DC
|
24 V DC
|
24 V DC
|
24,1 V DC
|
3,8 A
|
92 W
|
90,5 %
|
134000 h @ 24 V DC, 3,8 A, 40 °C
|
1487000 h @ 24 V DC, 3,8 A, 40 °C
|
0,425 kg
|
ABS, ATEX, CB, CE, CSA, GL, IECEx, NEC Class 2, UL
|
Typ. 7 ms @ 24 V DC
|
Spring-clamp
|
50 mV pp
|
|
0 W/°C
|
70 °C
|
290 ms
|
|
| ||
PSU 24V dc I/P 24V dc 5A 120W O/P DC-OK Input-Low contacts
Art:
CD5.241-S1
Copied
|
18 V DC
|
24 V DC
|
24 V DC
|
28 V DC
|
5 A
|
120 W
|
90,2 %
|
60000 h @ 24 V DC, 5 A, 40 °C
|
1048000 @ 24 V DC, 5 A, 40 °C
|
0,45 kg
|
ABS, ATEX, CB, CE, CSA, GL, IECEx, UL
|
Typ. 6 ms @ 24 V DC
|
Spring-clamp
|
50 mV pp
|
DC-OK and Input-Low
|
3 W/°C
|
60 °C
|
650 ms
|
Yes
|
|